FCC ID ZLZ-MRR8860

Wireless LAN Router

by Shenzhen Mindray BIO-Medical electronics Co.,LTD.

Grantee Code: ZLZ   Product Code: MRR8860
Latest application date: 2024-09-17

FCC ID Device Details

FCC IDZLZ-MRR8860
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeZLZ
Product CodeMRR8860
Applicant BusinessShenzhen Mindray BIO-Medical electronics Co.,LTD. 🇨🇳
Related Domains mindray.com
Equipment ClassWireless LAN Router
Test FirmWALTEK TESTING GROUP CO., LTD.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2024-09-17
5180-5240 MHzOriginal Equipment2024-09-17

Exhibits

DocumentTypeAvailableFile
user manualUsers Manual2024-09-17PDF 2.5 MB
internal photosInternal Photos2024-09-17PDF 3.8 MB
External photosExternal Photos2024-09-17PDF 1.7 MB
labelID Label/Location Info2024-09-17PDF 218.3 KB
test setup photosTest Setup Photos2024-09-17PDF 1.2 MB
antenna specificationTest Report2024-09-17PDF 576.6 KB
test reportTest Report2024-09-17PDF 2.4 MB
test report_part 1Test Report2024-09-17PDF 5 MB
test report_part 2Test Report2024-09-17PDF 4.5 MB
Attestation Section 2.911(d)(5)(i)Attestation Statements2024-09-17PDF 18.7 KB
Attestation Section 2.911(d)(5)(ii)Attestation Statements2024-09-17PDF 20.1 KB
US Agent letterAttestation Statements2024-09-17PDF 110.6 KB
POA letterCover Letter(s)2024-09-17PDF 32.5 KB
confidentiality letterCover Letter(s)2024-09-17PDF 34.9 KB
RF exposure reportRF Exposure Info2024-09-17PDF 201.3 KB
Block Diagram Metadata onlyBlock DiagramPDF 125.3 KB
block diagram Metadata onlyBlock DiagramPDF 125.3 KB
Schematics Metadata onlySchematicsPDF 1 MB
schematics Metadata onlySchematicsPDF 1 MB
Operational Description Metadata onlyOperational DescriptionPDF 93.6 KB
operation description Metadata onlyOperational DescriptionPDF 93.6 KB

Application Information

Application IDiEUSZevse9JjhimnsqhtAw==
Final Action Date2024-09-17
Application PurposeOriginal Equipment
Applicant FRN0020888061
ModelMRR8860
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionWireless LAN Router
Responsible PartyLuo jihao, Manager, luojihao@mindray.com , 18927404012
Test FirmJoy Zhou, WALTEK TESTING GROUP CO., LTD., szqa@waltek.com.cn , 0769-22676998
TCB EmailTEI@timcoengr.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. This device supports 20 and 40 MHz modes.

Applications

Application IDDatePurpose
iEUSZevse9JjhimnsqhtAw==2024-09-17Original Equipment
QzhAnkvo3tdzsfYe5kHMOg==2024-09-17Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.270400015CCC
5180-5240 MHz0.2051215ECC
5745-5825 MHz0.2128115ECC

Grants

TCB Grant - Application QzhAnkvo3tdzsfYe5kHMOg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 09/17/2024

Application Dated: 09/17/2024
Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Mindray Building ,Keji 12th Road South,Hi-tech Ind
Shenzhen,
China
 
Attention: Luo jihao , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZLZ-MRR8860
Name of Grantee:  Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Wireless LAN Router
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.20512  
CC 15E 5745.0  -  5825.0 0.21281  

Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. This device supports 20, 40 and 80 MHz modes.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application QzhAnkvo3tdzsfYe5kHMOg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Mindray Building ,Keji 12th Road South,Hi-tech Ind
Shenzhen,
China
  Date of Grant: 09/17/2024

Application Dated: 09/17/2024
 
Attention: Luo jihao , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZLZ-MRR8860
Name of Grantee:  Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Wireless LAN Router
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.20512  
CC 15E 5745.0  -  5825.0 0.21281  

Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. This device supports 20, 40 and 80 MHz modes.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application iEUSZevse9JjhimnsqhtAw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 09/17/2024

Application Dated: 09/17/2024
Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Mindray Building ,Keji 12th Road South,Hi-tech Ind
Shenzhen,
China
 
Attention: Luo jihao , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZLZ-MRR8860
Name of Grantee:  Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Equipment Class: Digital Transmission System
Notes: Wireless LAN Router
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.2704  

Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. This device supports 20 and 40 MHz modes.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application iEUSZevse9JjhimnsqhtAw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Mindray Building ,Keji 12th Road South,Hi-tech Ind
Shenzhen,
China
  Date of Grant: 09/17/2024

Application Dated: 09/17/2024
 
Attention: Luo jihao , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZLZ-MRR8860
Name of Grantee:  Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Equipment Class: Digital Transmission System
Notes: Wireless LAN Router
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.2704  

Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. This device supports 20 and 40 MHz modes.