FCC ID ZLZ-TEARQ

Diagnostic Ultrasound System

by Shenzhen Mindray BIO-Medical electronics Co.,LTD.

Grantee Code: ZLZ   Product Code: TEARQ
Latest application date: 2024-08-21

FCC ID Device Details

FCC IDZLZ-TEARQ
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeZLZ
Product CodeTEARQ
Applicant BusinessShenzhen Mindray BIO-Medical electronics Co.,LTD. 🇨🇳
Related Domains mindray.com
Equipment ClassDiagnostic Ultrasound System
Test FirmShenzhen Huatongwei International Inspection Co.,

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5745-5825 MHzOriginal Equipment2024-08-21
2412-2462 MHzOriginal Equipment2024-08-21

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2024-08-21PDF 2.8 MB
Internal photosInternal Photos2024-08-21PDF 1.1 MB
External photosExternal Photos2024-08-21PDF 320.2 KB
LabelID Label/Location Info2024-08-21PDF 438.3 KB
Test setupTest Setup Photos2024-08-21PDF 309.7 KB
Antenna specificationTest Report2024-08-21PDF 2 MB
Modular test report BLE part 1Test Report2024-08-21PDF 1.2 MB
Modular test report BLE part 2Test Report2024-08-21PDF 5.6 MB
Modular test report WiFi part 1Test Report2024-08-21PDF 4.8 MB
Modular test report WiFi part 2Test Report2024-08-21PDF 3.2 MB
Modular test report WiFi part 3Test Report2024-08-21PDF 4.8 MB
Modular test report part 1Test Report2024-08-21PDF 551.5 KB
Modular test report part 2Test Report2024-08-21PDF 5.5 MB
Modular test report part 3Test Report2024-08-21PDF 5.8 MB
Modular test report part 4Test Report2024-08-21PDF 5.3 MB
Modular test report part 5Test Report2024-08-21PDF 2.3 MB
SAR test report part 1RF Exposure Info2024-08-21PDF 1.5 MB
SAR test report part 2RF Exposure Info2024-08-21PDF 38.7 KB
SAR test report part 3RF Exposure Info2024-08-21PDF 2.4 MB
SAR test report part 4RF Exposure Info2024-08-21PDF 2.7 MB
SAR test report part 5RF Exposure Info2024-08-21PDF 5.4 MB
Test reportTest Report2024-08-21PDF 787.5 KB
Test reportTest Report2024-08-21PDF 4.2 MB
Test report BLETest Report2024-08-21PDF 3.5 MB
Test report WiFiTest Report2024-08-21PDF 3.2 MB
Covered equipment list attestationAttestation Statements2024-08-21PDF 292.4 KB
US agent attestationAttestation Statements2024-08-21PDF 449.2 KB
Agent letterCover Letter(s)2024-08-21PDF 336.8 KB
Confidentiality request letterCover Letter(s)2024-08-21PDF 417.3 KB
Block Diagram Metadata onlyBlock DiagramPDF 180.4 KB
Schematics Metadata onlySchematicsPDF 1,011.6 KB
Operational Description Metadata onlyOperational DescriptionPDF 260 KB
Software Security Metadata onlySDR Software/Security Info.PDF 1.6 MB

Application Information

Application IDpov4eyt6Ga33B4v3cfCWwA==
Final Action Date2024-08-21
Application PurposeOriginal Equipment
Applicant FRN0020888061
ModelTEARQ
Frequency Range5745-5825 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionDiagnostic Ultrasound System
Responsible PartyLuo jihao, Manager, luojihao@mindray.com , 18927404012
Test FirmTony Jiang, Shenzhen Huatongwei International Inspection Co.,, tony.jiang@szhtw.com.cn , +86-755-26748078
TCB EmailTCB@nemko.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted. The highest reported SAR for body, simultaneous transmission, and extremity (hand) exposure conditions are 0.19 W/kg, 0.94 W/kg, and 1.12 W/kg, respectively.

Applications

Application IDDatePurpose
pov4eyt6Ga33B4v3cfCWwA==2024-08-21Original Equipment
p/oE+LUVNKYAGOhBoriA/Q==2024-08-21Original Equipment
fk7yp8YBEwqsQMdw6aJTGw==2024-08-21Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
15BCC
2402-2480 MHz0.00115CCC
2412-2462 MHz0.05515CCC
5180-5240 MHz0.04615ECC
5745-5825 MHz0.05215ECC

Grants

TCB Grant - Application pov4eyt6Ga33B4v3cfCWwA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, Inc.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 08/21/2024

Application Dated: 08/21/2024
Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Mindray Building ,Keji 12th Road South,Hi-tech Ind
Shenzhen,
China
 
Attention: Luo jihao , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZLZ-TEARQ
Name of Grantee:  Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Diagnostic Ultrasound System
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.046  
CC 15E 5745.0  -  5825.0 0.052  

Output power listed is conducted. The highest reported SAR for body, simultaneous transmission, and extremity (hand) exposure conditions are 0.19 W/kg, 0.94 W/kg, and 1.12 W/kg, respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application pov4eyt6Ga33B4v3cfCWwA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Mindray Building ,Keji 12th Road South,Hi-tech Ind
Shenzhen,
China
  Date of Grant: 08/21/2024

Application Dated: 08/21/2024
 
Attention: Luo jihao , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZLZ-TEARQ
Name of Grantee:  Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Diagnostic Ultrasound System
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.046  
CC 15E 5745.0  -  5825.0 0.052  

Output power listed is conducted. The highest reported SAR for body, simultaneous transmission, and extremity (hand) exposure conditions are 0.19 W/kg, 0.94 W/kg, and 1.12 W/kg, respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application p/oE+LUVNKYAGOhBoriA/Q==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, Inc.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 08/21/2024

Application Dated: 08/21/2024
Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Mindray Building ,Keji 12th Road South,Hi-tech Ind
Shenzhen,
China
 
Attention: Luo jihao , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZLZ-TEARQ
Name of Grantee:  Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Equipment Class: Digital Transmission System
Notes: Diagnostic Ultrasound System
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.055  
CC 15C 2402.0  -  2480.0 0.001  

Output power listed is conducted. The highest reported SAR for body, simultaneous transmission, and extremity (hand) exposure conditions are < 0.10 W/kg, 0.79 W/kg, and 0.27 W/kg, respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application p/oE+LUVNKYAGOhBoriA/Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Mindray Building ,Keji 12th Road South,Hi-tech Ind
Shenzhen,
China
  Date of Grant: 08/21/2024

Application Dated: 08/21/2024
 
Attention: Luo jihao , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZLZ-TEARQ
Name of Grantee:  Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Equipment Class: Digital Transmission System
Notes: Diagnostic Ultrasound System
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.055  
CC 15C 2402.0  -  2480.0 0.001  

Output power listed is conducted. The highest reported SAR for body, simultaneous transmission, and extremity (hand) exposure conditions are < 0.10 W/kg, 0.79 W/kg, and 0.27 W/kg, respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application fk7yp8YBEwqsQMdw6aJTGw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, Inc.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 08/21/2024

Application Dated: 08/21/2024
Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Mindray Building ,Keji 12th Road South,Hi-tech Ind
Shenzhen,
China
 
Attention: Luo jihao , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZLZ-TEARQ
Name of Grantee:  Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Equipment Class: Part 15 Class B Digital Device
Notes: Diagnostic Ultrasound System
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application fk7yp8YBEwqsQMdw6aJTGw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Mindray Building ,Keji 12th Road South,Hi-tech Ind
Shenzhen,
China
  Date of Grant: 08/21/2024

Application Dated: 08/21/2024
 
Attention: Luo jihao , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZLZ-TEARQ
Name of Grantee:  Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Equipment Class: Part 15 Class B Digital Device
Notes: Diagnostic Ultrasound System
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: