FCC ID ZLZ-TEARS
AirSight (Handheld mobile terminal)
by Shenzhen Mindray BIO-Medical electronics Co.,LTD.
Grantee Code: ZLZ Product Code: TEARS
Latest application date: 2024-09-24
FCC ID Device Details
| FCC ID | ZLZ-TEARS |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | ZLZ |
| Product Code | TEARS |
| Applicant Business | Shenzhen Mindray BIO-Medical electronics Co.,LTD. 🇨🇳 |
| Related Domains | |
| Equipment Class | AirSight (Handheld mobile terminal) |
| Test Firm | Shenzhen Morlab Communications Technology Co. Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2024-09-24 |
| 5955-6415 MHz | Original Equipment | 2024-09-24 |
| 5180-5240 MHz | Original Equipment | 2024-09-24 |
| 2402-2480 MHz | Original Equipment | 2024-09-24 |
| 13.56 MHz | Original Equipment | 2024-09-24 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2025-03-04 | PDF 478.6 KB |
| Internal_photo | Internal Photos | 2025-03-04 | PDF 3.1 MB |
| EXternal_photo | External Photos | 2025-03-04 | PDF 931.2 KB |
| Label | ID Label/Location Info | 2024-09-24 | PDF 406.4 KB |
| Test_Setup_Photos | Test Setup Photos | 2025-03-04 | PDF 719.5 KB |
| Test_Setup_Photos | Test Setup Photos | 2025-03-04 | PDF 743.2 KB |
| Test_Setup_Photos | Test Setup Photos | 2025-03-04 | PDF 705.8 KB |
| Test_Setup_Photos | Test Setup Photos | 2025-03-04 | PDF 849 KB |
| Test_Setup_Photos | Test Setup Photos | 2025-03-04 | PDF 746.2 KB |
| Test_Setup_Photos | Test Setup Photos | 2025-03-04 | PDF 433.9 KB |
| TsUp_SAR | Test Setup Photos | 2025-03-04 | PDF 458.8 KB |
| SZ24060156W05_WiFi6G_U-NII_4 Metadata only | Test Setup Photos | 2024-09-24 | PDF 5.4 MB |
| Antenna_Report | Test Report | 2024-09-24 | PDF 869.8 KB |
| SZ24060156E01_FCC_EMC | Test Report | 2024-09-24 | PDF 1.5 MB |
| SZ24060156W01_BLE_DTS | Test Report | 2024-09-24 | PDF 2.5 MB |
| SZ24060156W02_BTclassic_DSS | Test Report | 2024-09-24 | PDF 4.3 MB |
| SZ24060156W03_WiFi2.4G_DTS_1 | Test Report | 2024-09-24 | PDF 5.1 MB |
| SZ24060156W03_WiFi2.4G_DTS_2 | Test Report | 2024-09-24 | PDF 5.2 MB |
| SZ24060156W03_WiFi2.4G_DTS_3 | Test Report | 2024-09-24 | PDF 5.2 MB |
| SZ24060156W03_WiFi2.4G_DTS_4 | Test Report | 2024-09-24 | PDF 5.3 MB |
| SZ24060156W03_WiFi2.4G_DTS_5 | Test Report | 2024-09-24 | PDF 2.6 MB |
| SZ24060156W04_WiFi5G_U-NII_1 | Test Report | 2024-09-24 | PDF 5.2 MB |
| SZ24060156W04_WiFi5G_U-NII_2 | Test Report | 2024-09-24 | PDF 5.1 MB |
| SZ24060156W04_WiFi5G_U-NII_3 | Test Report | 2024-09-24 | PDF 5.3 MB |
| SZ24060156W04_WiFi5G_U-NII_4 | Test Report | 2024-09-24 | PDF 5.2 MB |
| SZ24060156W04_WiFi5G_U-NII_5 | Test Report | 2024-09-24 | PDF 5.1 MB |
| SZ24060156W04_WiFi5G_U-NII_6 | Test Report | 2024-09-24 | PDF 850 KB |
| SZ24060156W05_WiFi6G_U-NII_1 | Test Report | 2024-09-24 | PDF 5.5 MB |
| SZ24060156W05_WiFi6G_U-NII_2 | Test Report | 2024-09-24 | PDF 5.3 MB |
| SZ24060156W05_WiFi6G_U-NII_3 | Test Report | 2024-09-24 | PDF 5.3 MB |
| SZ24060156W05_WiFi6G_U-NII_4 | Test Report | 2024-09-24 | PDF 5.4 MB |
| SZ24060156W05_WiFi6G_U-NII_5 | Test Report | 2024-09-24 | PDF 5.3 MB |
| SZ24060156W05_WiFi6G_U-NII_6 | Test Report | 2024-09-24 | PDF 1.9 MB |
| SZ24060156W06_NFC_DXX | Test Report | 2024-09-24 | PDF 977.4 KB |
| Attestation_Statements_Part2.911(d)(5) | Attestation Statements | 2024-09-24 | PDF 126.3 KB |
| Attestation_Statements_Part2.911(d)(7) | Attestation Statements | 2024-09-24 | PDF 391.6 KB |
| FCC_Attestation_letter_6E | Attestation Statements | 2024-09-24 | PDF 313.8 KB |
| Confidentiality_Request_Letter | Cover Letter(s) | 2024-09-24 | PDF 386.2 KB |
| DTS_UNII_DeclarationLetter | Cover Letter(s) | 2024-09-24 | PDF 510.2 KB |
| POA | Cover Letter(s) | 2024-09-24 | PDF 331.6 KB |
| SAR_AnnexC | RF Exposure Info | 2024-09-24 | PDF 955.3 KB |
| SAR_AnnexD | RF Exposure Info | 2024-09-24 | PDF 2.3 MB |
| SAR_AnnexE | RF Exposure Info | 2024-09-24 | PDF 416.4 KB |
| SAR_AnnexF1 | RF Exposure Info | 2024-09-24 | PDF 3.7 MB |
| SAR_AnnexF10 | RF Exposure Info | 2024-09-24 | PDF 5.1 MB |
| SAR_AnnexF11 | RF Exposure Info | 2024-09-24 | PDF 1.9 MB |
| SAR_AnnexF12 | RF Exposure Info | 2024-09-24 | PDF 4.3 MB |
| SAR_AnnexF13 | RF Exposure Info | 2024-09-24 | PDF 5.4 MB |
| SAR_AnnexF13 Metadata only | RF Exposure Info | 2024-09-24 | |
| SAR_AnnexF14 | RF Exposure Info | 2024-09-24 | PDF 658.5 KB |
| SAR_AnnexF15 | RF Exposure Info | 2024-09-24 | PDF 1.7 MB |
| SAR_AnnexF16 | RF Exposure Info | 2024-09-24 | PDF 1.3 MB |
| SAR_AnnexF2 | RF Exposure Info | 2024-09-24 | PDF 5.2 MB |
| SAR_AnnexF3 | RF Exposure Info | 2024-09-24 | PDF 5.2 MB |
| SAR_AnnexF4 | RF Exposure Info | 2024-09-24 | PDF 4.3 MB |
| SAR_AnnexF5 Metadata only | RF Exposure Info | 2024-09-24 | |
| SAR_AnnexF5 | RF Exposure Info | 2024-09-24 | PDF 4.2 MB |
| SAR_AnnexF6 | RF Exposure Info | 2024-09-24 | PDF 2.2 MB |
| SAR_AnnexF7 | RF Exposure Info | 2024-09-24 | PDF 5.1 MB |
| SAR_AnnexF8 | RF Exposure Info | 2024-09-24 | PDF 5.5 MB |
| SAR_AnnexF9 | RF Exposure Info | 2024-09-24 | PDF 4.1 MB |
| SZ24060156S01_SAR_PD | RF Exposure Info | 2024-09-24 | PDF 2.7 MB |
| Block_Diagram Metadata only | Block Diagram | PDF 75.1 KB | |
| Schematic Metadata only | Schematics | PDF 910 KB | |
| Schematic-RF_module Metadata only | Schematics | PDF 607.5 KB | |
| Operational Description Metadata only | Operational Description | PDF 184.6 KB | |
| Software_Security_Info Metadata only | SDR Software/Security Info. | PDF 1.7 MB | |
| E-BOM Metadata only | Parts List/Tune Up Info | PDF 317.4 KB | |
| E-BOM-RF_module Metadata only | Parts List/Tune Up Info | PDF 56.5 KB |
Application Information
| Application ID | x2L4jNzUVP8tvdPrLM/dGA== |
|---|---|
| Final Action Date | 2024-09-24 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0020888061 |
| Model | TEARS |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | AirSight (Handheld mobile terminal) |
| Responsible Party | Luo jihao, Manager, luojihao@mindray.com |
| Test Firm | Mr. Su Feng, Shenzhen Morlab Communications Technology Co. Ltd., Zx.sun@morlab.cn |
| TCB Email | bentje.holger@phoenix-testlab.de |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 03/04/2025 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | Yes |
| Grant Comments | Output power is maximum peak conducted.This device has integrated DXX, DSS, DTS, NII and 6XD transmitters certified under the same FCC ID.SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn, hotspot and simultaneous transmission use conditions are 0.12 W/kg, 0.12 W/kg, 0.12 W/kg, and 0.31 W/kg, respectively. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| x2L4jNzUVP8tvdPrLM/dGA== | 2024-09-24 | Original Equipment |
| l8YiMNk2C5dqbGO+wEBcLA== | 2024-09-24 | Original Equipment |
| VP1cOsowxR7PA0qesMy59A== | 2024-09-24 | Original Equipment |
| MLk282Dr2Ndjss1MV/kX+A== | 2024-09-24 | Original Equipment |
| GQA1YUpObcd/9VBWhaJ99Q== | 2024-09-24 | Original Equipment |
| +OO7DhpchCXa/Wo7s+8GuQ== | 2024-09-24 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules | Grant Notes |
|---|---|---|---|
| 15B | CC | ||
| 13.56 MHz | 15C | CC | |
| 2402-2480 MHz | 0.0059800 | 15C | CC |
| 2402-2480 MHz | 0.01982 | 15C | CC |
| 2412-2472 MHz | 0.20774 | 15C | CC, MO |
| 2422-2462 MHz | 0.21583 | 15C | CC, MO |
| 5180-5240 MHz | 0.04194 | 15E | CC, MO |
| 5250-5320 MHz | 0.03987 | 15E | CC, MO |
| 5500-5720 MHz | 0.03504 | 15E | CC, MO |
| 5745-5825 MHz | 0.03197 | 15E | CC, MO |
| 5955-6415 MHz | 0.0078 | 15E | CC, EP, MO |
| 6435-6515 MHz | 0.0067 | 15E | CC, EP, MO |
| 6535-6855 MHz | 0.008 | 15E | CC, EP, MO |
| 6875-7115 MHz | 0.0078 | 15E | CC, EP, MO |
Grants
TCB Grant - Application x2L4jNzUVP8tvdPrLM/dGA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 09/24/2024 Application Dated: 09/04/2024 |
| Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Mindray Building ,Keji 12th Road South,Hi-tech Ind |
| Shenzhen, China |
| Attention: Luo jihao , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZLZ-TEARS |
| Name of Grantee: | Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | AirSight (Handheld mobile terminal) |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00598 |
| Output power is maximum peak conducted. This device has integrated DXX, DSS, DTS, NII and 6XD transmitters certified under the same FCC ID. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn, hotspot and simultaneous transmission use conditions are 0.12 W/kg, 0.12 W/kg, 0.12 W/kg, and 0.31 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application x2L4jNzUVP8tvdPrLM/dGA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shenzhen Mindray BIO-Medical electronics Co.,LTD. Mindray Building ,Keji 12th Road South,Hi-tech Ind Shenzhen, China |
Date of Grant: 09/24/2024 Application Dated: 09/04/2024 |
| Attention: Luo jihao , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZLZ-TEARS |
| Name of Grantee: | Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | AirSight (Handheld mobile terminal) |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00598 |
| Output power is maximum peak conducted. This device has integrated DXX, DSS, DTS, NII and 6XD transmitters certified under the same FCC ID. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn, hotspot and simultaneous transmission use conditions are 0.12 W/kg, 0.12 W/kg, 0.12 W/kg, and 0.31 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 09/24/2024 Application Dated: 09/04/2024 |
| Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Mindray Building ,Keji 12th Road South,Hi-tech Ind |
| Shenzhen, China |
| Attention: Luo jihao , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZLZ-TEARS |
| Name of Grantee: | Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | AirSight (Handheld mobile terminal) |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.04194 | ||
| CC MO | 15E | 5250.0 - 5320.0 | 0.03987 | ||
| CC MO | 15E | 5500.0 - 5720.0 | 0.03504 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.03197 |
| Output power is maximum average conducted. This device supports IEEE 802.11 a/n/ac/ax 20, 40, 80 and 160 MHz channel bandwidths. This device has integrated DXX, DSS, DTS, NII and 6XD transmitters certified under the same FCC ID. This device supports MIMO 2T2R. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. The highest reported SAR values for head, body-worn, hotspot and simultaneous transmission use conditions are 0.26 W/kg, 0.77 W/kg, 0.70 W/kg, and 0.84 W/kg, respectively. Product specific SAR at 10-gram tissue is 0.75 W/kg. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application VP1cOsowxR7PA0qesMy59A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shenzhen Mindray BIO-Medical electronics Co.,LTD. Mindray Building ,Keji 12th Road South,Hi-tech Ind Shenzhen, China |
Date of Grant: 09/24/2024 Application Dated: 09/04/2024 |
| Attention: Luo jihao , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZLZ-TEARS |
| Name of Grantee: | Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | AirSight (Handheld mobile terminal) |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.04194 | ||
| CC MO | 15E | 5250.0 - 5320.0 | 0.03987 | ||
| CC MO | 15E | 5500.0 - 5720.0 | 0.03504 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.03197 |
| Output power is maximum average conducted. This device supports IEEE 802.11 a/n/ac/ax 20, 40, 80 and 160 MHz channel bandwidths. This device has integrated DXX, DSS, DTS, NII and 6XD transmitters certified under the same FCC ID. This device supports MIMO 2T2R. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. The highest reported SAR values for head, body-worn, hotspot and simultaneous transmission use conditions are 0.26 W/kg, 0.77 W/kg, 0.70 W/kg, and 0.84 W/kg, respectively. Product specific SAR at 10-gram tissue is 0.75 W/kg. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 09/24/2024 Application Dated: 09/04/2024 |
| Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Mindray Building ,Keji 12th Road South,Hi-tech Ind |
| Shenzhen, China |
| Attention: Luo jihao , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZLZ-TEARS |
| Name of Grantee: | Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Equipment Class: | Digital Transmission System |
| Notes: | AirSight (Handheld mobile terminal) |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.01982 | ||
| CC MO | 15C | 2412.0 - 2472.0 | 0.20774 | ||
| CC MO | 15C | 2422.0 - 2462.0 | 0.21583 |
| Output power is maximum peak conducted. This device supports IEEE 802.11 b/g/n20/n40/ax20/ax40 MHz channel bandwidths. This device supports MIMO 2T2R. This device has integrated DXX, DSS, DTS, NII and 6XD transmitters certified under the same FCC ID. SAR compliance for body-worn operating configurations is limited to the belt- clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn, hotspot and simultaneous transmission use conditions are 0.14 W/kg, 0.16 W/kg, 0.16 W/kg, and 0.84 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application MLk282Dr2Ndjss1MV/kX+A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shenzhen Mindray BIO-Medical electronics Co.,LTD. Mindray Building ,Keji 12th Road South,Hi-tech Ind Shenzhen, China |
Date of Grant: 09/24/2024 Application Dated: 09/04/2024 |
| Attention: Luo jihao , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZLZ-TEARS |
| Name of Grantee: | Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Equipment Class: | Digital Transmission System |
| Notes: | AirSight (Handheld mobile terminal) |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.01982 | ||
| CC MO | 15C | 2412.0 - 2472.0 | 0.20774 | ||
| CC MO | 15C | 2422.0 - 2462.0 | 0.21583 |
| Output power is maximum peak conducted. This device supports IEEE 802.11 b/g/n20/n40/ax20/ax40 MHz channel bandwidths. This device supports MIMO 2T2R. This device has integrated DXX, DSS, DTS, NII and 6XD transmitters certified under the same FCC ID. SAR compliance for body-worn operating configurations is limited to the belt- clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values for head, body-worn, hotspot and simultaneous transmission use conditions are 0.14 W/kg, 0.16 W/kg, 0.16 W/kg, and 0.84 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 09/24/2024 Application Dated: 09/04/2024 |
| Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Mindray Building ,Keji 12th Road South,Hi-tech Ind |
| Shenzhen, China |
| Attention: Luo jihao , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZLZ-TEARS |
| Name of Grantee: | Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Equipment Class: | 15E 6 GHz Low Power Indoor Client |
| Notes: | AirSight (Handheld mobile terminal) |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC EP MO | 15E | 5955.0 - 6415.0 | 0.0078 | ||
| CC EP MO | 15E | 6435.0 - 6515.0 | 0.0067 | ||
| CC EP MO | 15E | 6535.0 - 6855.0 | 0.008 | ||
| CC EP MO | 15E | 6875.0 - 7115.0 | 0.0078 |
| Output power is maximum EIRP. This device supports IEEE 802.11 ax 20, 40, 80 and 160 MHz channel bandwidths. This device supports MIMO 2T2R. This device has integrated DXX, DSS, DTS, NII and 6XD transmitters certified under the same FCC ID. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. The highest reported power density is 0.33 mW/cm2. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application l8YiMNk2C5dqbGO+wEBcLA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shenzhen Mindray BIO-Medical electronics Co.,LTD. Mindray Building ,Keji 12th Road South,Hi-tech Ind Shenzhen, China |
Date of Grant: 09/24/2024 Application Dated: 09/04/2024 |
| Attention: Luo jihao , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZLZ-TEARS |
| Name of Grantee: | Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Equipment Class: | 15E 6 GHz Low Power Indoor Client |
| Notes: | AirSight (Handheld mobile terminal) |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC EP MO | 15E | 5955.0 - 6415.0 | 0.0078 | ||
| CC EP MO | 15E | 6435.0 - 6515.0 | 0.0067 | ||
| CC EP MO | 15E | 6535.0 - 6855.0 | 0.008 | ||
| CC EP MO | 15E | 6875.0 - 7115.0 | 0.0078 |
| Output power is maximum EIRP. This device supports IEEE 802.11 ax 20, 40, 80 and 160 MHz channel bandwidths. This device supports MIMO 2T2R. This device has integrated DXX, DSS, DTS, NII and 6XD transmitters certified under the same FCC ID. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the user's body. The highest reported power density is 0.33 mW/cm2. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 09/24/2024 Application Dated: 09/04/2024 |
| Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Mindray Building ,Keji 12th Road South,Hi-tech Ind |
| Shenzhen, China |
| Attention: Luo jihao , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZLZ-TEARS |
| Name of Grantee: | Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Equipment Class: | Part 15 Class B Computing Device/Personal Computer |
| Notes: | AirSight (Handheld mobile terminal) |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | - |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application GQA1YUpObcd/9VBWhaJ99Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shenzhen Mindray BIO-Medical electronics Co.,LTD. Mindray Building ,Keji 12th Road South,Hi-tech Ind Shenzhen, China |
Date of Grant: 09/24/2024 Application Dated: 09/04/2024 |
| Attention: Luo jihao , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZLZ-TEARS |
| Name of Grantee: | Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Equipment Class: | Part 15 Class B Computing Device/Personal Computer |
| Notes: | AirSight (Handheld mobile terminal) |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | - |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 09/24/2024 Application Dated: 09/04/2024 |
| Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Mindray Building ,Keji 12th Road South,Hi-tech Ind |
| Shenzhen, China |
| Attention: Luo jihao , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZLZ-TEARS |
| Name of Grantee: | Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Equipment Class: | Part 15 Low Power Communication Device Transmitter |
| Notes: | AirSight (Handheld mobile terminal) |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 13.56 - 13.56 |
| This device has integrated DXX, DSS, DTS, NII and 6XD transmitters certified under the same FCC ID. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application +OO7DhpchCXa/Wo7s+8GuQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shenzhen Mindray BIO-Medical electronics Co.,LTD. Mindray Building ,Keji 12th Road South,Hi-tech Ind Shenzhen, China |
Date of Grant: 09/24/2024 Application Dated: 09/04/2024 |
| Attention: Luo jihao , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZLZ-TEARS |
| Name of Grantee: | Shenzhen Mindray BIO-Medical electronics Co.,LTD. |
| Equipment Class: | Part 15 Low Power Communication Device Transmitter |
| Notes: | AirSight (Handheld mobile terminal) |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 13.56 - 13.56 |
| This device has integrated DXX, DSS, DTS, NII and 6XD transmitters certified under the same FCC ID. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |