FCC ID ZQR-LC120

CDMA1x 850MHz/1900MHz MPERs WRIST WATCH

by Lifecomm, LLC

Grantee Code: ZQR   Product Code: LC120
Latest application date: 2011-12-16

FCC ID Device Details

FCC IDZQR-LC120
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeZQR
Product CodeLC120
Applicant BusinessLifecomm, LLC 🇺🇸
Related Domains hughestelematics.com
Equipment ClassCDMA1x 850MHz/1900MHz MPERs WRIST WATCH
Test FirmCompliance Certification Services

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.7-848.31 MHzOriginal Equipment2011-12-16

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2012-06-03PDF 1.1 MB
InternalInternal Photos2012-06-03PDF 2.7 MB
ExternalExternal Photos2012-06-03PDF 1.1 MB
ID LabelID Label/Location Info2011-12-16PDF 47.7 KB
SAR Test Set-Up PhotosTest Setup Photos2012-06-03PDF 519.5 KB
Test Set-Up PhotosTest Setup Photos2012-06-03PDF 147.2 KB
Test report (Radiated)Test Report2011-12-16PDF 330.3 KB
Test report (conducted)Test Report2011-12-16PDF 1.3 MB
Agent AuthorizationCover Letter(s)2011-12-16PDF 67.1 KB
Authorization LetterCover Letter(s)2011-12-16PDF 19.8 KB
Confidentiality RequestCover Letter(s)2011-12-16PDF 43.3 KB
Cover LetterCover Letter(s)2011-12-16PDF 34 KB
SAR Report rev 2RF Exposure Info2011-12-16PDF 3.4 MB

Application Information

Application IDKbVG75/BLTgxlDlQSUrMHQ==
Final Action Date2011-12-16
Application PurposeOriginal Equipment
Applicant FRN0021002951
Model-LC120
Frequency Range824.7-848.31 MHz
Equipment ClassPCT - PCS Licensed Transmitter worn on body
Device DescriptionCDMA1x 850MHz/1900MHz MPERs WRIST WATCH
Responsible PartyAnne Marie Marx, Sr. Director, Program Launch, annemarie.marx@hughestelematics.com , 248-990-0498
AgentClaire Claire Claire, Compliance Certification Services, claire.hoque@ccsemc.com , (510) 771-1000
Technical ContactClaire Hoque, Compliance Certification Services, claire.hoque@ccsemc.com , (510)771-1000
Test FirmThu Chan, Compliance Certification Services, thu.chan@ccsemc.com , 510-771-1122
TCB Emailcertnotice@ccsemc.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date06/03/2012
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryYes
Grant CommentsOutput power is erp for Part 22H and eirp for part 24E. End-users must be provided with operating conditions for satisfying RF exposure compliance. The highest reported SAR values for head and extremity (wrist) use conditions are 0.67 W/kg and 3.05 W/kg, respectively.

Applications

Application IDDatePurpose
KbVG75/BLTgxlDlQSUrMHQ==2011-12-16Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.7-848.31 MHz0.19282.5ppm1M28F9W22H
1851.25-1908.75 MHz0.10622.5ppm1M28F9W24E

Grants

TCB Grant - Application KbVG75/BLTgxlDlQSUrMHQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc. (formerly UL CCS)
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 12/16/2011

Application Dated: 12/07/2011
Lifecomm, LLC
2002 Summit Blvd
Suite 1800
Atlanta, GA 30319
 
Attention: Anne Marie Marx , Sr. Director, Program Launch

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZQR-LC120
Name of Grantee:  Lifecomm, LLC
Equipment Class: PCS Licensed Transmitter worn on body
Notes: CDMA1x 850MHz/1900MHz MPERs WRIST WATCH
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.1928 2.5  PM 1M28F9W
24E 1851.25  -  1908.75 0.1062 2.5  PM 1M28F9W

Output power is erp for Part 22H and eirp for part 24E. End-users must be provided with operating conditions for satisfying RF exposure compliance. The highest reported SAR values for head and extremity (wrist) use conditions are 0.67 W/kg and 3.05 W/kg, respectively.

EAS Grant - Application KbVG75/BLTgxlDlQSUrMHQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Lifecomm, LLC
2002 Summit Blvd Suite 1800P.O. Box ,
Atlanta, GA 30319
United States
  Date of Grant: 12/16/2011

Application Dated: 12/07/2011
 
Attention: Anne Marie Marx , Sr. Director, Program Launch

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZQR-LC120
Name of Grantee:  Lifecomm, LLC
Equipment Class: PCS Licensed Transmitter worn on body
Notes: CDMA1x 850MHz/1900MHz MPERs WRIST WATCH
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.7  -  848.31 0.1928 2.5  PM 1M28F9W
24E 1851.25  -  1908.75 0.1062 2.5  PM 1M28F9W

Output power is erp for Part 22H and eirp for part 24E. End-users must be provided with operating conditions for satisfying RF exposure compliance. The highest reported SAR values for head and extremity (wrist) use conditions are 0.67 W/kg and 3.05 W/kg, respectively.