FCC ID YST-NX15
Wireless Smoke / Heat / CO Alarm
by Exigent Sensors LLC
Grantee Code: YST Product Code: NX15
Latest application date: 2013-11-07
FCC ID Device Details
| FCC ID | YST-NX15 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | YST |
| Product Code | NX15 |
| Applicant Business | Exigent Sensors LLC 🇺🇸 |
| Related Domains | |
| Equipment Class | Wireless Smoke / Heat / CO Alarm |
| Test Firm | Nemko USA, Inc. - San Diego EMC Division |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 905.2 MHz | Original Equipment | 2013-11-07 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2013-11-07 | PDF 2 MB |
| Internal Photo | Internal Photos | 2013-11-07 | PDF 112.8 KB |
| External Photos | External Photos | 2013-11-07 | PDF 61.7 KB |
| Label and Label Location | ID Label/Location Info | 2013-11-07 | PDF 321.3 KB |
| Test Setup Photos | Test Setup Photos | 2013-11-07 | PDF 1.1 MB |
| Test Report | Test Report | 2013-11-07 | PDF 704.7 KB |
| Cover Letters | Cover Letter(s) | 2013-11-07 | PDF 313.1 KB |
| RF Exposure info | RF Exposure Info | 2013-11-07 | PDF 47.2 KB |
Application Information
| Application ID | uEsttkJWy9PlvezZ5Y228Q== |
|---|---|
| Final Action Date | 2013-11-07 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0020201190 |
| Model | -NX15 |
| Frequency Range | 905.2 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Wireless Smoke / Heat / CO Alarm |
| Responsible Party | Chad David Christensen, Electrical Engineer, CCHRISTENSEN@EXIGENTSENSORS.COM |
| Test Firm | Jim Morris, Nemko USA, Inc. - San Diego EMC Division, Jim.Morris@nemko.com |
| TCB Email | Stuart.Beck@nemko.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is peak conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| uEsttkJWy9PlvezZ5Y228Q== | 2013-11-07 | Original Equipment |
Grants
TCB Grant - Application uEsttkJWy9PlvezZ5Y228Q==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko Canada Inc. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 11/07/2013 Application Dated: 11/07/2013 |
| Exigent Sensors LLC |
| 11331 Markon Dr |
| Garden Grove, CA 92841 |
| Attention: Chad Christensen , Electrical Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YST-NX15 |
| Name of Grantee: | Exigent Sensors LLC |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless Smoke / Heat / CO Alarm |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 905.2 - 905.2 | 0.007 | |||
| 15C | 913.2 - 913.2 | 0.007 |
| Power listed is peak conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
EAS Grant - Application uEsttkJWy9PlvezZ5Y228Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Exigent Sensors LLC 11331 Markon Dr P.O. Box , Garden Grove, CA 92841 United States |
Date of Grant: 11/07/2013 Application Dated: 11/07/2013 |
| Attention: Chad Christensen , Electrical Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YST-NX15 |
| Name of Grantee: | Exigent Sensors LLC |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless Smoke / Heat / CO Alarm |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 905.2 - 905.2 | 0.007 | |||
| 15C | 913.2 - 913.2 | 0.007 |
| Power listed is peak conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| Mail To: |