FCC ID YWZ-S3I0005

S3i Hard Tag

by Checkpoint Systems, Inc.

Grantee Code: YWZ   Product Code: S3I0005
Latest application date: 2014-07-02

FCC ID Device Details

FCC IDYWZ-S3I0005
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeYWZ
Product CodeS3I0005
Applicant BusinessCheckpoint Systems, Inc. 🇺🇸
Related Domains checkpt.com
Equipment ClassS3i Hard Tag
Test FirmAdvanced Compliance Solutions, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2405-2480 MHzOriginal Equipment2014-07-02

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2014-08-16PDF 725.4 KB
Internal PhotosInternal Photos2014-08-16PDF 135.5 KB
External PhotosExternal Photos2014-07-02PDF 208.5 KB
Label InformationID Label/Location Info2014-07-02PDF 524.8 KB
Test Setup PhotosTest Setup Photos2014-07-02PDF 334.8 KB
Test ReportTest Report2014-07-02PDF 1.9 MB
Agency AgreementCover Letter(s)2014-07-02PDF 36.5 KB
Confidentiality RequestCover Letter(s)2014-07-02PDF 49.5 KB
FCC Cover LetterCover Letter(s)2014-07-02PDF 11.9 KB
RF ExposureRF Exposure Info2014-07-02PDF 46.5 KB
Block Diagram Metadata onlyBlock DiagramPDF 123.1 KB
Schematics Metadata onlySchematicsPDF 472.9 KB
Theory of Operation Metadata onlyOperational DescriptionPDF 436 KB

Application Information

Application IDk9zaoOppe7Ud59Ekr28QPQ==
Final Action Date2014-07-02
Application PurposeOriginal Equipment
Applicant FRN0020294666
ModelS3I0005
Frequency Range2405-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionS3i Hard Tag
Responsible PartyPeter Bremer, VP R&D; Worldwide, Peter.Bremer@checkpt.com , 856-628-2491
AgentSam Sam Sam, Advanced Compliance Solutions, Inc.
Test FirmRandy Abernathy, Advanced Compliance Solutions, Inc., rabernathy@acstestlab.com , 770-831-8048
TCB Emailjwoods@acstestlab.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date08/16/2014
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment may operate in direct contact with the body of the user under normal operating conditions. Device must operate with a source-based, time-averaged duty cycle not to exceed 15.4% controlled via firmware or software.

Applications

Application IDDatePurpose
k9zaoOppe7Ud59Ekr28QPQ==2014-07-02Original Equipment

Equipment Authorization

FrequencyOutputRules
2405-2480 MHz0.002400015C

Grants

TCB Grant - Application k9zaoOppe7Ud59Ekr28QPQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  TUV SUD America Inc.
401 Edgewater Place Suite #500
Wakefield, MA 01880
Date of Grant: 07/02/2014

Application Dated: 07/02/2014
Checkpoint Systems, Inc.
101 Wolf Drive
Thorofare, NJ 08086
 
Attention: Peter Bremer , VP R&D Worldwide

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YWZ-S3I0005
Name of Grantee:  Checkpoint Systems, Inc.
Equipment Class: Digital Transmission System
Notes: S3i Hard Tag
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2480.0 0.0024  

Power listed is conducted. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment may operate in direct contact with the body of the user under normal operating conditions. Device must operate with a source-based, time-averaged duty cycle not to exceed 15.4% controlled via firmware or software.

EAS Grant - Application k9zaoOppe7Ud59Ekr28QPQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Checkpoint Systems, Inc.
101 Wolf Drive
Thorofare, NJ 08086
United States
  Date of Grant: 07/02/2014

Application Dated: 07/02/2014
 
Attention: Peter Bremer , VP R&D Worldwide

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  YWZ-S3I0005
Name of Grantee:  Checkpoint Systems, Inc.
Equipment Class: Digital Transmission System
Notes: S3i Hard Tag
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2405.0  -  2480.0 0.0024  

Power listed is conducted. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment may operate in direct contact with the body of the user under normal operating conditions. Device must operate with a source-based, time-averaged duty cycle not to exceed 15.4% controlled via firmware or software.



Mail To: