FCC ID ZIMH40M
Ambulatory electrocardiograph monitor
by TZ MEDICAL INC
Grantee Code: ZIM Product Code: H40M
Latest application date: 2017-06-06
FCC ID Device Details
| FCC ID | ZIMH40M |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | ZIM |
| Product Code | H40M |
| Applicant Business | TZ MEDICAL INC 🇺🇸 |
| Related Domains | |
| Equipment Class | Ambulatory electrocardiograph monitor |
| Test Firm | CETECOM Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.2-848.8 MHz | Original Equipment | 2017-06-06 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2017-12-03 | PDF 1.3 MB |
| Internal Photographs | Internal Photos | 2017-12-03 | PDF 271.8 KB |
| External | External Photos | 2017-12-03 | PDF 131.1 KB |
| Label and Label Information | ID Label/Location Info | 2017-06-06 | PDF 365.4 KB |
| Test Setup Photographs | Test Setup Photos | 2017-12-03 | PDF 1.1 MB |
| RF Test Rport | Test Report | 2017-06-06 | PDF 4.4 MB |
| SAR Test Report | RF Exposure Info | 2017-06-06 | PDF 978.8 KB |
| Test Report Metadata only | Test Report | 2017-06-06 | PDF 978.8 KB |
| Authorization Form | Attestation Statements | 2017-06-06 | PDF 434.7 KB |
| Confidentiality Request Form | Cover Letter(s) | 2017-06-06 | PDF 290.3 KB |
| Block Diagram Metadata only | Block Diagram | PDF 32.2 KB | |
| Schematics Metadata only | Schematics | PDF 2.7 MB | |
| Operational Description Metadata only | Operational Description | PDF 287.2 KB | |
| Tune Up Procedure Metadata only | Parts List/Tune Up Info | PDF 378.7 KB |
Application Information
| Application ID | VICK+o5qsyTNXiHEibtPAg== |
|---|---|
| Final Action Date | 2017-06-06 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0020820486 |
| Model | H40M |
| Frequency Range | 824.2-848.8 MHz |
| Equipment Class | PCT - PCS Licensed Transmitter worn on body |
| Device Description | Ambulatory electrocardiograph monitor |
| Responsible Party | John Moore, Electrical Engineer, jmoore@tzmedical.com |
| Test Firm | Kevin Wang, CETECOM Inc., kevin.wang@cetecom.com |
| TCB Email | franz.engert@cetecom.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 12/03/2017 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Powers listed are ERP below 1 GHz and EIRP above 1 GHz. The equipment fulfills the requirement for portable use. The maximum reported body SAR is 1.06 W/kg per 1 g of tissue.The maximum reported extremity SAR is 1.12 W/kg per 10g of tissue. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| VICK+o5qsyTNXiHEibtPAg== | 2017-06-06 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application VICK+o5qsyTNXiHEibtPAg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CETECOM Inc. 411 Dixon Landing Road Milpitas, CA 95035 |
Date of Grant: 06/06/2017 Application Dated: 06/06/2017 |
| TZ MEDICAL INC |
| 17750 SW UPPER BOONES FERRY RD |
| SUITE #150 |
| PORTLAND, OR 97224 |
| Attention: John Moore , Electrical Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZIMH40M |
| Name of Grantee: | TZ MEDICAL INC |
| Equipment Class: | PCS Licensed Transmitter worn on body |
| Notes: | Ambulatory electrocardiograph monitor |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 22H | 824.2 - 848.8 | 1.53 | 25.0 Hz | 244KGXW |
| BC | 22H | 824.2 - 848.8 | 0.38 | 18.0 Hz | 253KG7W |
| BC | 22H | 826.4 - 846.6 | 0.19 | 21.0 Hz | 4M07F9W |
| BC | 24E | 1850.2 - 1909.8 | 1.73 | 10.0 Hz | 244KGXW |
| BC | 24E | 1850.0 - 1909.8 | 0.68 | 22.0 Hz | 247KG7W |
| BC | 24E | 1852.04 - 1907.6 | 0.42 | 21.0 Hz | 4M07F9W |
| Powers listed are ERP below 1 GHz and EIRP above 1 GHz. The equipment fulfills the requirement for portable use. The maximum reported body SAR is 1.06 W/kg per 1 g of tissue.The maximum reported extremity SAR is 1.12 W/kg per 10g of tissue. |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
EAS Grant - Application VICK+o5qsyTNXiHEibtPAg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
TZ MEDICAL INC 17750 SW UPPER BOONES FERRY RD SUITE #150 PORTLAND, OR 97224 United States |
Date of Grant: 06/06/2017 Application Dated: 06/06/2017 |
| Attention: John Moore , Electrical Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZIMH40M |
| Name of Grantee: | TZ MEDICAL INC |
| Equipment Class: | PCS Licensed Transmitter worn on body |
| Notes: | Ambulatory electrocardiograph monitor |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BC | 22H | 824.2 - 848.8 | 1.53 | 25.0 Hz | 244KGXW |
| BC | 22H | 824.2 - 848.8 | 0.38 | 18.0 Hz | 253KG7W |
| BC | 22H | 826.4 - 846.6 | 0.19 | 21.0 Hz | 4M07F9W |
| BC | 24E | 1850.2 - 1909.8 | 1.73 | 10.0 Hz | 244KGXW |
| BC | 24E | 1850.0 - 1909.8 | 0.68 | 22.0 Hz | 247KG7W |
| BC | 24E | 1852.04 - 1907.6 | 0.42 | 21.0 Hz | 4M07F9W |
| Powers listed are ERP below 1 GHz and EIRP above 1 GHz. The equipment fulfills the requirement for portable use. The maximum reported body SAR is 1.06 W/kg per 1 g of tissue.The maximum reported extremity SAR is 1.12 W/kg per 10g of tissue. |
| BC: | The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed. |
| Mail To: |