FCC ID YAMZ1PF4

TETRA Terminal

by Hytera Communications Corporation Limited

Grantee Code: YAM   Product Code: Z1PF4
Latest application date: 2016-06-22

Device Images

FCC ID Device Details

FCC IDYAMZ1PF4
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeYAM
Product CodeZ1PF4
Applicant BusinessHytera Communications Corporation Limited 🇨🇳
Related Domains hytera.com
Equipment ClassTETRA Terminal
Test FirmBay Area Compliance Laboratories Corp. (Dongguan)

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2016-06-22
2402-2480 MHzOriginal Equipment2016-06-22
450-470 MHzOriginal Equipment2016-06-22

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2016-06-22PDF 2.7 MB
Users ManualUsers Manual2016-06-22PDF 2.7 MB
Int PhotosInternal Photos2016-06-22PDF 811.7 KB
Ext PhotosExternal Photos2016-06-22PDF 740.7 KB
FCC ID LabelID Label/Location Info2016-06-22PDF 246.5 KB
Setup PhotosTest Setup Photos2016-06-22PDF 268.7 KB
Test ReportTest Report2016-06-22PDF 1,010.8 KB
Test ReportTest Report2016-06-22PDF 492 KB
Test ReportTest Report2016-06-22PDF 1,000.5 KB
Confidentiality LetterCover Letter(s)2016-06-22PDF 26.4 KB
Frequency Justification LetterCover Letter(s)2016-06-22PDF 19.9 KB
POACover Letter(s)2016-06-22PDF 18.8 KB
SAR ReportRF Exposure Info2016-06-22PDF 2.4 MB
Block Diagram Metadata onlyBlock DiagramPDF 19.4 KB
Schematics Metadata onlySchematicsPDF 421.4 KB
Operation Description Metadata onlyOperational DescriptionPDF 370.5 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 73.2 KB
Tune up Procedure Metadata onlyParts List/Tune Up InfoPDF 125.2 KB

Application Information

Application IDtrIMiH/qC/xVhrPzAHJLGg==
Final Action Date2016-06-22
Application PurposeOriginal Equipment
Applicant FRN0019701887
ModelZ1PF4
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionTETRA Terminal
Responsible PartyTiantian Chen, Certification Engineer, tiantian.chen@hytera.com , +86-755-26972999
Test FirmJohn Chan, Bay Area Compliance Laboratories Corp. (Dongguan), john.chan@baclcorp.com , 86-769-86858888
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted.

Applications

Application IDDatePurpose
trIMiH/qC/xVhrPzAHJLGg==2016-06-22Original Equipment
jTbH15TdiJznSYjx7n5p1Q==2016-06-22Original Equipment
63d5TEiM2UABbAYq2+hd/Q==2016-06-22Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
450-470 MHz3.00000002.5000000000ppm20K2GXW90EF
2402-2480 MHz0.005000015C
2402-2480 MHz0.006000015C

Grants

TCB Grant - Application trIMiH/qC/xVhrPzAHJLGg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 06/22/2016

Application Dated: 06/22/2016
Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North,
9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMZ1PF4
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: TETRA Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.006  

Output power listed is conducted.

EAS Grant - Application trIMiH/qC/xVhrPzAHJLGg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
  Date of Grant: 06/22/2016

Application Dated: 06/22/2016
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMZ1PF4
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: TETRA Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.006  

Output power listed is conducted.



TCB Grant - Application jTbH15TdiJznSYjx7n5p1Q==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 06/22/2016

Application Dated: 06/22/2016
Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North,
9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMZ1PF4
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Digital Transmission System
Notes: TETRA Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.005  

Output power listed is conducted.

EAS Grant - Application jTbH15TdiJznSYjx7n5p1Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
  Date of Grant: 06/22/2016

Application Dated: 06/22/2016
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMZ1PF4
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Digital Transmission System
Notes: TETRA Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.005  

Output power listed is conducted.



TCB Grant - Application 63d5TEiM2UABbAYq2+hd/Q==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 06/22/2016

Application Dated: 06/22/2016
Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North,
9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMZ1PF4
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: TETRA Terminal
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EF 90 450.0  -  470.0 3.0 2.5  PM 20K2GXW

Power output listed is conducted. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip/holster/accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for Face-held, body-worn accessories and simultaneous transmission conditions are 1.30 W/kg, 1.58 W/kg, and 1.84 W/kg, respectively at 50% duty factor.

EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

EAS Grant - Application 63d5TEiM2UABbAYq2+hd/Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hytera Communications Corporation Limited
Hytera Tower, Hi-Tech Industrial Park North, 9108# Beihuan Road, Nanshan District,
Shenzhen, 518057
China
  Date of Grant: 06/22/2016

Application Dated: 06/22/2016
 
Attention: Tiantian Chen , Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YAMZ1PF4
Name of Grantee:  Hytera Communications Corporation Limited
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: TETRA Terminal
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EF 90 450.0  -  470.0 3.0 2.5  PM 20K2GXW

Power output listed is conducted. This device must be restricted to work-related operations only in an Occupational/Controlled RF exposure environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational/Controlled Exposure limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip/holster/accessories tested for this filing. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for Face-held, body-worn accessories and simultaneous transmission conditions are 1.30 W/kg, 1.58 W/kg, and 1.84 W/kg, respectively at 50% duty factor.


EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

Mail To: