FCC ID ZIMH40L
Ambulator electrocardiograph monitor
by TZ MEDICAL INC
Grantee Code: ZIM Product Code: H40L
Latest application date: 2020-05-11
FCC ID Device Details
| FCC ID | ZIMH40L |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | ZIM |
| Product Code | H40L |
| Applicant Business | TZ MEDICAL INC 🇺🇸 |
| Related Domains | |
| Equipment Class | Ambulator electrocardiograph monitor |
| Test Firm | CETECOM Inc. |
Linked Records
Barcode records decoded from published FCC label exhibits or linked by an explicit FCC ID reference on a product page.
| UPC / GTIN | Linked product |
|---|---|
| 811331011548 UPC-A · GTIN-14 00811331011548 | Ambulator electrocardiograph monitor Brand: TZ MEDICAL INC · Model: H40L Source: FCC label |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 699.7-715.3 MHz | Original Equipment | 2020-05-11 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Information Metadata only | Users Manual | 2020-08-04 | PDF 145.5 KB |
| User Manual | Users Manual | 2020-08-04 | PDF 2.5 MB |
| Photos Internal | Internal Photos | 2020-08-04 | PDF 2.2 MB |
| Photos External | External Photos | 2020-08-04 | PDF 174.2 KB |
| label Information | ID Label/Location Info | 2020-05-11 | PDF 809 KB |
| Integrated Module Report 1-1 | Test Report | 2020-05-11 | PDF 3.6 MB |
| Test Report Integrated Module 1-2 | Test Report | 2020-05-11 | PDF 2.4 MB |
| Test Report Integrated Module 2-1 | Test Report | 2020-05-11 | PDF 4.8 MB |
| Test Report Integrated Module 2-2 | Test Report | 2020-05-11 | PDF 4.4 MB |
| Test Report SAR | RF Exposure Info | 2020-05-11 | PDF 1.5 MB |
| Test Report Sar Annex A | RF Exposure Info | 2020-05-11 | PDF 2.7 MB |
| Test Report Sar Annex B | RF Exposure Info | 2020-05-11 | PDF 728.2 KB |
| Test Report Sar Annex C-1 | RF Exposure Info | 2020-05-11 | PDF 4.7 MB |
| Test Report Sar Annex C-2 Metadata only | RF Exposure Info | 2020-05-11 | PDF 4.7 MB |
| Test Report Sar Annex C_2 | RF Exposure Info | 2020-05-11 | PDF 4.9 MB |
| Confidentiality Letter LTC | Cover Letter(s) | 2020-05-11 | PDF 271.4 KB |
| Confidentiality Letter STC | Cover Letter(s) | 2020-05-11 | PDF 278.3 KB |
| LOA and Anti drug statment | Cover Letter(s) | 2020-05-11 | PDF 169.6 KB |
| Letter for validity of module reports | Cover Letter(s) | 2020-05-11 | PDF 453.9 KB |
| letter pertaining to duty cycle | Cover Letter(s) | 2020-05-11 | PDF 414.3 KB |
| Block diagram Metadata only | Block Diagram | PDF 32.6 KB | |
| Schematics Metadata only | Schematics | PDF 2.7 MB | |
| Op Description Metadata only | Operational Description | PDF 394 KB | |
| Part List Metadata only | Parts List/Tune Up Info | PDF 352.8 KB |
Application Information
| Application ID | vWQ5UP4WQUH9g1VsDI1oEg== |
|---|---|
| Final Action Date | 2020-05-11 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0020820486 |
| Model | H40L |
| Frequency Range | 699.7-715.3 MHz |
| Equipment Class | PCT - PCS Licensed Transmitter worn on body |
| Device Description | Ambulator electrocardiograph monitor |
| Responsible Party | John Moore, Electrical Engineer, jmoore@tzmedical.com |
| Test Firm | Kevin Wang, CETECOM Inc., kevin.wang@cetecom.com |
| TCB Email | james.donnellan@cetecom.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 08/04/2020 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is EIRP above 1 GHz and ERP below 1 GHz. The equipment fulfills the requirement for portable use. The maximum reported body SAR is 1.31 W/kg per 1g of tissue. The maximum reported extremity SAR is 1.76 W/kg per 10g of tissue |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| vWQ5UP4WQUH9g1VsDI1oEg== | 2020-05-11 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 699.7-715.3 MHz | 0.141 | 0.1ppm | 1M10W7D | 27 | BC |
| 704-711 MHz | 0.138 | 0.1ppm | 9M04W7D | 27 | BC |
| 826.4-846.6 MHz | 0.032 | 0.1ppm | 4M09F9W | 22H | BC |
| 829-844 MHz | 0.031 | 0.1ppm | 9M04W7D | 22H | BC |
| 1712.4-1752.6 MHz | 0.228 | 0.1ppm | 4M09F9W | 27 | BC |
| 1720-1745 MHz | 0.21 | 0.1ppm | 17M9W7D | 27 | BC |
| 1850.2-1909.7 MHz | 0.988 | 0.1ppm | 248KGXW | 24E | BC |
| 1852.4-1907.6 MHz | 0.182 | 0.1ppm | 4M09F9W | 24E | BC |
| 1860-1900.1 MHz | 0.156 | 0.1ppm | 18M1W7D | 24E | BC |
| 2510-2560 MHz | 0.233 | 0.1ppm | 18M1W7D | 27 | BC |
Grants
TCB Grant - Application vWQ5UP4WQUH9g1VsDI1oEg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CETECOM Inc. 411 Dixon Landing Road Milpitas, CA 95035 |
Date of Grant: 05/11/2020 Application Dated: 05/06/2020 |
| TZ MEDICAL INC |
| 17750 SW UPPER BOONES FERRY RD |
| SUITE #150 |
| PORTLAND, OR 97224 |
| Attention: John Moore , Electrical Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZIMH40L |
| Name of Grantee: | TZ MEDICAL INC |
| Equipment Class: | PCS Licensed Transmitter worn on body |
| Notes: | Ambulator electrocardiograph monitor |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 22H | 824.2 - 848.7 | 0.443 | 0.1 PM | 247KGXW |
| BC | 24E | 1850.2 - 1909.7 | 0.988 | 0.1 PM | 248KGXW |
| BC | 22H | 826.4 - 846.6 | 0.032 | 0.1 PM | 4M09F9W |
| BC | 24E | 1852.4 - 1907.6 | 0.182 | 0.1 PM | 4M09F9W |
| BC | 27 | 1712.4 - 1752.6 | 0.228 | 0.1 PM | 4M09F9W |
| BC | 24E | 1860.0 - 1900.1 | 0.156 | 0.1 PM | 18M1W7D |
| BC | 27 | 1720.0 - 1745.0 | 0.21 | 0.1 PM | 17M9W7D |
| BC | 22H | 829.0 - 844.0 | 0.031 | 0.1 PM | 9M04W7D |
| BC | 27 | 699.7 - 715.3 | 0.141 | 0.1 PM | 1M10W7D |
| BC | 27 | 704.0 - 711.0 | 0.138 | 0.1 PM | 9M04W7D |
| BC | 27 | 2510.0 - 2560.0 | 0.233 | 0.1 PM | 18M1W7D |
| Power listed is EIRP above 1 GHz and ERP below 1 GHz. The equipment fulfills the requirement for portable use. The maximum reported body SAR is 1.31 W/kg per 1g of tissue. The maximum reported extremity SAR is 1.76 W/kg per 10g of tissue |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
EAS Grant - Application vWQ5UP4WQUH9g1VsDI1oEg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
TZ MEDICAL INC 17750 SW UPPER BOONES FERRY RD SUITE #150 PORTLAND, OR 97224 United States |
Date of Grant: 05/11/2020 Application Dated: 05/06/2020 |
| Attention: John Moore , Electrical Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZIMH40L |
| Name of Grantee: | TZ MEDICAL INC |
| Equipment Class: | PCS Licensed Transmitter worn on body |
| Notes: | Ambulator electrocardiograph monitor |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 22H | 824.2 - 848.7 | 0.443 | 0.1 PM | 247KGXW |
| BC | 24E | 1850.2 - 1909.7 | 0.988 | 0.1 PM | 248KGXW |
| BC | 22H | 826.4 - 846.6 | 0.032 | 0.1 PM | 4M09F9W |
| BC | 24E | 1852.4 - 1907.6 | 0.182 | 0.1 PM | 4M09F9W |
| BC | 27 | 1712.4 - 1752.6 | 0.228 | 0.1 PM | 4M09F9W |
| BC | 24E | 1860.0 - 1900.1 | 0.156 | 0.1 PM | 18M1W7D |
| BC | 27 | 1720.0 - 1745.0 | 0.21 | 0.1 PM | 17M9W7D |
| BC | 22H | 829.0 - 844.0 | 0.031 | 0.1 PM | 9M04W7D |
| BC | 27 | 699.7 - 715.3 | 0.141 | 0.1 PM | 1M10W7D |
| BC | 27 | 704.0 - 711.0 | 0.138 | 0.1 PM | 9M04W7D |
| BC | 27 | 2510.0 - 2560.0 | 0.233 | 0.1 PM | 18M1W7D |
| Power listed is EIRP above 1 GHz and ERP below 1 GHz. The equipment fulfills the requirement for portable use. The maximum reported body SAR is 1.31 W/kg per 1g of tissue. The maximum reported extremity SAR is 1.76 W/kg per 10g of tissue |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
| Mail To: |