FCC ID YL6-143P100

EZ Point

by Alarm.com Incorporated

Grantee Code: YL6   Product Code: 143P100
Latest application date: 2025-09-19

FCC ID Device Details

FCC IDYL6-143P100
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeYL6
Product Code143P100
Applicant BusinessAlarm.com Incorporated 🇺🇸
Related Domains alarm.com
Equipment ClassEZ Point
Test FirmSporton International Inc. Hsinhua Laboratory

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
912-920 MHzOriginal Equipment2025-09-19
916 MHzOriginal Equipment2025-09-19

Exhibits

DocumentTypeAvailableFile
YL6-143P100_UMUsers Manual2026-03-19PDF 234 KB
YL6-143P100_Ant info._0917Internal Photos2026-03-19PDF 334.4 KB
YL6-143P100_InPhoInternal Photos2026-03-19PDF 4.4 MB
YL6-143P100_ExPhoExternal Photos2026-03-19PDF 4.4 MB
YL6-143P100_Label_ADC-EZ100-USID Label/Location Info2025-09-19PDF 609.8 KB
YL6-143P100_Label_ADC-EZ100P-USID Label/Location Info2025-09-19PDF 599.8 KB
YL6-143P100_Test Sup_15.247Test Setup Photos2026-03-19PDF 1.3 MB
YL6-143P100_Test Sup_15.249Test Setup Photos2026-03-19PDF 1.3 MB
YL6-143P100_Ant spec._0917Test Report2025-09-19PDF 358.2 KB
YL6-143P100_Test Rpt_15.247Test Report2025-09-19PDF 2.9 MB
YL6-143P100_Test Rpt_15.249 Metadata onlyTest Report2025-09-19PDF 2.7 MB
YL6-143P100_Test Rpt_15.249_0919Test Report2025-09-19PDF 2.9 MB
YL6-143P100_Attestation_2.911(d)(5)Attestation Statements2025-09-19PDF 376.7 KB
YL6-143P100_Attestation_2.911(d)(5)_0924Attestation Statements2025-09-19PDF 355 KB
YL6-143P100_Attestation_2.911(d)(7)Attestation Statements2025-09-19PDF 549.4 KB
YL6-143P100_Confidentiality_STCCover Letter(s)2025-09-19PDF 471.5 KB
YL6-143P100_LoACover Letter(s)2025-09-19PDF 658.5 KB
YL6-143P100_Model Difference DeclarationCover Letter(s)2025-09-19PDF 272.9 KB
YL6-143P100_Test Rpt_MPERF Exposure Info2025-09-19PDF 302.2 KB
YL6-143P100_Blk Metadata onlyBlock DiagramPDF 218.1 KB
YL6-143P100_Schem Metadata onlySchematicsPDF 1.8 MB
YL6-143P100_OpDesc_FCC Metadata onlyOperational DescriptionPDF 50.5 KB

Application Information

Application IDxV5N8k+a0gWoiExhknqj8Q==
Final Action Date2025-09-19
Application PurposeOriginal Equipment
Applicant FRN0020041976
Model143P100
Frequency Range912-920 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionEZ Point
Responsible PartyDaniel Ramos, dramos@alarm.com , 877-389-4033
Test FirmAlex Chen, Sporton International Inc. Hsinhua Laboratory, alex@sporton.com.tw , 886-3-327-3456
TCB EmailQA65@sporton-usa.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
xV5N8k+a0gWoiExhknqj8Q==2025-09-19Original Equipment
isvJdaZ1E+OQegdV0OiBxg==2025-09-19Original Equipment

Equipment Authorization

FrequencyOutputRules
912-920 MHz0.075715C
908.4 MHz15C
916 MHz15C

Grants

TCB Grant - Application xV5N8k+a0gWoiExhknqj8Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Sporton International (USA) Inc.
1175 Montague Expressway
Milpitas, CA 95035
Date of Grant: 09/19/2025

Application Dated: 09/18/2025
Alarm.com Incorporated
8281 Greensboro Drive
Suite 100
Tysons, VA 22102
 
Attention: Daniel Ramos , Senior VP, Corporate Development

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YL6-143P100
Name of Grantee:  Alarm.com Incorporated
Equipment Class: Digital Transmission System
Notes: EZ Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 912.0  -  920.0 0.0757  

Output power listed is conducted. The antenna(s) used for this device must be installed to provide a separation distance of at least 20 cm from all persons. Co-location of this device with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. End-users must be provided with transmitter operating instructions for satisfying RF exposure compliance.

TCB Grant - Application isvJdaZ1E+OQegdV0OiBxg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Sporton International (USA) Inc.
1175 Montague Expressway
Milpitas, CA 95035
Date of Grant: 09/19/2025

Application Dated: 09/18/2025
Alarm.com Incorporated
8281 Greensboro Drive
Suite 100
Tysons, VA 22102
 
Attention: Daniel Ramos , Senior VP, Corporate Development

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YL6-143P100
Name of Grantee:  Alarm.com Incorporated
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: EZ Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 908.4  -  908.4  
15C 916.0  -  916.0  

The antenna(s) used for this device must be installed to provide a separation distance of at least 20 cm from all persons. Co-location of this device with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. End-users must be provided with transmitter operating instructions for satisfying RF exposure