FCC ID YCVBRHA02

HANDHELD MOBILE TELEMETRY DEVICE

by Biomedical Systems Corporation

Grantee Code: YCV   Product Code: BRHA02
Latest application date: 2012-05-16

FCC ID Device Details

FCC IDYCVBRHA02
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeYCV
Product CodeBRHA02
Applicant BusinessBiomedical Systems Corporation 🇺🇸
Related Domains biomedsys.com
Equipment ClassHANDHELD MOBILE TELEMETRY DEVICE
Test FirmCETECOM Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2012-05-16
2402-2480 MHzOriginal Equipment2012-05-16

Exhibits

DocumentTypeAvailableFile
Operations ManualUsers Manual2012-05-16PDF 3.4 MB
Internal PhotosInternal Photos2012-05-16PDF 1.3 MB
Internal PhotosInternal Photos2012-05-16PDF 966.4 KB
External PhotosExternal Photos2012-05-16PDF 3.6 MB
Label ArtworkID Label/Location Info2012-05-16PDF 337 KB
Test Setup PhotosTest Setup Photos2012-05-16PDF 1.8 MB
Module Test ReportTest Report2012-05-16PDF 529.8 KB
Test ReportTest Report2012-05-16PDF 821 KB
Test Report 24Test Report2012-05-16PDF 313.5 KB
Attestation LetterCover Letter(s)2012-05-16PDF 78.4 KB
Authorization LetterCover Letter(s)2012-05-16PDF 13.2 KB
Confidential LetterCover Letter(s)2012-05-16PDF 78.3 KB
FCC StatementCover Letter(s)2012-05-16PDF 134.2 KB
POACover Letter(s)2012-05-16PDF 30.4 KB
SAR Appendix ARF Exposure Info2012-05-16PDF 1.5 MB
SAR Appendix BRF Exposure Info2012-05-16PDF 327.3 KB
SAR Appendix CRF Exposure Info2012-05-16PDF 5.1 MB
SAR ReportRF Exposure Info2012-05-16PDF 435.7 KB

Application Information

Application IDQpgZDeuJfeDpIfOyNly/Jg==
Final Action Date2012-05-16
Application PurposeOriginal Equipment
Applicant FRN0019638865
ModelBRHA02
Frequency Range824.2-848.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionHANDHELD MOBILE TELEMETRY DEVICE
Responsible PartyKenneth Michael Kroehnke, Director of Quality Management, kmk@biomedsys.com , 314-576-6800
Test FirmFranz Engert, CETECOM Inc., franz.engert@cetecom.com , 408-586-6249
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is EIRP for part 24 and ERP for part 22. For body-worn operation, this phone has been tested and meets the FCC RF exposure guidelines when used with a Biomedical Systems Corporation accessory designated for this product. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn accessory, are 0.79W/kg, and 1.27W/kg, respectively. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations.

Applications

Application IDDatePurpose
QpgZDeuJfeDpIfOyNly/Jg==2012-05-16Original Equipment
FwiNXJ1FeaxIpjwkW455cg==2012-05-16Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz2.1773Hz247KGXW22H
824.2-848.8 MHz0.5373Hz240KG7W22H
1850.2-1909.8 MHz1.3179Hz245KGXW24E
1850.2-1909.8 MHz0.8979Hz238KG7W24E
2402-2480 MHz0.017000015C

Grants

TCB Grant - Application QpgZDeuJfeDpIfOyNly/Jg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 05/16/2012

Application Dated: 05/16/2012
Biomedical Systems Corporation
77 Progress Parkway
St. Louis, MO 63043
 
Attention: Kenneth Kroehnke , Director of Quality Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YCVBRHA02
Name of Grantee:  Biomedical Systems Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: HANDHELD MOBILE TELEMETRY DEVICE
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 2.17 73.0  Hz 247KGXW
22H 824.2  -  848.8 0.53 73.0  Hz 240KG7W
24E 1850.2  -  1909.8 1.31 79.0  Hz 245KGXW
24E 1850.2  -  1909.8 0.89 79.0  Hz 238KG7W

Power listed is EIRP for part 24 and ERP for part 22. For body-worn operation, this phone has been tested and meets the FCC RF exposure guidelines when used with a Biomedical Systems Corporation accessory designated for this product. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn accessory, are 0.79W/kg, and 1.27W/kg, respectively. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations.

EAS Grant - Application QpgZDeuJfeDpIfOyNly/Jg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Biomedical Systems Corporation
77 Progress Parkway P.O. Box ,
St. Louis, MO 63043
United States
  Date of Grant: 05/16/2012

Application Dated: 05/16/2012
 
Attention: Kenneth Kroehnke , Director of Quality Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YCVBRHA02
Name of Grantee:  Biomedical Systems Corporation
Equipment Class: PCS Licensed Transmitter held to ear
Notes: HANDHELD MOBILE TELEMETRY DEVICE
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 2.17 73.0  Hz 247KGXW
22H 824.2  -  848.8 0.53 73.0  Hz 240KG7W
24E 1850.2  -  1909.8 1.31 79.0  Hz 245KGXW
24E 1850.2  -  1909.8 0.89 79.0  Hz 238KG7W

Power listed is EIRP for part 24 and ERP for part 22. For body-worn operation, this phone has been tested and meets the FCC RF exposure guidelines when used with a Biomedical Systems Corporation accessory designated for this product. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn accessory, are 0.79W/kg, and 1.27W/kg, respectively. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations.



TCB Grant - Application FwiNXJ1FeaxIpjwkW455cg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45 <BR>P.O. Box 370,
Newberry, FL 32669
Date of Grant: 05/16/2012

Application Dated: 05/16/2012
Biomedical Systems Corporation
77 Progress Parkway
St. Louis, MO 63043
 
Attention: Kenneth Kroehnke , Director of Quality Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YCVBRHA02
Name of Grantee:  Biomedical Systems Corporation
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: HANDHELD MOBILE TELEMETRY DEVICE
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.017  

Power listed is conducted.

EAS Grant - Application FwiNXJ1FeaxIpjwkW455cg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Biomedical Systems Corporation
77 Progress Parkway P.O. Box ,
St. Louis, MO 63043
United States
  Date of Grant: 05/16/2012

Application Dated: 05/16/2012
 
Attention: Kenneth Kroehnke , Director of Quality Management

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YCVBRHA02
Name of Grantee:  Biomedical Systems Corporation
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: HANDHELD MOBILE TELEMETRY DEVICE
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.017  

Power listed is conducted.



Mail To: