FCC ID ZT3GMTALTO2
GSM Mobile Phone
by GoldGMT SA (Inc)
Grantee Code: ZT3 Product Code: GMTALTO2
Latest application date: 2011-09-17
FCC ID Device Details
| FCC ID | ZT3GMTALTO2 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | ZT3 |
| Product Code | GMTALTO2 |
| Applicant Business | GoldGMT SA (Inc) 🇨🇭 |
| Related Domains | |
| Equipment Class | GSM Mobile Phone |
| Test Firm | Bay Area Compliance Laboratory Corp. (Shenzhen) |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.2-848.8 MHz | Original Equipment | 2011-09-17 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2011-09-17 | PDF 3.7 MB |
| Internal Photos | Internal Photos | 2011-09-17 | PDF 600.5 KB |
| External Photos | External Photos | 2011-09-17 | PDF 361.4 KB |
| FCC ID Label Info | ID Label/Location Info | 2011-09-17 | PDF 86.3 KB |
| Test Setup Photos | Test Setup Photos | 2011-09-17 | PDF 282.9 KB |
| Test Report | Test Report | 2011-09-17 | PDF 473.4 KB |
| Confidentiality Request Letter | Cover Letter(s) | 2011-09-17 | PDF 872.6 KB |
| Product Similarity Declaration Letter | Cover Letter(s) | 2011-09-17 | PDF 49.2 KB |
| Parts List | Parts List/Tune Up Info | 2011-09-17 | PDF 74 KB |
| RF Exposure | RF Exposure Info | 2011-09-17 | PDF 3.2 MB |
Application Information
| Application ID | RuzjB9qxySu3mwVKiUMy3Q== |
|---|---|
| Final Action Date | 2011-09-17 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0021052410 |
| Model | GMTALTO2 |
| Frequency Range | 824.2-848.8 MHz |
| Equipment Class | PCE - PCS Licensed Transmitter held to ear |
| Device Description | GSM Mobile Phone |
| Responsible Party | Serge Claude Blaise Girardin, VP Marketing & Sales, serge.girardin@goldgmt.com |
| Test Firm | John Chan, Bay Area Compliance Laboratory Corp. (Shenzhen), john.chan@baclcorp.com |
| TCB Email | bacl.regulatory@baclcorp.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is ERP for Part 22H and EIRP for Part 24E. SAR compliance for Body-worn operations is restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device including its antenna and the user's body. End-users must be informed of the Body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are Head: 0.21 W/Kg, Body-worn: 0.51 W/Kg. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| RuzjB9qxySu3mwVKiUMy3Q== | 2011-09-17 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application RuzjB9qxySu3mwVKiUMy3Q==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratory Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 09/17/2011 Application Dated: 09/17/2011 |
| GoldGMT SA (Inc) |
| Rue Jaquet Droz 8 |
| Neuchatel, 2000 Switzerland |
| Attention: Serge Girardin , VP Marketing & Sales |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZT3GMTALTO2 |
| Name of Grantee: | GoldGMT SA (Inc) |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | GSM Mobile Phone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 1.549 | 2.5 PM | 250KGXW | |
| 24E | 1850.2 - 1909.8 | 0.438 | 2.5 PM | 250KGXW |
| Power listed is ERP for Part 22H and EIRP for Part 24E. SAR compliance for Body-worn operations is restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device including its antenna and the user's body. End-users must be informed of the Body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are Head: 0.21 W/Kg, Body-worn: 0.51 W/Kg. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations. |
EAS Grant - Application RuzjB9qxySu3mwVKiUMy3Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
GoldGMT SA (Inc) Rue Jaquet Droz 8 P.O. Box , Neuchatel, 2000 Switzerland |
Date of Grant: 09/17/2011 Application Dated: 09/17/2011 |
| Attention: Serge Girardin , VP Marketing & Sales |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZT3GMTALTO2 |
| Name of Grantee: | GoldGMT SA (Inc) |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | GSM Mobile Phone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 1.549 | 2.5 PM | 250KGXW | |
| 24E | 1850.2 - 1909.8 | 0.438 | 2.5 PM | 250KGXW |
| Power listed is ERP for Part 22H and EIRP for Part 24E. SAR compliance for Body-worn operations is restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device including its antenna and the user's body. End-users must be informed of the Body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR values are Head: 0.21 W/Kg, Body-worn: 0.51 W/Kg. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations. |