FCC ID ZRY5811BT-02

WIRELESS BLOOD PRESSURE MONITOR

by Andon Health Co., Ltd

Grantee Code: ZRY   Product Code: 5811BT02
Latest application date: 2026-06-28

FCC ID Device Details

FCC IDZRY5811BT-02
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeZRY
Product Code5811BT02
Applicant BusinessAndon Health Co., Ltd 🇨🇳
Related Domains jiuan.com ihealthlabs.com
Equipment ClassWIRELESS BLOOD PRESSURE MONITOR
Test FirmThe Hong Kong Standards and Testing Centre Limited

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2026-06-28

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2026-06-28PDF 1,017.7 KB
Internal PhotosInternal Photos2026-06-28PDF 1.1 MB
External PhotosExternal Photos2026-06-28PDF 1.2 MB
ID Label/Location InfoID Label/Location Info2026-06-28PDF 408.2 KB
Test Setup PhotosTest Setup Photos2026-06-28PDF 476.9 KB
ANT Test ReportTest Report2026-06-28PDF 570.6 KB
Test ReportTest Report2026-06-28PDF 2.9 MB
Attestation StatementsAttestation Statements2026-06-28PDF 226.5 KB
US agentAttestation Statements2026-06-28PDF 188.8 KB
Agent AuthorizationCover Letter(s)2026-06-28PDF 135 KB
Long term Confidentiality LetterCover Letter(s)2026-06-28PDF 152.1 KB
RF Exposure InfoRF Exposure Info2026-06-28PDF 107.9 KB
Block Diagram Metadata onlyBlock DiagramPDF 174.1 KB
Schematics Metadata onlySchematicsPDF 374.3 KB
Operational Description Metadata onlyOperational DescriptionPDF 60.2 KB

Application Information

Application ID6gk0uq535YAXNVEq/kcSUg==
Final Action Date2026-06-28
Application PurposeOriginal Equipment
Applicant FRN0021021365
Model5811BT-02
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionWIRELESS BLOOD PRESSURE MONITOR
Responsible PartyMing Cong, congming@jiuan.com , +86-22-60526161
Non-Technical ContactMing Cong, iHealth Labs, Inc., Ming.Cong@ihealthlabs.com , (855)816-7705
Test FirmBrian Chan, The Hong Kong Standards and Testing Centre Limited, brianchan@stc.group , +85226661880
TCB Emailtcb@metlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
6gk0uq535YAXNVEq/kcSUg==2026-06-28Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.00041515C

Grants

TCB Grant - Application 6gk0uq535YAXNVEq/kcSUg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Eurofins Electrical and Electronic Testing NA, Inc.
914 W. Patapsco Avenue
Baltimore, MD 21230-3432
Date of Grant: 06/28/2026

Application Dated: 06/29/2026
Andon Health Co., Ltd
No.3 JinPing Road, Nankai District
Tianjin, 300190
China
 
Attention: Ming Cong , PM

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  ZRY5811BT-02
Name of Grantee:  Andon Health Co., Ltd
Equipment Class: Digital Transmission System
Notes: WIRELESS BLOOD PRESSURE MONITOR
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.000415  

Output Power listed is conducted. This device has 1 MHz, 2 MHz, 20 MHz and 40 MHz bandwidth modes. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures.