FCC ID Z36-701
Wireless Thermometer
by Raiing Medical Company
Grantee Code: Z36 Product Code: 701
Latest application date: 2013-05-21
FCC ID Device Details
| FCC ID | Z36-701 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | Z36 |
| Product Code | 701 |
| Applicant Business | Raiing Medical Company 🇨🇳 |
| Related Domains | |
| Equipment Class | Wireless Thermometer |
| Test Firm | Shenzhen Huatongwei International Insp. Co., Ltd |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2013-05-21 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| user manual | Users Manual | 2013-05-21 | PDF 538 KB |
| internal photos | Internal Photos | 2013-05-21 | PDF 171.1 KB |
| external photos | External Photos | 2013-05-21 | PDF 107.1 KB |
| label | ID Label/Location Info | 2013-05-21 | PDF 225.7 KB |
| test setup photos | Test Setup Photos | 2013-05-21 | PDF 151.9 KB |
| test report | Test Report | 2013-05-21 | PDF 842.8 KB |
| authorization letter | Cover Letter(s) | 2013-05-21 | PDF 144.2 KB |
| confidentially letter | Cover Letter(s) | 2013-05-21 | PDF 174.3 KB |
Application Information
| Application ID | sNGszH3bPgzp/ut1+kxvXw== |
|---|---|
| Final Action Date | 2013-05-21 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0022696892 |
| Model | -701 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Wireless Thermometer |
| Responsible Party | Wei Wu, Cheif Engineer, vii@raiing.com |
| Test Firm | Moffy Yu, Shenzhen Huatongwei International Insp. Co., Ltd, moffy.yu@szhtw.com.cn |
| TCB Email | K.Knoerig@emcc.de |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is peak conducted. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC accepted multi-transmitter procedures. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| sNGszH3bPgzp/ut1+kxvXw== | 2013-05-21 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2402-2480 MHz | 0.0005140 | 15C |
Grants
TCB Grant - Application sNGszH3bPgzp/ut1+kxvXw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
EMCCert Dr. Rasek GmbH Stoernhofer Berg 15 91364 Unterleinleiter, Germany |
Date of Grant: 05/21/2013 Application Dated: 05/21/2013 |
| Raiing Medical Company |
| 21 Huoju St, |
| Beijing, China |
| Attention: Wei Wu , Cheif Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Z36-701 |
| Name of Grantee: | Raiing Medical Company |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless Thermometer |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.000514 |
| Power output listed is peak conducted. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC accepted multi-transmitter procedures. |
EAS Grant - Application sNGszH3bPgzp/ut1+kxvXw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Raiing Medical Company 21 Huoju St, Beijing, China |
Date of Grant: 05/21/2013 Application Dated: 05/21/2013 |
| Attention: Wei Wu , Cheif Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | Z36-701 |
| Name of Grantee: | Raiing Medical Company |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless Thermometer |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.000514 |
| Power output listed is peak conducted. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC accepted multi-transmitter procedures. |
| Mail To: |