FCC ID YVF-VS200
Wi-Fi Patient Monitoring Device
by Intelesens Limited
Grantee Code: YVF Product Code: VS200
Latest application date: 2015-11-13
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Class II permissive change or modification of presently authorized equipment | 2015-11-13 |
| 2412-2462 MHz | Class II permissive change or modification of presently authorized equipment | 2013-05-24 |
| 2412-2462 MHz | Original Equipment | 2011-04-04 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2016-03-31 | PDF 3 MB |
| User Manual Part 1 | Users Manual | 2013-09-14 | PDF 3.2 MB |
| User Manual Part 2 | Users Manual | 2013-09-14 | PDF 3.3 MB |
| User Manual Part 3 | Users Manual | 2013-09-14 | PDF 2.5 MB |
| User Manual | Users Manual | 2011-04-04 | PDF 1 MB |
| Internal Photos | Internal Photos | 2016-03-31 | PDF 642.6 KB |
| Internal Photos | Internal Photos | 2013-09-14 | PDF 1.6 MB |
| Internal Photos | Internal Photos | 2011-04-04 | PDF 145.4 KB |
| External Photos | External Photos | 2016-03-31 | PDF 429 KB |
| External Photos | External Photos | 2013-09-14 | PDF 3 MB |
| External Photos | External Photos | 2011-04-04 | PDF 154 KB |
| Label Detail | ID Label/Location Info | 2013-05-24 | PDF 1 MB |
| Label Detail | ID Label/Location Info | 2011-04-04 | PDF 59.4 KB |
| SAR Test Set Up | Test Setup Photos | 2016-03-31 | PDF 1.5 MB |
| Test Set Up | Test Setup Photos | 2013-09-14 | PDF 1.7 MB |
| Test Set Up | Test Setup Photos | 2011-04-04 | PDF 1,003.3 KB |
| SAR Report | RF Exposure Info | 2013-05-24 | PDF 1.9 MB |
| Test Report Emissions | Test Report | 2013-05-24 | PDF 700.2 KB |
| Test Report Power | Test Report | 2013-05-24 | PDF 514.7 KB |
| 15 B Test Report | Test Report | 2011-04-04 | PDF 530.9 KB |
| 15 C Test Report | Test Report | 2011-04-04 | PDF 2.2 MB |
| Confirmation of 15C Test Report Applicability | Cover Letter(s) | 2011-04-04 | PDF 40.1 KB |
| EIRP Test Report | Test Report | 2011-04-04 | PDF 160.8 KB |
| Authorisation Request | Cover Letter(s) | 2015-11-13 | PDF 170.1 KB |
| Confidentiality Request | Cover Letter(s) | 2015-11-13 | PDF 185.4 KB |
| Permissive Change Request | Cover Letter(s) | 2015-11-13 | PDF 112.6 KB |
| Agency Form | Cover Letter(s) | 2013-05-24 | PDF 128.1 KB |
| Confidenatiality Request | Cover Letter(s) | 2013-05-24 | PDF 148.8 KB |
| Permissive Change Request | Cover Letter(s) | 2013-05-24 | PDF 163.3 KB |
| Agency Form | Cover Letter(s) | 2011-04-04 | PDF 65.1 KB |
| Confidentiality Request | Cover Letter(s) | 2011-04-04 | PDF 86 KB |
| Manufacturers Authority to Use Module Exhbits | Cover Letter(s) | 2011-04-04 | PDF 78.2 KB |
| SAR Report Part 1 | RF Exposure Info | 2015-11-13 | PDF 934.9 KB |
| SAR Report Part 3 | RF Exposure Info | 2015-11-13 | PDF 2.6 MB |
| Tune Up Info. | Parts List/Tune Up Info | 2013-05-24 | PDF 108 KB |
| SAR Report V4 | RF Exposure Info | 2011-04-04 | PDF 2.3 MB |
| Tune Up Info | Parts List/Tune Up Info | 2011-04-04 | PDF 45.5 KB |
| Schematics Metadata only | Schematics | PDF 69.4 KB | |
| SAR LAb Correspondecne Info Metadata only | Operational Description | PDF 155.1 KB | |
| SAR Lab KDB Correspondence Metadata only | Operational Description | PDF 87.8 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 1.2 MB | |
| Tune Up Info Metadata only | Parts List/Tune Up Info | PDF 36.2 KB |
Application Information
| Application ID | mrLgBBbPfmgOvB2j8EWExA== |
|---|---|
| Final Action Date | 2015-11-13 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0020257853 |
| Model | VS200 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Wi-Fi Patient Monitoring Device |
| Responsible Party | Patricia Pepper, Mrs, patricia.pepper@intelesens.com |
| Technical Contact | Ian McCullough, Intelesens Ltd, ian.mccullough@intelesens.com |
| Non-Technical Contact | Patricia Pepper, Intelesens Ltd, patricia.pepper@intelesens.com |
| Test Firm | Darren Rust, UL VS Ltd, darren.rust@ul.com |
| TCB Email | certification@ul.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 03/31/2016 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | Yes |
| Grant Comments | Power output is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. The highest reported body SAR is 0.93W/kg. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. The device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Class II Permissive change for minor product changes to accommodate a different battery mounting position. The highest reported body SAR is 0.65W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| mrLgBBbPfmgOvB2j8EWExA== | 2015-11-13 | Class II permissive change or modification of presently authorized equipment |
| 0na8Dvr43Fejs6tScgwnww== | 2013-05-24 | Class II permissive change or modification of presently authorized equipment |
| +w6+hdePMs8usS1SUbrEwA== | 2011-04-04 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2412-2462 MHz | 0.0630000 | 15C |
Grants
TCB Grant - Application mrLgBBbPfmgOvB2j8EWExA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL International (UK) Ltd Unit 1 - 3 Horizon Kingsland Business Park Wade Road Basingstoke, RG24 8AH United Kingdom |
Date of Grant: 11/13/2015 Application Dated: 10/28/2015 |
| Intelesens Limited |
| 17 Heron Road |
| Belfast, BT3 9LE United Kingdom |
| Attention: Patricia Pepper , Mrs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YVF-VS200 |
| Name of Grantee: | Intelesens Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | Wi-Fi Patient Monitoring Device |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.063 |
| Power output is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. The highest reported body SAR is 0.93W/kg. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. The device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Class II Permissive change for minor product changes to accommodate a different battery mounting position. The highest reported body SAR is 0.65W/kg. |
EAS Grant - Application mrLgBBbPfmgOvB2j8EWExA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Intelesens Limited 17 Heron Road Belfast, BT3 9LE United Kingdom |
Date of Grant: 11/13/2015 Application Dated: 10/28/2015 |
| Attention: Patricia Pepper , Mrs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YVF-VS200 |
| Name of Grantee: | Intelesens Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | Wi-Fi Patient Monitoring Device |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.063 |
| Power output is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. The highest reported body SAR is 0.93W/kg. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. The device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Class II Permissive change for minor product changes to accommodate a different battery mounting position. The highest reported body SAR is 0.65W/kg. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL VS Ltd Unit 3 Horizon, Wade Road, Kingsland Business Park, Basingstoke, RG24 8AH United Kingdom |
Date of Grant: 05/24/2013 Application Dated: 05/02/2013 |
| Intelesens Limited |
| 17 Heron Road |
| Belfast, BT3 9LE United Kingdom |
| Attention: Patricia Pepper , Mrs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YVF-VS200 |
| Name of Grantee: | Intelesens Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | WI-FI Patient Monitoring Device |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.063 |
| Power output is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. The highest reported body SAR is 0.93W/Kg. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. The device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Class II Permissive change for new product enclosure and minor PCB changes. |
EAS Grant - Application 0na8Dvr43Fejs6tScgwnww==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Intelesens Limited 17 Heron Road Belfast, BT3 9LE United Kingdom |
Date of Grant: 05/24/2013 Application Dated: 05/02/2013 |
| Attention: Patricia Pepper , Mrs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YVF-VS200 |
| Name of Grantee: | Intelesens Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | WI-FI Patient Monitoring Device |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.063 |
| Power output is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. The highest reported body SAR is 0.93W/Kg. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. The device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Class II Permissive change for new product enclosure and minor PCB changes. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL VS Ltd Unit 3 Horizon, Wade Road, Kingsland Business Park, Basingstoke, RG24 8AH United Kingdom |
Date of Grant: 04/04/2011 Application Dated: 04/04/2011 |
| Intelesens Limited |
| 17 Heron Road |
| Belfast, BT3 9LE United Kingdom |
| Attention: Patricia Pepper , Mrs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YVF-VS200 |
| Name of Grantee: | Intelesens Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | WIFI Patient Monitoring Device |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.063 |
| Power output is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. The highest reported SAR value is 0.88W/Kg body. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. The device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures |
EAS Grant - Application +w6+hdePMs8usS1SUbrEwA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Intelesens Limited 17 Heron Road Belfast, BT3 9LE United Kingdom |
Date of Grant: 04/04/2011 Application Dated: 04/04/2011 |
| Attention: Patricia Pepper , Mrs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YVF-VS200 |
| Name of Grantee: | Intelesens Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | WIFI Patient Monitoring Device |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.063 |
| Power output is conducted. SAR compliance for body-worn operating conditions is limited to the specific configurations tested for this filing. The highest reported SAR value is 0.88W/Kg body. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. The device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures |
| Mail To: |