FCC ID ZAKLIB-V320
Wireless Ethernet Bridge
by Sub10 Systems Ltd
Grantee Code: ZAK Product Code: LIBV320
Latest application date: 2011-04-05
FCC ID Device Details
| FCC ID | ZAKLIB-V320 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | ZAK |
| Product Code | LIBV320 |
| Applicant Business | Sub10 Systems Ltd 🇬🇧 |
| Related Domains | |
| Equipment Class | Wireless Ethernet Bridge |
| Test Firm | CETECOM ICT Services GmbH |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 59500-62000 MHz | Change in identification of presently authorized equipment. Original FCC ID: TTDSL60401 Grant Date: 10/21/2009 | 2011-04-05 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| External appearance | External Photos | 2011-04-05 | PDF 2 MB |
| New labels | ID Label/Location Info | 2011-04-05 | PDF 2.2 MB |
| Original labels | ID Label/Location Info | 2011-04-05 | PDF 102 KB |
| Agent Authorisation | Cover Letter(s) | 2011-04-05 | PDF 28.7 KB |
| Letter from new applicant | Cover Letter(s) | 2011-04-05 | PDF 29.1 KB |
| Letter from original applicant | Cover Letter(s) | 2011-04-05 | PDF 176.5 KB |
Application Information
| Application ID | +Cg9PdAZoPPaYxjkLjB39g== |
|---|---|
| Final Action Date | 2011-04-05 |
| Application Purpose | Change in identification of presently authorized equipment. Original FCC ID: TTDSL60401 Grant Date: 10/21/2009 |
| Applicant FRN | 0020624110 |
| Model | LIB-V320 |
| Frequency Range | 59500-62000 MHz |
| Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter |
| Device Description | Wireless Ethernet Bridge |
| Responsible Party | Mark Stevens, Chief Technical Officer, mark.stevens@sub10systems.com |
| Agent | Trevor Trevor Trevor, Datavilla Ltd, trevor.hizzard@datavilla.co.uk |
| Technical Contact | Mark Stevens, Sub10 Systems Ltd, mark.stevens@sub10systems.com |
| Non-Technical Contact | Grant Grafton, Sub10 Systems Ltd, grant.grafton@sub10systems.com |
| Test Firm | Gerald Schmidt, CETECOM ICT Services GmbH, tcb@cetecom.com |
| TCB Email | hotline@atcb.com |
| TCB Scope | A2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Only integral directional 4 field patch antenna as documented in this filing must be used. The antenna used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 2m from all persons. Users and installers must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. This device must be supplied with an A.C. power cord which incorporates ferrite cores equal in quantity and type to those used during certification testing to ensure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| +Cg9PdAZoPPaYxjkLjB39g== | 2011-04-05 | Change in identification of presently authorized equipment. Original FCC ID: TTDSL60401 Grant Date: 10/21/2009 |
Equipment Authorization
| Frequency | Rules |
|---|---|
| 59500-62000 MHz | 15C |
Grants
TCB Grant - Application +Cg9PdAZoPPaYxjkLjB39g==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 04/05/2011 Application Dated: 04/05/2011 |
| Sub10 Systems Ltd |
| Ash House |
| Canal Way |
| Kingsteignton, Newton Abbot, TQ12 3RZ United Kingdom |
| Attention: Mark Stevens , Chief Technical Officer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZAKLIB-V320 |
| Name of Grantee: | Sub10 Systems Ltd |
| Equipment Class: | Part 15 Low Power Communication Device Transmitter |
| Notes: | Wireless Ethernet Bridge |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 59500.0 - 62000.0 |
| Only integral directional 4 field patch antenna as documented in this filing must be used. The antenna used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 2m from all persons. Users and installers must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. This device must be supplied with an A.C. power cord which incorporates ferrite cores equal in quantity and type to those used during certification testing to ensure compliance. |
EAS Grant - Application +Cg9PdAZoPPaYxjkLjB39g==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Sub10 Systems Ltd Ash House Canal Way Kingsteignton, Newton Abbot, TQ12 3RZ United Kingdom |
Date of Grant: 04/05/2011 Application Dated: 04/05/2011 |
| Attention: Mark Stevens , Chief Technical Officer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZAKLIB-V320 |
| Name of Grantee: | Sub10 Systems Ltd |
| Equipment Class: | Part 15 Low Power Communication Device Transmitter |
| Notes: | Wireless Ethernet Bridge |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 59500.0 - 62000.0 |
| Only integral directional 4 field patch antenna as documented in this filing must be used. The antenna used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 2m from all persons. Users and installers must be provided with antenna installation instructions and transmitter operating conditions to satisfy RF exposure compliance. This device must be supplied with an A.C. power cord which incorporates ferrite cores equal in quantity and type to those used during certification testing to ensure compliance. |
| Mail To: |