FCC ID YV8-DA1101
802.11n In-Wall / Ceiling Wireless Access Point
by Pass & Seymour, Inc. d/b/a Legrand
Grantee Code: YV8 Product Code: DA1101
Latest application date: 2013-07-11
FCC ID Device Details
| FCC ID | YV8-DA1101 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | YV8 |
| Product Code | DA1101 |
| Applicant Business | Pass & Seymour, Inc. d/b/a Legrand 🇺🇸 |
| Related Domains | |
| Equipment Class | 802.11n In-Wall / Ceiling Wireless Access Point |
| Test Firm | Worldwide Testing Services (Taiwan) Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Class II permissive change or modification of presently authorized equipment | 2013-07-11 |
| 2412-2462 MHz | Original Equipment | 2011-11-07 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2013-07-11 | PDF 3.6 MB |
| Users Manual | Users Manual | 2011-11-07 | PDF 4.7 MB |
| Internal Photos | Internal Photos | 2013-07-11 | PDF 943.7 KB |
| Internal Photos | Internal Photos | 2011-11-07 | PDF 1,006.8 KB |
| External Photos | External Photos | 2013-07-11 | PDF 731.3 KB |
| External Photos | External Photos | 2011-11-07 | PDF 1,006.6 KB |
| ID Label and Location | ID Label/Location Info | 2011-11-07 | PDF 72.7 KB |
| Test Setup Photos | Test Setup Photos | 2013-07-11 | PDF 342.7 KB |
| Test Setup Photos | Test Setup Photos | 2011-11-07 | PDF 1,006.9 KB |
| Test Report | Test Report | 2013-07-11 | PDF 2.1 MB |
| Test Report | Test Report | 2011-11-07 | PDF 2.9 MB |
| Authorization Letter | Cover Letter(s) | 2013-07-11 | PDF 379.5 KB |
| Class II Permissive Change Request Letter | Cover Letter(s) | 2013-07-11 | PDF 140.5 KB |
| Confidentiality Request | Cover Letter(s) | 2013-07-11 | PDF 21.2 KB |
| Authorization Letter | Cover Letter(s) | 2011-11-07 | PDF 30.4 KB |
| Confidentiality Request | Cover Letter(s) | 2011-11-07 | PDF 46 KB |
| MPE Prediction | RF Exposure Info | 2013-07-11 | PDF 62 KB |
| MPE Prediction | RF Exposure Info | 2011-11-07 | PDF 28.1 KB |
Application Information
| Application ID | EjJ12/GOiTyJKeY5HxoV4g== |
|---|---|
| Final Action Date | 2013-07-11 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0020276143 |
| Model | -DA1101 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | 802.11n In-Wall / Ceiling Wireless Access Point |
| Responsible Party | Fred Duffy, Design Engineer, fred.duffy@legrand.us |
| Technical Contact | Tse-Ming Chang, Worldwide Testing Services (Taiwan) Co., Ltd., john@wts-lab.com |
| Test Firm | Danny Sung, Worldwide Testing Services (Taiwan) Co., Ltd., danny@wts-lab.com |
| TCB Email | JoergKusig@eurofins.de |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is the maximum combined conducted power. The device is operating in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Class II Permissive Change as described in this filing. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| EjJ12/GOiTyJKeY5HxoV4g== | 2013-07-11 | Class II permissive change or modification of presently authorized equipment |
| JhAFIgpuHq5lm93k8UuydQ== | 2011-11-07 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application JhAFIgpuHq5lm93k8UuydQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 11/07/2011 Application Dated: 11/07/2011 |
| Pass & Seymour, Inc. d/b/a Legrand |
| 301 Fulling Mill Road |
| Suite G |
| Middletown, PA 17057 |
| Attention: Fred Duffy , Design Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YV8-DA1101 |
| Name of Grantee: | Pass & Seymour, Inc. d/b/a Legrand |
| Equipment Class: | Digital Transmission System |
| Notes: | 802.11n In-Wall / Ceiling Wireless Access Point |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 15C | 2412.0 - 2462.0 | 0.04603 | ||
| MO | 15C | 2422.0 - 2452.0 | 0.01644 |
| Power output listed is the maximum combined conducted power. The device is operating in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application JhAFIgpuHq5lm93k8UuydQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Pass & Seymour, Inc. d/b/a Legrand 301 Fulling Mill Road Suite G Middletown, PA 17057 United States |
Date of Grant: 11/07/2011 Application Dated: 11/07/2011 |
| Attention: Fred Duffy , Design Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YV8-DA1101 |
| Name of Grantee: | Pass & Seymour, Inc. d/b/a Legrand |
| Equipment Class: | Digital Transmission System |
| Notes: | 802.11n In-Wall / Ceiling Wireless Access Point |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 15C | 2412.0 - 2462.0 | 0.04603 | ||
| MO | 15C | 2422.0 - 2452.0 | 0.01644 |
| Power output listed is the maximum combined conducted power. The device is operating in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 07/11/2013 Application Dated: 07/11/2013 |
| Pass & Seymour, Inc. d/b/a Legrand |
| 301 Fulling Mill Road |
| Suite G |
| Middletown, PA 17057 |
| Attention: Fred Duffy , Design Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YV8-DA1101 |
| Name of Grantee: | Pass & Seymour, Inc. d/b/a Legrand |
| Equipment Class: | Digital Transmission System |
| Notes: | 802.11n In-Wall / Ceiling Wireless Access Point |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 15C | 2412.0 - 2462.0 | 0.028184 | ||
| MO | 15C | 2422.0 - 2452.0 | 0.014028 |
| Power output listed is the maximum combined conducted power. The device is operating in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Class II Permissive Change as described in this filing. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application EjJ12/GOiTyJKeY5HxoV4g==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Pass & Seymour, Inc. d/b/a Legrand 301 Fulling Mill Road Suite G Middletown, PA 17057 United States |
Date of Grant: 07/11/2013 Application Dated: 07/11/2013 |
| Attention: Fred Duffy , Design Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YV8-DA1101 |
| Name of Grantee: | Pass & Seymour, Inc. d/b/a Legrand |
| Equipment Class: | Digital Transmission System |
| Notes: | 802.11n In-Wall / Ceiling Wireless Access Point |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 15C | 2412.0 - 2462.0 | 0.028184 | ||
| MO | 15C | 2422.0 - 2452.0 | 0.014028 |
| Power output listed is the maximum combined conducted power. The device is operating in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Class II Permissive Change as described in this filing. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: |