FCC ID YHLBLUCLICKLIT

Mobile phone

by BLU Products, Inc.

Grantee Code: YHL   Product Code: BLUCLICKLIT
Latest application date: 2012-05-16

FCC ID Device Details

FCC IDYHLBLUCLICKLIT
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeYHL
Product CodeBLUCLICKLIT
Applicant BusinessBLU Products, Inc. 🇺🇸
Related Domains ctasiasz.com sporton.com.tw
Equipment ClassMobile phone
Test FirmSPORTON International Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2012-05-16

Exhibits

DocumentTypeAvailableFile
user manual revUsers Manual2012-11-09PDF 410.6 KB
internal photoInternal Photos2012-11-09PDF 1.2 MB
external photoExternal Photos2012-11-09PDF 717.5 KB
ID LabelID Label/Location Info2012-05-16PDF 46.8 KB
Labe location infoID Label/Location Info2012-05-16PDF 67.2 KB
RF test setup photoTest Setup Photos2012-11-09PDF 457.7 KB
SAR test setup photoTest Setup Photos2012-11-09PDF 925.6 KB
test reportTest Report2012-05-16PDF 798.2 KB
Declaration letterCover Letter(s)2012-05-16PDF 11.6 KB
declaration letterCover Letter(s)2012-05-16PDF 141.3 KB
declaration of authorizationCover Letter(s)2012-05-16PDF 35.9 KB
long term confidentialityCover Letter(s)2012-05-16PDF 59.4 KB
short term confidentialityCover Letter(s)2012-05-16PDF 28.7 KB
RF exposure infoRF Exposure Info2012-05-16PDF 3.6 MB
RF exposure infoParts List/Tune Up Info2012-05-16PDF 2.5 MB

Application Information

Application IDjLFBwX5tz01jW4lUP2LpzQ==
Final Action Date2012-05-16
Application PurposeOriginal Equipment
Applicant FRN0019890946
ModelBLUCLICKLIT
Frequency Range824.2-848.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionMobile phone
Responsible PartyJones Chen, Certification manager, ChenJ@ctasiasz.com , 3057157171
Technical ContactMichael Lin, Sporton International (Kunshan) Inc. - China, Michael@sporton.com.tw , +86-0512-5790-0158
Non-Technical ContactMichael Lin, Sporton International (Kunshan) Inc. - China, Michael@sporton.com.tw
Test FirmAlex Chen, SPORTON International Inc., alex@sporton.com.tw , 886-2-26962468
TCB Emailcertification@telefication.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date11/09/2012
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower Output is ERP for Part 22 and EIRP for Part 24. SAR compliance for bodyworn operating conditions is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user's body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance.The highest reported SAR values are: Head: 1.14 W/kg; Body-worn:0.33 W/kg.

Applications

Application IDDatePurpose
jLFBwX5tz01jW4lUP2LpzQ==2012-05-16Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz0.340.05ppm246KGXW22H
1850.2-1909.8 MHz0.860.06ppm248KGXW24E

Grants

TCB Grant - Application jLFBwX5tz01jW4lUP2LpzQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Telefication B.V.
Edisonstraat 12a
Zevenaar, NL-6902 PK
Netherlands
Date of Grant: 05/16/2012

Application Dated: 05/13/2012
CT Asia
Unit1309-11,13th Floor 9 Wing Hong Street
Cheung Sha Wan Kowloon
Kowloon, 999077
Hong Kong
 
Attention: Jones Chen , Certification manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YHLBLUCLICKLIT
Name of Grantee:  CT Asia
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Mobile phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.34 0.05  PM 246KGXW
24E 1850.2  -  1909.8 0.86 0.06  PM 248KGXW

Power Output is ERP for Part 22 and EIRP for Part 24. SAR compliance for bodyworn operating conditions is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user's body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance.The highest reported SAR values are: Head: 1.14 W/kg; Body-worn:0.33 W/kg.

EAS Grant - Application jLFBwX5tz01jW4lUP2LpzQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

CT Asia
Unit1309-11,13th Floor 9 Wing Hong Street Cheung Sha Wan Kowloon
Kowloon, 999077
Hong Kong
  Date of Grant: 05/16/2012

Application Dated: 05/13/2012
 
Attention: Jones Chen , Certification manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YHLBLUCLICKLIT
Name of Grantee:  CT Asia
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Mobile phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.34 0.05  PM 246KGXW
24E 1850.2  -  1909.8 0.86 0.06  PM 248KGXW

Power Output is ERP for Part 22 and EIRP for Part 24. SAR compliance for bodyworn operating conditions is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user's body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance.The highest reported SAR values are: Head: 1.14 W/kg; Body-worn:0.33 W/kg.



Mail To: