FCC ID YOM-VSCANAIRSL
Vscan Air SL
by GE Healthcare
Grantee Code: YOM Product Code: VSCANAIRSL
Latest application date: 2023-04-17
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5745-5825 MHz | Original Equipment | 2023-04-17 |
| 2412-2462 MHz | Original Equipment | 2023-04-17 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual_Part 1 | Users Manual | 2023-10-15 | PDF 2.9 MB |
| User Manual_Part 2 | Users Manual | 2023-10-15 | PDF 4.1 MB |
| Justification Letter for confidentiality of internal photos | Cover Letter(s) | 2023-04-17 | PDF 51.6 KB |
| External Photos | External Photos | 2023-10-15 | PDF 297.6 KB |
| ID Label and Location | ID Label/Location Info | 2023-04-17 | PDF 126.3 KB |
| Test Setup Photos | Test Setup Photos | 2023-10-15 | PDF 620.5 KB |
| SAR Test Report | RF Exposure Info | 2023-04-17 | PDF 3.7 MB |
| SAR Test Report_Appendix A Plots for SAR measurements | RF Exposure Info | 2023-04-17 | PDF 571.7 KB |
| SAR Test Report_Appendix B System performance check | RF Exposure Info | 2023-04-17 | PDF 435.8 KB |
| SAR Test Report_Appendix C Calibration certificate for Probe and Dipole | RF Exposure Info | 2023-04-17 | PDF 2.6 MB |
| Test Report_2.4G WLAN and BLE_Part 1 | Test Report | 2023-04-17 | PDF 4.1 MB |
| Test Report_2.4G WLAN and BLE_Part 2 | Test Report | 2023-04-17 | PDF 3.9 MB |
| Test Report_5G WLAN_Part 1 | Test Report | 2023-04-17 | PDF 2.5 MB |
| Test Report_5G WLAN_Part 2 | Test Report | 2023-04-17 | PDF 4 MB |
| Attestation_Not Covered Entity Applicant | Attestation Statements | 2023-04-17 | PDF 55.7 KB |
| Attestation_Not Covered Equipment | Attestation Statements | 2023-04-17 | PDF 54.6 KB |
| Designating a US Agent | Attestation Statements | 2023-04-17 | PDF 1.2 MB |
| Agency Letter | Cover Letter(s) | 2023-04-17 | PDF 730 KB |
| Agent Authorization letter | Cover Letter(s) | 2023-04-17 | PDF 730 KB |
| Antenna Gain Info | Cover Letter(s) | 2023-04-17 | PDF 1.5 MB |
| Confidentiality Letter | Cover Letter(s) | 2023-04-17 | PDF 681.6 KB |
| Justification Letter for confidentiality Letter | Cover Letter(s) | 2023-04-17 | PDF 51.6 KB |
| Internal Photos Metadata only | Internal Photos | PDF 459.8 KB | |
| Block Diagram Metadata only | Block Diagram | PDF 363.3 KB | |
| Schematics Metadata only | Schematics | PDF 1.2 MB | |
| Operational Description Metadata only | Operational Description | PDF 2 MB | |
| Operational Description_Software Security Info Metadata only | SDR Software/Security Inf | PDF 93.8 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 354 KB |
Application Information
| Application ID | GmiTiTW9qvr77TlA1l0fGA== |
|---|---|
| Final Action Date | 2023-04-17 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0020092292 |
| Model | VSCANAIRSL |
| Frequency Range | 5745-5825 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | Vscan Air SL |
| Responsible Party | Gunaseelan Murugan, guna.m@ge.com |
| Technical Contact | Gunaseelan Murugan, GE Vingmed Ultrasound AS, guna.m@ge.com |
| Test Firm | B R Guruprasad, TUV Rheinland (India) Pvt. Ltd., guruprasad.br@ind.tuv.com |
| TCB Email | tcb-hotline@tuv.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 10/15/2023 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted. This device is a handheld ultrasound wireless probe. The highest 10-g extremity SAR and 1-g Body SAR are 1.55W/kg and 0.33W/kg respectively. It supports 20MHz and 40MHz bandwidth. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| GmiTiTW9qvr77TlA1l0fGA== | 2023-04-17 | Original Equipment |
| 7t7ohX9VHfrMIxw7PoROxw== | 2023-04-17 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application GmiTiTW9qvr77TlA1l0fGA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV Rheinland of North America, Inc. 1279 Quarry Lane Suite A Pleasanton, CA 94566 |
Date of Grant: 04/17/2023 Application Dated: 04/17/2023 |
| GE Healthcare |
| John F Welch Technology Center |
| Odyssey, #122, EPIP Phase II, Whitefield |
| Bangalore, 560066 India |
| Attention: Gunaseelan Murugan |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YOM-VSCANAIRSL |
| Name of Grantee: | GE Healthcare |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Vscan Air SL |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0185 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.0094 |
| Output power listed is conducted. This device is a handheld ultrasound wireless probe. The highest 10-g extremity SAR and 1-g Body SAR are 1.55W/kg and 0.33W/kg respectively. It supports 20MHz and 40MHz bandwidth. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application GmiTiTW9qvr77TlA1l0fGA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
GE Healthcare John F Welch Technology Center Odyssey, #122, EPIP Phase II, Whitefield Bangalore, 560066 India |
Date of Grant: 04/17/2023 Application Dated: 04/17/2023 |
| Attention: Gunaseelan Murugan |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YOM-VSCANAIRSL |
| Name of Grantee: | GE Healthcare |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Vscan Air SL |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0185 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.0094 |
| Output power listed is conducted. This device is a handheld ultrasound wireless probe. The highest 10-g extremity SAR and 1-g Body SAR are 1.55W/kg and 0.33W/kg respectively. It supports 20MHz and 40MHz bandwidth. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
TUV Rheinland of North America, Inc. 1279 Quarry Lane Suite A Pleasanton, CA 94566 |
Date of Grant: 04/17/2023 Application Dated: 04/17/2023 |
| GE Healthcare |
| John F Welch Technology Center |
| Odyssey, #122, EPIP Phase II, Whitefield |
| Bangalore, 560066 India |
| Attention: Gunaseelan Murugan |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YOM-VSCANAIRSL |
| Name of Grantee: | GE Healthcare |
| Equipment Class: | Digital Transmission System |
| Notes: | Vscan Air SL |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.0285 | ||
| CC | 15C | 2402.0 - 2480.0 | 0.0037 |
| Output power listed is conducted. This device is a handheld ultrasound wireless probe. The highest 10-g extremity SAR and 1-g Body SAR are 0.35W/kg and 0.11W/kg respectively. It supports 20MHz and 40MHz bandwidth. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application 7t7ohX9VHfrMIxw7PoROxw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
GE Healthcare John F Welch Technology Center Odyssey, #122, EPIP Phase II, Whitefield Bangalore, 560066 India |
Date of Grant: 04/17/2023 Application Dated: 04/17/2023 |
| Attention: Gunaseelan Murugan |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YOM-VSCANAIRSL |
| Name of Grantee: | GE Healthcare |
| Equipment Class: | Digital Transmission System |
| Notes: | Vscan Air SL |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.0285 | ||
| CC | 15C | 2402.0 - 2480.0 | 0.0037 |
| Output power listed is conducted. This device is a handheld ultrasound wireless probe. The highest 10-g extremity SAR and 1-g Body SAR are 0.35W/kg and 0.11W/kg respectively. It supports 20MHz and 40MHz bandwidth. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |