FCC ID Z8H89FT0069

ePMP 6GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point

by Cambium Networks Inc.

Grantee Code: Z8H   Product Code: 89FT0069
Latest application date: 2025-08-19

FCC ID Device Details

FCC IDZ8H89FT0069
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeZ8H
Product Code89FT0069
Applicant BusinessCambium Networks Inc. 🇺🇸
Related Domains cambiumnetworks.com
Equipment ClassePMP 6GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point
Test FirmSporton International Inc. Hsinchu Laboratory

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
6535-6855 MHzClass III permissive change to software defined radio2025-08-19
5955-6415 MHzClass III permissive change to software defined radio2024-08-28
5955-6415 MHzClass III permissive change to software defined radio2024-08-27
5745-5825 MHzClass III permissive change to software defined radio2024-04-30
5955-6415 MHzClass III permissive change to software defined radio2024-04-29
5955-6415 MHzClass III permissive change to software defined radio2024-04-26
6535-6855 MHzClass III permissive change to software defined radio2024-04-25
5745-5825 MHzOriginal Equipment2022-11-21

Exhibits

DocumentTypeAvailableFile
OpDes Geolocation General Desc. Metadata onlyUsers Manual2024-10-27PDF 172.3 KB
User Manual pt. 1Users Manual2024-10-27PDF 5.2 MB
User Manual pt. 2Users Manual2024-10-27PDF 3.2 MB
Geolocation General DescriptionUsers Manual2024-10-22PDF 172.3 KB
Geolocation Justification Report Metadata onlyUsers Manual2024-10-22PDF 897 KB
User Manual Part 1Users Manual2024-10-22PDF 5.2 MB
User Manual Part 2Users Manual2024-10-22PDF 3.2 MB
User ManualUsers Manual2023-05-20PDF 4.8 MB
Internal PhotosInternal Photos2024-10-27PDF 3.9 MB
Internal PhotosInternal Photos2023-05-20PDF 2.3 MB
External PhotosExternal Photos2024-10-27PDF 3.7 MB
External PhotosExternal Photos2023-05-20PDF 1.5 MB
Label Info and LocationID Label/Location Info2024-04-30PDF 75.1 KB
Label and LocationID Label/Location Info2024-04-25PDF 75.1 KB
Label LocationID Label/Location Info2022-11-21PDF 75 KB
TSUP 5G UNII 3 Metadata onlyTest Setup Photos2024-10-27PDF 593.3 KB
TSUP 6G UNII 5+7 Metadata onlyTest Setup Photos2024-10-27PDF 703.5 KB
Test Setup Photos 5G UNII Metadata onlyTest Setup Photos2024-10-27PDF 589.2 KB
Test Setup Photos 5G UNII 3Test Setup Photos2024-10-27PDF 589.2 KB
TSUP 6G UNII 5+7Test Setup Photos2024-10-26PDF 698.6 KB
TSUP 6G Metadata onlyTest Setup Photos2024-10-22PDF 703.5 KB
TSUPTest Setup Photos2024-08-28PDF 547.4 KB
Test Setup PhotosTest Setup Photos2023-05-20PDF 362.7 KB
Dish Antenna ReportTest Report2025-08-19PDF 180.9 KB
Sector Antenna ReportTest Report2025-08-19PDF 331.6 KB
Test Report UNII5&7Test Report2025-08-19PDF 854.8 KB
Antenna Report DishTest Report2024-08-28PDF 180.9 KB
Antenna Report SectorTest Report2024-08-28PDF 331.6 KB
Test ReportTest Report2024-08-28PDF 1.2 MB
AFC DUT Test Harness ReportTest Report2024-04-30PDF 2.7 MB
Test Report 5G UNII Metadata onlyTest Report2024-04-30PDF 2 MB
Test Report 5G UNII 3Test Report2024-04-30PDF 2 MB
Antenna 6G DishTest Report2024-04-29PDF 302.7 KB
Antenna 6G Dish AntennaTest Report2024-04-29PDF 180.9 KB
Antenna 6G SectorTest Report2024-04-29PDF 331.6 KB
Test Report 6G UNII 5+7 Part 1Test Report2024-04-29PDF 4.1 MB
Test Report 6G UNII 5+7 Part 1Test Report2024-04-29PDF 4.5 MB
Test Report 6G UNII 5+7 Part 2Test Report2024-04-29PDF 3 MB
Test Report 6G UNII 5+7 Part 2Test Report2024-04-29PDF 2.4 MB
Test Report 6G UNII 5+7 pt. 1Test Report2024-04-29PDF 3.2 MB
Test Report 6G UNII 5+7 pt. 2Test Report2024-04-29PDF 3.6 MB
AFC DUT Test Harness ReportTest Report2024-04-26PDF 2.9 MB
TR AFC DUT Test HarnessTest Report2024-04-25PDF 2.7 MB
Test Report 6G UNII 5,7 Pt 1Test Report2024-04-25PDF 3.2 MB
Test Report 6G UNII 5,7 Pt 2Test Report2024-04-25PDF 3.6 MB
AntennaTest Report2022-11-21PDF 403.8 KB
Test ReportTest Report2022-11-21PDF 1.7 MB
Att Statements 2.911(d)(5)(7)Attestation Statements2025-08-19PDF 117.1 KB
Att Statements 2.911(d)(5)(i)&(ii)Attestation Statements2025-08-19PDF 120.7 KB
Attestation Statement 2.911(d)(7)Attestation Statements2024-08-28PDF 240.6 KB
Attstn Stmt parts 2.911(d)(5)(i)&(ii)Attestation Statements2024-08-28PDF 232.2 KB
Attestation Statement Part 2.911(d)(7)Attestation Statements2024-04-30PDF 145.6 KB
Attstn Stmts Part 2.911(d)(5)(i)&(ii)Attestation Statements2024-04-30PDF 224.5 KB
Letter of Declaration 6E Standard ClientAttestation Statements2024-04-29PDF 114.9 KB
Declaration of 6E Fixed Client 6FCAttestation Statements2024-04-26PDF 115.3 KB
Attestation Statements Part 2.911(d)(7)Attestation Statements2024-04-25PDF 145.6 KB
Attstn Stmt part 2.911(d)(5)(i)&(ii)Attestation Statements2024-04-25PDF 224.5 KB
Dec Letter 6E Standard APAttestation Statements2024-04-25PDF 310.3 KB
C3PC LetterCover Letter(s)2025-08-19PDF 91.7 KB
POA LetterCover Letter(s)2025-08-19PDF 90.8 KB
C3PC LetterCover Letter(s)2024-08-28PDF 390.8 KB
Confidentiality LetterCover Letter(s)2024-08-28PDF 236.3 KB
POA LetterCover Letter(s)2024-08-28PDF 193 KB
C3PC LetterCover Letter(s)2024-04-30PDF 90.2 KB
Confidentiality LetterCover Letter(s)2024-04-30PDF 115.1 KB
POA LetterCover Letter(s)2024-04-30PDF 190.5 KB
Professional Installation DeclarationCover Letter(s)2024-04-30PDF 196.5 KB
Declaration of 6E Fixed Client 6FC Metadata onlyCover Letter(s)2024-04-26PDF 115.3 KB
Dec Letter 6E Standard AP Metadata onlyCover Letter(s)2024-04-25PDF 310.3 KB
Professional Installation LetterCover Letter(s)2024-04-25PDF 196.5 KB
Confidentiality RequestCover Letter(s)2022-11-21PDF 118.4 KB
P2P Declaration LetterCover Letter(s)2022-11-21PDF 45 KB
POA LetterCover Letter(s)2022-11-21PDF 89.9 KB
Pro Installation DeclarationCover Letter(s)2022-11-21PDF 114.5 KB
RF Exposure MPERF Exposure Info2025-08-19PDF 317.5 KB
RF Exposure MPERF Exposure Info2024-08-28PDF 397.5 KB
MPE ReportRF Exposure Info2024-04-30PDF 453.3 KB
MPE ReportRF Exposure Info2024-04-30PDF 446.7 KB
RF Exposure MPERF Exposure Info2024-04-30PDF 414.4 KB
MPE ReportRF Exposure Info2022-11-21PDF 346.9 KB
Block Diagram Metadata onlyBlock DiagramPDF 169.4 KB
Block Diagram Metadata onlyBlock DiagramPDF 169.6 KB
Schematics Metadata onlySDR Software/Security Info.PDF 3.3 MB
Schematics Metadata onlySchematicsPDF 3.3 MB
Schematics Metadata onlySchematicsPDF 3.3 MB
Checklist of PAG Review for SDR Metadata onlyOperational DescriptionPDF 146.6 KB
Op Des PIA Inquiry Submission Metadata onlyOperational DescriptionPDF 213.7 KB
Op Desc PIA Acceptance Metadata onlyOperational DescriptionPDF 216.7 KB
Op Desc PIA Inquiry Submission Metadata onlyOperational DescriptionPDF 213.7 KB
OpDes Geolocation Justificaiton Rpt Metadata onlyOperational DescriptionPDF 897 KB
OpDes PIA Inquiry Acceptance Letter Metadata onlyOperational DescriptionPDF 216.7 KB
Operational Description Metadata onlyOperational DescriptionPDF 217.3 KB
Operational Description Metadata onlyOperational DescriptionPDF 142.2 KB
Operational Description SDR & UNII Metadata onlySDR Software/Security Info.PDF 121.9 KB
Op Desc SDR and NII Metadata onlySDR Software/Security Info.PDF 121.9 KB
Op Description SDR Metadata onlySDR Software/Security InfPDF 134.8 KB
OpDes SDR and UNII Metadata onlySDR Software/Security Info.PDF 113.6 KB

Application Information

Application IDs0BIr4Ggd43fw7xbdjudDA==
Final Action Date2025-08-19
Application PurposeClass III permissive change to software defined radio
Applicant FRN0016216152
Model89FT0069
Frequency Range6535-6855 MHz
Equipment Class6FX - 15E 6 GHz Standard Client Device
Device DescriptionePMP 6GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point
Responsible PartySteven M. Payne, R.F. Principle Staff Engineer, steve.payne@cambiumnetworks.com , 224-392-5930
Test FirmAlex Chen, Sporton International Inc. Hsinchu Laboratory, alex@sporton.com.tw , 886-3-327-3456
TCB Emailtei@timcoengr.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioYes
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsPower listed is EIRP. Device operates with specific antennas as described in this filing. Professional installation is required. The antennas used for this device must be installed to provide a separation distance of at least 371 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80 and 160 MHz bandwidth modes. Class III Permissive Change: Add Contention Based Protocol capabilities via software update.

Applications

Application IDDatePurpose
s0BIr4Ggd43fw7xbdjudDA==2025-08-19Class III permissive change to software defined radio
BgWgTh/LL8M8Lh4mktEDEg==2024-08-28Class III permissive change to software defined radio
RMXfd74xrIh3aucJcJVSOg==2024-08-27Class III permissive change to software defined radio
sQxoukrWjRN3ajoaZvlQPA==2024-04-30Class III permissive change to software defined radio
Hx1eUoyfP+xwAFO3/OB5ww==2024-04-29Class III permissive change to software defined radio
XfrTvFC1DA+OpAZAsnDi7g==2024-04-26Class III permissive change to software defined radio
YQ6lZKLsocxCSlSMNGd4AQ==2024-04-25Class III permissive change to software defined radio
sWVu0w37p3SF/Mh8w+QJ3w==2022-11-21Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
5745-5825 MHz0.579000015EMO
5745-5825 MHz0.773000015EMO
5955-6415 MHz3.63115EEP, MO
5955-6415 MHz3.92615EEP, MO
5955-6415 MHz0.989EP, MO
6535-6855 MHz2.42115EEP, MO
6535-6855 MHz3.90815EEP, MO
6535-6855 MHz0.968EP, MO

Grants

TCB Grant - Application YQ6lZKLsocxCSlSMNGd4AQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 04/25/2024

Application Dated: 04/09/2024
Cambium Networks Inc.
3800 Golf Road
Suite 360
Rolling Meadows, IL 60008
 
Attention: Steven Payne , R.F. Principle Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Z8H89FT0069
Name of Grantee:  Cambium Networks Inc.
Equipment Class: 15E 6 GHz Standard Power Access Point
Notes: ePMP 6 GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EP MO 15E 5955.0  -  6415.0 3.631  
EP MO 15E 6535.0  -  6855.0 2.421  

Power listed is EIRP. Device operates with specific antennas as described in this filing. Professional installation is required. The antennas used for this device must be installed to provide a separation distance of at least 371 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80 and 160 MHz bandwidth modes.

Class III Permissive Change:

1. Adds 6 GHz Standard Power Access Point (6SD), Fixed Client (6FC) and Standard Client (6FX) operational modes via software update.

2. Add a new directional Sector Antenna for 5 GHz and 6 GHz which is of the same antenna type but lower gain than that of the original application.


EP: Output power is Effective Isotropic Radiated Power (EIRP)
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application YQ6lZKLsocxCSlSMNGd4AQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Cambium Networks Inc.
3800 Golf Road Suite 360
Rolling Meadows, IL 60008
United States
  Date of Grant: 04/25/2024

Application Dated: 04/09/2024
 
Attention: Steven Payne , R.F. Principle Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Z8H89FT0069
Name of Grantee:  Cambium Networks Inc.
Equipment Class: 15E 6 GHz Standard Power Access Point
Notes: ePMP 6 GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EP MO 15E 5955.0  -  6415.0 3.631  
EP MO 15E 6535.0  -  6855.0 2.421  

Power listed is EIRP. Device operates with specific antennas as described in this filing. Professional installation is required. The antennas used for this device must be installed to provide a separation distance of at least 371 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80 and 160 MHz bandwidth modes.

Class III Permissive Change:

1. Adds 6 GHz Standard Power Access Point (6SD), Fixed Client (6FC) and Standard Client (6FX) operational modes via software update.

2. Add a new directional Sector Antenna for 5 GHz and 6 GHz which is of the same antenna type but lower gain than that of the original application.


EP: Output power is Effective Isotropic Radiated Power (EIRP)
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application XfrTvFC1DA+OpAZAsnDi7g==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 04/26/2024

Application Dated: 04/25/2024
Cambium Networks Inc.
3800 Golf Road
Suite 360
Rolling Meadows, IL 60008
 
Attention: Steven Payne , R.F. Principle Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Z8H89FT0069
Name of Grantee:  Cambium Networks Inc.
Equipment Class: 15E 6 GHz Fixed Client
Notes: ePMP 6 GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EP MO 15E 5955.0  -  6415.0 3.631  
EP MO 15E 6535.0  -  6855.0 2.421  

Power listed is EIRP. Device operates with specific antennas as described in this filing. Professional installation is required. The antennas used for this device must be installed to provide a separation distance of at least 371 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80 and 160 MHz bandwidth modes.

Class III Permissive Change:

1. Adds 6 GHz Standard Power Access Point (6SD), Fixed Client (6FC) and Standard Client (6FX) operational modes via software update.

2. Add a new directional Sector Antenna for 5 GHz and 6 GHz which is of the same antenna type but lower gain than that of the original application.


EP: Output power is Effective Isotropic Radiated Power (EIRP)
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application XfrTvFC1DA+OpAZAsnDi7g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Cambium Networks Inc.
3800 Golf Road Suite 360
Rolling Meadows, IL 60008
United States
  Date of Grant: 04/26/2024

Application Dated: 04/25/2024
 
Attention: Steven Payne , R.F. Principle Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Z8H89FT0069
Name of Grantee:  Cambium Networks Inc.
Equipment Class: 15E 6 GHz Fixed Client
Notes: ePMP 6 GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EP MO 15E 5955.0  -  6415.0 3.631  
EP MO 15E 6535.0  -  6855.0 2.421  

Power listed is EIRP. Device operates with specific antennas as described in this filing. Professional installation is required. The antennas used for this device must be installed to provide a separation distance of at least 371 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80 and 160 MHz bandwidth modes.

Class III Permissive Change:

1. Adds 6 GHz Standard Power Access Point (6SD), Fixed Client (6FC) and Standard Client (6FX) operational modes via software update.

2. Add a new directional Sector Antenna for 5 GHz and 6 GHz which is of the same antenna type but lower gain than that of the original application.


EP: Output power is Effective Isotropic Radiated Power (EIRP)
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application sWVu0w37p3SF/Mh8w+QJ3w==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 11/21/2022

Application Dated: 11/09/2022
Cambium Networks Inc.
3800 Golf Road
Suite 360
Rolling Meadows, IL 60008
 
Attention: Steven Payne , R.F. Principle Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Z8H89FT0069
Name of Grantee:  Cambium Networks Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: ePMP 6 GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15E 5745.0  -  5825.0 0.579  

Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 371 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. This device supports 20, 40 and 80 MHz modes. Device requires professional installation

MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application sWVu0w37p3SF/Mh8w+QJ3w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Cambium Networks Inc.
3800 Golf Road Suite 360
Rolling Meadows, IL 60008
United States
  Date of Grant: 11/21/2022

Application Dated: 11/09/2022
 
Attention: Steven Payne , R.F. Principle Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Z8H89FT0069
Name of Grantee:  Cambium Networks Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: ePMP 6 GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15E 5745.0  -  5825.0 0.579  

Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 371 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. This device supports 20, 40 and 80 MHz modes. Device requires professional installation


MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application sQxoukrWjRN3ajoaZvlQPA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 04/30/2024

Application Dated: 04/29/2024
Cambium Networks Inc.
3800 Golf Road
Suite 360
Rolling Meadows, IL 60008
 
Attention: Steven Payne , R.F. Principle Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Z8H89FT0069
Name of Grantee:  Cambium Networks Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: ePMP 6 GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15E 5745.0  -  5825.0 0.773  

Output Power listed is the maximum conducted output power. Professional installation is required. The antenna(s) used for this transmitter must be installed and operated so as to provide a separation distance of at least 371 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance. This device supports 20, 40 and 80 MHz bandwidth modes.

Class III Permissive Change:

1. Adds 6 GHz Standard Power Access Point (6SD), Fixed Client (6FC) and Standard Client (6FX) operational modes via software update.

2. Add a new directional Sector Antenna for 5 GHz and 6 GHz which is of the same antenna type but lower gain than that of the original application.


MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application sQxoukrWjRN3ajoaZvlQPA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Cambium Networks Inc.
3800 Golf Road Suite 360
Rolling Meadows, IL 60008
United States
  Date of Grant: 04/30/2024

Application Dated: 04/29/2024
 
Attention: Steven Payne , R.F. Principle Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Z8H89FT0069
Name of Grantee:  Cambium Networks Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: ePMP 6 GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15E 5745.0  -  5825.0 0.773  

Output Power listed is the maximum conducted output power. Professional installation is required. The antenna(s) used for this transmitter must be installed and operated so as to provide a separation distance of at least 371 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance. This device supports 20, 40 and 80 MHz bandwidth modes.

Class III Permissive Change:

1. Adds 6 GHz Standard Power Access Point (6SD), Fixed Client (6FC) and Standard Client (6FX) operational modes via software update.

2. Add a new directional Sector Antenna for 5 GHz and 6 GHz which is of the same antenna type but lower gain than that of the original application.


MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application s0BIr4Ggd43fw7xbdjudDA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  IIA Lab Services, LLC
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 08/19/2025

Application Dated: 07/22/2025
Cambium Networks Inc.
3800 Golf Road
Suite 360
Rolling Meadows, IL 60008
 
Attention: Steven Payne , R.F. Principle Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Z8H89FT0069
Name of Grantee:  Cambium Networks Inc.
Equipment Class: 15E 6 GHz Standard Client Device
Notes: ePMP 6GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EP MO 15E 5955.0  -  6415.0 0.989  
EP MO 15E 6535.0  -  6855.0 0.968  

Power listed is EIRP. Device operates with specific antennas as described in this filing. Professional installation is required. The antennas used for this device must be installed to provide a separation distance of at least 371 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80 and 160 MHz bandwidth modes.

Class III Permissive Change: Add Contention Based Protocol capabilities via software update.


EP: Output power is Effective Isotropic Radiated Power (EIRP)
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application RMXfd74xrIh3aucJcJVSOg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 08/27/2024

Application Dated: 08/08/2024
Cambium Networks Inc.
3800 Golf Road
Suite 360
Rolling Meadows, IL 60008
 
Attention: Steven Payne , R.F. Principle Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Z8H89FT0069
Name of Grantee:  Cambium Networks Inc.
Equipment Class: 15E 6 GHz Standard Power Access Point
Notes: ePMP 6 GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EP MO 15E 5955.0  -  6415.0 3.926  
EP MO 15E 6535.0  -  6855.0 3.908  

Power listed is EIRP. Software Defined Radio. Professional installation is required. Device operates with specific antennas in MIMO configurations as described in this filing. The antennas used for this device must be installed to provide a separation distance of at least 371 cm (for dish antenna) or 132 cm (for sector antenna) from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80 and 160 MHz bandwidth modes.

Class III Permissive Change: Adds the frequencies 6835 MHz with 80 MHz bandwidth and 6795 MHz with 160 MHz bandwidth in U-NII Band 7 for 6SD and 6FC modes via software update.


EP: Output power is Effective Isotropic Radiated Power (EIRP)
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application RMXfd74xrIh3aucJcJVSOg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Cambium Networks Inc.
3800 Golf Road Suite 360
Rolling Meadows, IL 60008
United States
  Date of Grant: 08/27/2024

Application Dated: 08/08/2024
 
Attention: Steven Payne , R.F. Principle Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Z8H89FT0069
Name of Grantee:  Cambium Networks Inc.
Equipment Class: 15E 6 GHz Standard Power Access Point
Notes: ePMP 6 GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EP MO 15E 5955.0  -  6415.0 3.926  
EP MO 15E 6535.0  -  6855.0 3.908  

Power listed is EIRP. Software Defined Radio. Professional installation is required. Device operates with specific antennas in MIMO configurations as described in this filing. The antennas used for this device must be installed to provide a separation distance of at least 371 cm (for dish antenna) or 132 cm (for sector antenna) from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80 and 160 MHz bandwidth modes.

Class III Permissive Change: Adds the frequencies 6835 MHz with 80 MHz bandwidth and 6795 MHz with 160 MHz bandwidth in U-NII Band 7 for 6SD and 6FC modes via software update.


EP: Output power is Effective Isotropic Radiated Power (EIRP)
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application Hx1eUoyfP+xwAFO3/OB5ww==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 04/29/2024

Application Dated: 04/26/2024
Cambium Networks Inc.
3800 Golf Road
Suite 360
Rolling Meadows, IL 60008
 
Attention: Steven Payne , R.F. Principle Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Z8H89FT0069
Name of Grantee:  Cambium Networks Inc.
Equipment Class: 15E 6 GHz Standard Client Device
Notes: ePMP 6 GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EP MO 15E 5955.0  -  6415.0 3.631  
EP MO 15E 6535.0  -  6855.0 2.421  

Power listed is EIRP. Device operates with specific antennas as described in this filing. Professional installation is required. The antennas used for this device must be installed to provide a separation distance of at least 371 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80 and 160 MHz bandwidth modes.

Class III Permissive Change:

1. Adds 6 GHz Standard Power Access Point (6SD), Fixed Client (6FC) and Standard Client (6FX) operational modes via software update.

2. Add a new directional Sector Antenna for 5 GHz and 6 GHz which is of the same antenna type but lower gain than that of the original application.


EP: Output power is Effective Isotropic Radiated Power (EIRP)
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application Hx1eUoyfP+xwAFO3/OB5ww==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Cambium Networks Inc.
3800 Golf Road Suite 360
Rolling Meadows, IL 60008
United States
  Date of Grant: 04/29/2024

Application Dated: 04/26/2024
 
Attention: Steven Payne , R.F. Principle Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Z8H89FT0069
Name of Grantee:  Cambium Networks Inc.
Equipment Class: 15E 6 GHz Standard Client Device
Notes: ePMP 6 GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EP MO 15E 5955.0  -  6415.0 3.631  
EP MO 15E 6535.0  -  6855.0 2.421  

Power listed is EIRP. Device operates with specific antennas as described in this filing. Professional installation is required. The antennas used for this device must be installed to provide a separation distance of at least 371 cm from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80 and 160 MHz bandwidth modes.

Class III Permissive Change:

1. Adds 6 GHz Standard Power Access Point (6SD), Fixed Client (6FC) and Standard Client (6FX) operational modes via software update.

2. Add a new directional Sector Antenna for 5 GHz and 6 GHz which is of the same antenna type but lower gain than that of the original application.


EP: Output power is Effective Isotropic Radiated Power (EIRP)
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application BgWgTh/LL8M8Lh4mktEDEg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 08/28/2024

Application Dated: 08/27/2024
Cambium Networks Inc.
3800 Golf Road
Suite 360
Rolling Meadows, IL 60008
 
Attention: Steven Payne , R.F. Principle Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Z8H89FT0069
Name of Grantee:  Cambium Networks Inc.
Equipment Class: 15E 6 GHz Fixed Client
Notes: ePMP 6 GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EP MO 15E 5955.0  -  6415.0 3.926  
EP MO 15E 6535.0  -  6855.0 3.908  

Power listed is EIRP. Software Defined Radio. Professional installation is required. Device operates with specific antennas in MIMO configurations as described in this filing. The antennas used for this device must be installed to provide a separation distance of at least 371 cm (for dish antenna) or 132 cm (for sector antenna) from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80 and 160 MHz bandwidth modes.

Class III Permissive Change: Adds the frequencies 6835 MHz with 80 MHz bandwidth and 6795 MHz with 160 MHz bandwidth in U-NII Band 7 for 6SD and 6FC modes via software update.


EP: Output power is Effective Isotropic Radiated Power (EIRP)
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application BgWgTh/LL8M8Lh4mktEDEg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Cambium Networks Inc.
3800 Golf Road Suite 360
Rolling Meadows, IL 60008
United States
  Date of Grant: 08/28/2024

Application Dated: 08/27/2024
 
Attention: Steven Payne , R.F. Principle Staff Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  Z8H89FT0069
Name of Grantee:  Cambium Networks Inc.
Equipment Class: 15E 6 GHz Fixed Client
Notes: ePMP 6 GHz Force 4600C SM, ePMP 4600L 6 GHz 2x2 Access Point
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EP MO 15E 5955.0  -  6415.0 3.926  
EP MO 15E 6535.0  -  6855.0 3.908  

Power listed is EIRP. Software Defined Radio. Professional installation is required. Device operates with specific antennas in MIMO configurations as described in this filing. The antennas used for this device must be installed to provide a separation distance of at least 371 cm (for dish antenna) or 132 cm (for sector antenna) from all persons and must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users must be provided with installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has 20, 40, 80 and 160 MHz bandwidth modes.

Class III Permissive Change: Adds the frequencies 6835 MHz with 80 MHz bandwidth and 6795 MHz with 160 MHz bandwidth in U-NII Band 7 for 6SD and 6FC modes via software update.


EP: Output power is Effective Isotropic Radiated Power (EIRP)
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: