FCC ID ZC4X220

smartphone

by Corporativo Lanix S.A. de C.V.

Grantee Code: ZC4   Product Code: X220
Latest application date: 2017-02-17

FCC ID Device Details

FCC IDZC4X220
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeZC4
Product CodeX220
Applicant BusinessCorporativo Lanix S.A. de C.V. 🇲🇽
Related Domains lanix.com
Equipment Classsmartphone
Test FirmBureau Veritas Shenzhen Co., Ltd. Dongguan Branch

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.2-848.8 MHzOriginal Equipment2017-02-17
2412-2462 MHzOriginal Equipment2017-02-17
2402-2480 MHzOriginal Equipment2017-02-17

Exhibits

DocumentTypeAvailableFile
User manual_R1.pdfUsers Manual2017-08-16PDF 314.6 KB
Internal Photos.pdfInternal Photos2017-08-16PDF 1.2 MB
External Photos.pdfExternal Photos2017-08-16PDF 541.9 KB
Label Location_R1.pdfID Label/Location Info2017-02-17PDF 67.4 KB
Label location - FCC Label location declaration.pdfID Label/Location Info2017-02-17PDF 133.1 KB
Label.pdfID Label/Location Info2017-02-17PDF 95.9 KB
Test setup photos - FCC 15B Test Setup photos.pdfTest Setup Photos2017-08-16PDF 387.5 KB
Test setup photos - FCC RF Test Setup photos.pdfTest Setup Photos2017-08-16PDF 571.8 KB
Test setup photos - SAR.pdfTest Setup Photos2017-08-16PDF 552.7 KB
Test report_15B Report_R1.pdfTest Report2017-02-17PDF 264.4 KB
Test report_BT EDR Report.pdfTest Report2017-02-17PDF 1,012.9 KB
Test report_Part 22 Report_R1.pdfTest Report2017-02-17PDF 1.5 MB
Test report_Part 24 Report.pdfTest Report2017-02-17PDF 1.5 MB
Test report_WIFI(11n20) Report_R1.pdfTest Report2017-02-17PDF 876.1 KB
Confidentiality request - Long term.pdfCover Letter(s)2017-02-17PDF 235.1 KB
Cover letter - Agent authorization.pdfCover Letter(s)2017-02-17PDF 202.6 KB
Cover letter - BT,WLAN Declaration.pdfCover Letter(s)2017-02-17PDF 144 KB
Cover letter - WLAN channel declaration.pdfCover Letter(s)2017-02-17PDF 128.2 KB
SAR Report_Part 1.pdfRF Exposure Info2017-02-17PDF 3.4 MB
SAR Report_Part 2.pdfRF Exposure Info2017-02-17PDF 3.9 MB
Block diagram_R1.pdf Metadata onlyBlock DiagramPDF 114 KB
Schematics_R1.pdf Metadata onlySchematicsPDF 393.4 KB
Operational Description.pdf Metadata onlyOperational DescriptionPDF 22.4 KB
Parts list_BOM List_R1.pdf Metadata onlyParts List/Tune Up InfoPDF 90.3 KB
Tune up procedure_R1.pdf Metadata onlyParts List/Tune Up InfoPDF 147.9 KB

Application Information

Application IDwzfygGZ59NZ9FQ2kv/ZeJg==
Final Action Date2017-02-17
Application PurposeOriginal Equipment
Applicant FRN0020679627
ModelX220
Frequency Range824.2-848.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device Descriptionsmartphone
Responsible PartyMax Gaxiola, Product Manager, max.gaxiola@lanix.com , 6621090800
AgentDaniel Daniel Daniel, Bureau Veritas Consumer Products Services (H.K.) L, daniel-ch.lee@tw.bureauveritas.com , 88633183232
Test FirmAlec Hu, Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch, alec.hu@cn.bureauveritas.com , 86-769-85935656
TCB Emailtcb@us.bureauveritas.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date08/16/2017
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is ERP/EIRP. This antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing and/or in accordance with FCC multi-transmitter product guidelines. SAR compliance has been demonstrated as described in this filing. SAR compliance of body-worn operating configurations is restricted to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the user's body. End users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn accessory, Hotspot and highest simultaneous transmission use conditions are 0.65W/kg, 0.90W/kg, 0.90W/kg, 1.31W/kg respectively.

Applications

Application IDDatePurpose
wzfygGZ59NZ9FQ2kv/ZeJg==2017-02-17Original Equipment
uA1heX9kqPk1s0mr5VKYNA==2017-02-17Original Equipment
IdJnEvIbscGij4Qdf8Mkmg==2017-02-17Original Equipment
IKO0AhUuNqXD0dbhkudTBQ==2017-02-17Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
15BCC
824.2-848.8 MHz0.3720.0132ppm248KGXW22H
824.2-848.8 MHz0.1760.0128ppm243KG7W22H
826.4-846.6 MHz0.0370.0128ppm4M12F9W22H
1850.2-1909.8 MHz0.8330.0064ppm247KGXW24E
1850.2-1909.8 MHz0.5210.0063ppm247KG7W24E
1852.4-1907.6 MHz0.2020.0055ppm4M12F9W24E
2402-2480 MHz0.003400015CCC
2412-2462 MHz0.036900015CCC

Grants

TCB Grant - Application wzfygGZ59NZ9FQ2kv/ZeJg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 02/17/2017

Application Dated: 02/17/2017
Corporativo Lanix S.A. de C.V.
Carrtera internacional Hermosillo-Nogales Km 8.5
Hermosillo, 83160
Mexico
 
Attention: Max Gaxiola , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZC4X220
Name of Grantee:  Corporativo Lanix S.A. de C.V.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: smartphone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.372 0.0132  PM 248KGXW
22H 824.2  -  848.8 0.176 0.0128  PM 243KG7W
22H 826.4  -  846.6 0.037 0.0128  PM 4M12F9W
24E 1850.2  -  1909.8 0.833 0.0064  PM 247KGXW
24E 1850.2  -  1909.8 0.521 0.0063  PM 247KG7W
24E 1852.4  -  1907.6 0.202 0.0055  PM 4M12F9W

Output power listed is ERP/EIRP. This antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing and/or in accordance with FCC multi-transmitter product guidelines. SAR compliance has been demonstrated as described in this filing. SAR compliance of body-worn operating configurations is restricted to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the user's body. End users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn accessory, Hotspot and highest simultaneous transmission use conditions are 0.65W/kg, 0.90W/kg, 0.90W/kg, 1.31W/kg respectively.

EAS Grant - Application wzfygGZ59NZ9FQ2kv/ZeJg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Corporativo Lanix S.A. de C.V.
Carrtera internacional Hermosillo-Nogales Km 8.5
Hermosillo, 83160
Mexico
  Date of Grant: 02/17/2017

Application Dated: 02/17/2017
 
Attention: Max Gaxiola , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZC4X220
Name of Grantee:  Corporativo Lanix S.A. de C.V.
Equipment Class: PCS Licensed Transmitter held to ear
Notes: smartphone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.372 0.0132  PM 248KGXW
22H 824.2  -  848.8 0.176 0.0128  PM 243KG7W
22H 826.4  -  846.6 0.037 0.0128  PM 4M12F9W
24E 1850.2  -  1909.8 0.833 0.0064  PM 247KGXW
24E 1850.2  -  1909.8 0.521 0.0063  PM 247KG7W
24E 1852.4  -  1907.6 0.202 0.0055  PM 4M12F9W

Output power listed is ERP/EIRP. This antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing and/or in accordance with FCC multi-transmitter product guidelines. SAR compliance has been demonstrated as described in this filing. SAR compliance of body-worn operating configurations is restricted to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the user's body. End users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn accessory, Hotspot and highest simultaneous transmission use conditions are 0.65W/kg, 0.90W/kg, 0.90W/kg, 1.31W/kg respectively.



TCB Grant - Application uA1heX9kqPk1s0mr5VKYNA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 02/17/2017

Application Dated: 02/17/2017
Corporativo Lanix S.A. de C.V.
Carrtera internacional Hermosillo-Nogales Km 8.5
Hermosillo, 83160
Mexico
 
Attention: Max Gaxiola , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZC4X220
Name of Grantee:  Corporativo Lanix S.A. de C.V.
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: smartphone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application uA1heX9kqPk1s0mr5VKYNA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Corporativo Lanix S.A. de C.V.
Carrtera internacional Hermosillo-Nogales Km 8.5
Hermosillo, 83160
Mexico
  Date of Grant: 02/17/2017

Application Dated: 02/17/2017
 
Attention: Max Gaxiola , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZC4X220
Name of Grantee:  Corporativo Lanix S.A. de C.V.
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: smartphone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application IKO0AhUuNqXD0dbhkudTBQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 02/17/2017

Application Dated: 02/17/2017
Corporativo Lanix S.A. de C.V.
Carrtera internacional Hermosillo-Nogales Km 8.5
Hermosillo, 83160
Mexico
 
Attention: Max Gaxiola , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZC4X220
Name of Grantee:  Corporativo Lanix S.A. de C.V.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: smartphone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0034  

Power listed is conducted. This antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing and/or in accordance with FCC multi-transmitter product guidelines. SAR compliance has been demonstrated as described in this filing. SAR compliance of body-worn operating configurations is restricted to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the user's body. End users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for simultaneous transmission use condition is 0.97W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application IKO0AhUuNqXD0dbhkudTBQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Corporativo Lanix S.A. de C.V.
Carrtera internacional Hermosillo-Nogales Km 8.5
Hermosillo, 83160
Mexico
  Date of Grant: 02/17/2017

Application Dated: 02/17/2017
 
Attention: Max Gaxiola , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZC4X220
Name of Grantee:  Corporativo Lanix S.A. de C.V.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: smartphone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0034  

Power listed is conducted. This antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing and/or in accordance with FCC multi-transmitter product guidelines. SAR compliance has been demonstrated as described in this filing. SAR compliance of body-worn operating configurations is restricted to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the user's body. End users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for simultaneous transmission use condition is 0.97W/kg respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application IdJnEvIbscGij4Qdf8Mkmg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bureau Veritas Consumer Products Services, Inc.
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 02/17/2017

Application Dated: 02/17/2017
Corporativo Lanix S.A. de C.V.
Carrtera internacional Hermosillo-Nogales Km 8.5
Hermosillo, 83160
Mexico
 
Attention: Max Gaxiola , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZC4X220
Name of Grantee:  Corporativo Lanix S.A. de C.V.
Equipment Class: Digital Transmission System
Notes: smartphone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0369  

Power listed is conducted. This antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing and/or in accordance with FCC multi-transmitter product guidelines. SAR compliance has been demonstrated as described in this filing. SAR compliance of body-worn operating configurations is restricted to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the user's body. End users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn accessory, Hotspot and highest simultaneous transmission use conditions are 0.66W/kg, 0.23W/kg, 0.23W/kg, 1.31W/kg respectively. This device supports 20MHz bandwidth mode.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application IdJnEvIbscGij4Qdf8Mkmg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Corporativo Lanix S.A. de C.V.
Carrtera internacional Hermosillo-Nogales Km 8.5
Hermosillo, 83160
Mexico
  Date of Grant: 02/17/2017

Application Dated: 02/17/2017
 
Attention: Max Gaxiola , Product Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZC4X220
Name of Grantee:  Corporativo Lanix S.A. de C.V.
Equipment Class: Digital Transmission System
Notes: smartphone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0369  

Power listed is conducted. This antenna(s) used for this transmitter must not be collocated or operating in conjunction with any other antenna or transmitter, except the collocation as described in this filing and/or in accordance with FCC multi-transmitter product guidelines. SAR compliance has been demonstrated as described in this filing. SAR compliance of body-worn operating configurations is restricted to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the user's body. End users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn accessory, Hotspot and highest simultaneous transmission use conditions are 0.66W/kg, 0.23W/kg, 0.23W/kg, 1.31W/kg respectively. This device supports 20MHz bandwidth mode.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: