FCC ID YZZGRP2602WV2
IP Phone
by Grandstream Networks, Inc.
Grantee Code: YZZ Product Code: GRP2602WV2
Latest application date: 2024-06-29
FCC ID Device Details
| FCC ID | YZZGRP2602WV2 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | YZZ |
| Product Code | GRP2602WV2 |
| Applicant Business | Grandstream Networks, Inc. 🇺🇸 |
| Related Domains | |
| Equipment Class | IP Phone |
| Test Firm | Shenzhen UnionTrust Quality and Technology Co., Lt |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2024-06-29 |
| 5745-5825 MHz | Original Equipment | 2024-06-29 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2024-12-25 | PDF 1 MB |
| Internal photos | Internal Photos | 2024-12-25 | PDF 2.5 MB |
| External photos | External Photos | 2024-12-25 | PDF 3.3 MB |
| ID label and location | ID Label/Location Info | 2024-06-29 | PDF 57.5 KB |
| label 2602 | ID Label/Location Info | 2024-06-29 | PDF 352.2 KB |
| Test Setup photo | Test Setup Photos | 2024-12-25 | PDF 1 MB |
| Test Setup photo | Test Setup Photos | 2024-12-25 | PDF 844.2 KB |
| Test Setup photo | Test Setup Photos | 2024-12-25 | PDF 1 MB |
| Antenna Specification | Test Report | 2024-06-29 | PDF 458 KB |
| Test report | Test Report | 2024-06-29 | PDF 2.7 MB |
| Test report 1 | Test Report | 2024-06-29 | PDF 4.8 MB |
| Test report 1 | Test Report | 2024-06-29 | PDF 5 MB |
| Test report 2 | Test Report | 2024-06-29 | PDF 4.6 MB |
| Test report 2 | Test Report | 2024-06-29 | PDF 4.2 MB |
| Test report 3 | Test Report | 2024-06-29 | PDF 4.8 MB |
| Test report 4 | Test Report | 2024-06-29 | PDF 5 MB |
| Test report 5 | Test Report | 2024-06-29 | PDF 5 MB |
| Test report 6 | Test Report | 2024-06-29 | PDF 4.7 MB |
| Test report 7 | Test Report | 2024-06-29 | PDF 1.9 MB |
| Attestation_Statement | Attestation Statements | 2024-06-29 | PDF 422.9 KB |
| US_Agent | Attestation Statements | 2024-06-29 | PDF 179 KB |
| Confidentiality | Cover Letter(s) | 2024-06-29 | PDF 414.6 KB |
| Letter Authorization | Cover Letter(s) | 2024-06-29 | PDF 153.6 KB |
| Software Configuration | Cover Letter(s) | 2024-06-29 | PDF 150.7 KB |
| MPE | RF Exposure Info | 2024-06-29 | PDF 895.3 KB |
| Block Diagram Metadata only | Block Diagram | PDF 78.9 KB | |
| Schematics Metadata only | Schematics | PDF 293.7 KB | |
| Schematics 44B1 Metadata only | Schematics | PDF 562.9 KB | |
| Operational Description Metadata only | Operational Description | PDF 57.6 KB | |
| Software Security Metadata only | SDR Software/Security Info. | PDF 320.4 KB |
Application Information
| Application ID | xaPE8apX1Kd1fa4AZFBX6w== |
|---|---|
| Final Action Date | 2024-06-29 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0020352431 |
| Model | GRP2602WV2 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | IP Phone |
| Responsible Party | Ning Wei, Nwei@grandstream.com |
| Technical Contact | Billy li, Shenzhen UnionTrust Quality and Technology Co., Lt, billy.li@uttlab.com |
| Non-Technical Contact | Billy li, Shenzhen UnionTrust Quality and Technology Co., Lt, billy.li@uttlab.com |
| Test Firm | George Luo, Shenzhen UnionTrust Quality and Technology Co., Lt, quality@uttlab.com |
| TCB Email | elabscert@applus.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 12/25/2024 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted.The antenna(s) used with thistransmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.The device contains 20MHz and 40MHz bandwidth. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| xaPE8apX1Kd1fa4AZFBX6w== | 2024-06-29 | Original Equipment |
| n7FxSn1mp1BHPl4IfAGjCA== | 2024-06-29 | Original Equipment |
| 3fY/sQx6XhyWaHbvJxdkQQ== | 2024-06-29 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application xaPE8apX1Kd1fa4AZFBX6w==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
LGAI Technological Center S.A. (APPLUS) Ronda de la Font del Carme, s/n <BR>P.O. Box 08193, Barcelona, Spain |
Date of Grant: 06/29/2024 Application Dated: 06/28/2024 |
| Grandstream Networks, Inc. |
| 126 Brookline Ave, 3rd Floor |
| Boston, MA 02215 USA |
| Attention: Ning Wei |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YZZGRP2602WV2 |
| Name of Grantee: | Grandstream Networks, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | IP Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 68 CC | 15C | 2412.0 - 2462.0 | 0.52 |
| Output power listed is conducted.The antenna(s) used with thistransmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.The device contains 20MHz and 40MHz bandwidth. |
| 68: | This grant does not pertain to equipment approval requirements under Part 68. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application xaPE8apX1Kd1fa4AZFBX6w==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Grandstream Networks, Inc. 126 Brookline Ave, 3rd Floor Boston, MA 02215 USA United States |
Date of Grant: 06/29/2024 Application Dated: 06/28/2024 |
| Attention: Ning Wei |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YZZGRP2602WV2 |
| Name of Grantee: | Grandstream Networks, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | IP Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 68 CC | 15C | 2412.0 - 2462.0 | 0.52 |
| Output power listed is conducted.The antenna(s) used with thistransmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.The device contains 20MHz and 40MHz bandwidth. |
| 68: | This grant does not pertain to equipment approval requirements under Part 68. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
LGAI Technological Center S.A. (APPLUS) Ronda de la Font del Carme, s/n <BR>P.O. Box 08193, Barcelona, Spain |
Date of Grant: 06/29/2024 Application Dated: 06/28/2024 |
| Grandstream Networks, Inc. |
| 126 Brookline Ave, 3rd Floor |
| Boston, MA 02215 USA |
| Attention: Ning Wei |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YZZGRP2602WV2 |
| Name of Grantee: | Grandstream Networks, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | IP Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 68 CC | 15E | 5180.0 - 5240.0 | 0.0305 | ||
| 68 CC ND | 15E | 5260.0 - 5320.0 | 0.0305 | ||
| 68 CC ND | 15E | 5500.0 - 5720.0 | 0.0369 | ||
| 68 CC | 15E | 5745.0 - 5825.0 | 0.0354 |
| Output power listed is conducted. This device complies with the Dynamic Frequency Selection (DFS) requirements of KDB 905462 D03 as a Client only without Radar Detection.The antenna(s) used with thistransmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. The device contains 20MHz and 40MHz. |
| 68: | This grant does not pertain to equipment approval requirements under Part 68. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application n7FxSn1mp1BHPl4IfAGjCA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Grandstream Networks, Inc. 126 Brookline Ave, 3rd Floor Boston, MA 02215 USA United States |
Date of Grant: 06/29/2024 Application Dated: 06/28/2024 |
| Attention: Ning Wei |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YZZGRP2602WV2 |
| Name of Grantee: | Grandstream Networks, Inc. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | IP Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 68 CC | 15E | 5180.0 - 5240.0 | 0.0305 | ||
| 68 CC ND | 15E | 5260.0 - 5320.0 | 0.0305 | ||
| 68 CC ND | 15E | 5500.0 - 5720.0 | 0.0369 | ||
| 68 CC | 15E | 5745.0 - 5825.0 | 0.0354 |
| Output power listed is conducted. This device complies with the Dynamic Frequency Selection (DFS) requirements of KDB 905462 D03 as a Client only without Radar Detection.The antenna(s) used with thistransmitter must be installed to provide a minimum separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. The device contains 20MHz and 40MHz. |
| 68: | This grant does not pertain to equipment approval requirements under Part 68. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
LGAI Technological Center S.A. (APPLUS) Ronda de la Font del Carme, s/n <BR>P.O. Box 08193, Barcelona, Spain |
Date of Grant: 06/29/2024 Application Dated: 06/28/2024 |
| Grandstream Networks, Inc. |
| 126 Brookline Ave, 3rd Floor |
| Boston, MA 02215 USA |
| Attention: Ning Wei |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YZZGRP2602WV2 |
| Name of Grantee: | Grandstream Networks, Inc. |
| Equipment Class: | Part 15 Class B Digital Device |
| Notes: | IP Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 68 CC | 15B | - |
| 68: | This grant does not pertain to equipment approval requirements under Part 68. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application 3fY/sQx6XhyWaHbvJxdkQQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Grandstream Networks, Inc. 126 Brookline Ave, 3rd Floor Boston, MA 02215 USA United States |
Date of Grant: 06/29/2024 Application Dated: 06/28/2024 |
| Attention: Ning Wei |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | YZZGRP2602WV2 |
| Name of Grantee: | Grandstream Networks, Inc. |
| Equipment Class: | Part 15 Class B Digital Device |
| Notes: | IP Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 68 CC | 15B | - |
| 68: | This grant does not pertain to equipment approval requirements under Part 68. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |