FCC ID ZZ6-AR5BXB112
802.11agn 3x3 MIMO PCIe Mini Card
by Varian Medical Systems, Inc. X-Ray Products
Grantee Code: ZZ6 Product Code: AR5BXB112
Latest application date: 2012-04-13
FCC ID Device Details
| FCC ID | ZZ6-AR5BXB112 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | ZZ6 |
| Product Code | AR5BXB112 |
| Applicant Business | Varian Medical Systems, Inc. X-Ray Products 🇺🇸 |
| Related Domains | |
| Equipment Class | 802.11agn 3x3 MIMO PCIe Mini Card |
| Test Firm | Compliance Certification Services |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Class II permissive change or modification of presently authorized equipment | 2012-04-13 |
| 5180-5240 MHz | Class II permissive change or modification of presently authorized equipment | 2012-04-13 |
| 5180-5240 MHz | Original Equipment | 2011-12-29 |
| 2412-2462 MHz | Original Equipment | 2011-12-29 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2012-06-26 | PDF 510.1 KB |
| internal photos | Internal Photos | 2012-10-09 | PDF 250.5 KB |
| Internal Photos | Internal Photos | 2012-06-26 | PDF 868.2 KB |
| SAR Report photos | External Photos | 2012-10-09 | PDF 822.3 KB |
| SAR photos | External Photos | 2012-10-09 | PDF 822.3 KB |
| external photos | External Photos | 2012-10-09 | PDF 902.3 KB |
| External Photos | External Photos | 2012-06-26 | PDF 688.5 KB |
| label and location | ID Label/Location Info | 2012-04-13 | PDF 36.6 KB |
| ID Label | ID Label/Location Info | 2011-12-29 | PDF 61.4 KB |
| operational description | Operational Description | 2012-04-13 | PDF 3.5 MB |
| SAR Report photos | Test Setup Photos | 2012-10-09 | PDF 822.3 KB |
| Test Setup Photos | Test Setup Photos | 2012-06-26 | PDF 352.1 KB |
| Test Setup Photos | Test Setup Photos | 2012-06-26 | PDF 353.8 KB |
| Test Report | Test Report | 2011-12-29 | PDF 3 MB |
| Test Report | Test Report | 2011-12-29 | PDF 3.7 MB |
| Authorization | Cover Letter(s) | 2012-04-13 | PDF 355.4 KB |
| CCS authorization | Cover Letter(s) | 2012-04-13 | PDF 355.4 KB |
| Confi Request new | Cover Letter(s) | 2012-04-13 | PDF 70.6 KB |
| PC2 Change Letter | Cover Letter(s) | 2012-04-13 | PDF 69.5 KB |
| PC2 Change letter | Cover Letter(s) | 2012-04-13 | PDF 69.5 KB |
| Cover Letters | Cover Letter(s) | 2011-12-29 | PDF 355.4 KB |
| Body SAR 2.4 | RF Exposure Info | 2012-04-13 | PDF 170.3 KB |
| Body SAR Test Plots 2.4 | RF Exposure Info | 2012-04-13 | PDF 170.3 KB |
| Body SAR test plots 5GHZ | RF Exposure Info | 2012-04-13 | PDF 523.7 KB |
| Body SAR test plots 5GHz | RF Exposure Info | 2012-04-13 | PDF 523.7 KB |
| Cal certificate DAE4 | RF Exposure Info | 2012-04-13 | PDF 473.2 KB |
| Head SAR 5 GHz | RF Exposure Info | 2012-04-13 | PDF 550.7 KB |
| Head SAR Test Plots2.4 | RF Exposure Info | 2012-04-13 | PDF 182.3 KB |
| Head SAR test plots 2.4 | RF Exposure Info | 2012-04-13 | PDF 182.3 KB |
| Head SAR test plots 5 GHz | RF Exposure Info | 2012-04-13 | PDF 550.7 KB |
| SAR Report no photos | RF Exposure Info | 2012-04-13 | PDF 4.5 MB |
| System Check Plots | RF Exposure Info | 2012-04-13 | PDF 584.6 KB |
| cal certificate e field probe | RF Exposure Info | 2012-04-13 | PDF 635.8 KB |
| cal certificate efield probe | RF Exposure Info | 2012-04-13 | PDF 635.8 KB |
| cal certificate validation dipole 2450 | RF Exposure Info | 2012-04-13 | PDF 595.1 KB |
| cal certificate validation dipole 2450V2 | RF Exposure Info | 2012-04-13 | PDF 595.1 KB |
| cal certificate validation dipole 5 GHZ | RF Exposure Info | 2012-04-13 | PDF 1.1 MB |
| cal certificate validation dipole 5GHz | RF Exposure Info | 2012-04-13 | PDF 1.1 MB |
| cal certification validation dipole 5GHz | RF Exposure Info | 2012-04-13 | PDF 1.1 MB |
| calibration certificate DAE4 | RF Exposure Info | 2012-04-13 | PDF 473.2 KB |
| MPE | RF Exposure Info | 2011-12-29 | PDF 799.4 KB |
Application Information
| Application ID | tCdN3+x1LMLcaZi1T2dQ+Q== |
|---|---|
| Final Action Date | 2012-04-13 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0024578569 |
| Model | -AR5BXB112 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | 802.11agn 3x3 MIMO PCIe Mini Card |
| Responsible Party | Afsaneh Rafati, afsaneh.rafati@varian.com |
| Test Firm | Thu Chan, Compliance Certification Services, thu.chan@ccsemc.com |
| TCB Email | certnotice@ccsemc.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 10/09/2012 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Single Modular Approval |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Class II Permissive Change to add a portable X-Ray Flat Panel Receptor configuration as described in this filing. Output power listed is conducted. Single Modular Approval for mobile RF Exposure conditions, Device is a 802.11 abgn Mini module operating in a 3Tx3R configuration as described in this filing. In Mobile RF Exposure configurations the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons. The antennas must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC Multi-transmitter product procedures. Approval is limited to OEM installation only. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. The highest reported SAR values for head and body are 0.18 W/kg and 0.23 W/kg, respectively. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| tCdN3+x1LMLcaZi1T2dQ+Q== | 2012-04-13 | Class II permissive change or modification of presently authorized equipment |
| aXO0h4ophxrx/28nNMYYOQ== | 2012-04-13 | Class II permissive change or modification of presently authorized equipment |
| mAdxhV4TUSzvsVlQypzTfg== | 2011-12-29 | Original Equipment |
| NW6ZjG7kR5JTk42zS1csAw== | 2011-12-29 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application tCdN3+x1LMLcaZi1T2dQ+Q==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 04/13/2012 Application Dated: 04/12/2012 |
| Varian Medical Systems, Inc. X-Ray Products |
| 1678 South Pioneer Road |
| Salt Lake City, UT 84104 |
| Attention: Afsaneh Rafati |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZZ6-AR5BXB112 |
| Name of Grantee: | Varian Medical Systems, Inc. X-Ray Products |
| Equipment Class: | Digital Transmission System |
| Notes: | 802.11agn 3x3 MIMO PCIe Mini Card |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.4539 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.3034 | ||
| CC | 15C | 2422.0 - 2452.0 | 0.1866 | ||
| CC | 15C | 5745.0 - 5825.0 | 0.2547 | ||
| CC | 15C | 5745.0 - 5825.0 | 0.3034 | ||
| CC | 15C | 5755.0 - 5795.0 | 0.1803 |
| Class II Permissive Change to add a portable X-Ray Flat Panel Receptor configuration as described in this filing. Output power listed is conducted. Single Modular Approval for mobile RF Exposure conditions, Device is a 802.11 abgn Mini module operating in a 3Tx3R configuration as described in this filing. In Mobile RF Exposure configurations the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons. The antennas must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC Multi-transmitter product procedures. Approval is limited to OEM installation only. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. The highest reported SAR values for head and body are 0.18 W/kg and 0.23 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application tCdN3+x1LMLcaZi1T2dQ+Q==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Varian Medical Systems, Inc. X-Ray Products 1678 South Pioneer Road Salt Lake City, UT 84104 United States |
Date of Grant: 04/13/2012 Application Dated: 04/12/2012 |
| Attention: Afsaneh Rafati |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZZ6-AR5BXB112 |
| Name of Grantee: | Varian Medical Systems, Inc. X-Ray Products |
| Equipment Class: | Digital Transmission System |
| Notes: | 802.11agn 3x3 MIMO PCIe Mini Card |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.4539 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.3034 | ||
| CC | 15C | 2422.0 - 2452.0 | 0.1866 | ||
| CC | 15C | 5745.0 - 5825.0 | 0.2547 | ||
| CC | 15C | 5745.0 - 5825.0 | 0.3034 | ||
| CC | 15C | 5755.0 - 5795.0 | 0.1803 |
| Class II Permissive Change to add a portable X-Ray Flat Panel Receptor configuration as described in this filing. Output power listed is conducted. Single Modular Approval for mobile RF Exposure conditions, Device is a 802.11 abgn Mini module operating in a 3Tx3R configuration as described in this filing. In Mobile RF Exposure configurations the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons. The antennas must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC Multi-transmitter product procedures. Approval is limited to OEM installation only. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. The highest reported SAR values for head and body are 0.18 W/kg and 0.23 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 12/29/2011 Application Dated: 12/29/2011 |
| Varian Medical Systems, Inc. X-Ray Products |
| 1678 South Pioneer Road |
| Salt Lake City, UT 84104 |
| Attention: Afsaneh Rafati |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZZ6-AR5BXB112 |
| Name of Grantee: | Varian Medical Systems, Inc. X-Ray Products |
| Equipment Class: | Digital Transmission System |
| Notes: | 802.11agn 3x3 MIMO PCIe Mini Card |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.4539 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.3034 | ||
| CC | 15C | 2422.0 - 2452.0 | 0.1866 | ||
| CC | 15C | 5745.0 - 5825.0 | 0.2547 | ||
| CC | 15C | 5745.0 - 5825.0 | 0.3034 | ||
| CC | 15C | 5755.0 - 5795.0 | 0.1803 |
| Output power listed is conducted. Single Modular Approval for mobile RF Exposure conditions, Device is a 802.11 abgn Mini module operating in a 3Tx3R configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Approval is limited to OEM installation only. OEM integrators must be provided with antenna installation instructions. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application NW6ZjG7kR5JTk42zS1csAw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Varian Medical Systems, Inc. X-Ray Products 1678 South Pioneer Road Salt Lake City, UT 84104 United States |
Date of Grant: 12/29/2011 Application Dated: 12/29/2011 |
| Attention: Afsaneh Rafati |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZZ6-AR5BXB112 |
| Name of Grantee: | Varian Medical Systems, Inc. X-Ray Products |
| Equipment Class: | Digital Transmission System |
| Notes: | 802.11agn 3x3 MIMO PCIe Mini Card |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.4539 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.3034 | ||
| CC | 15C | 2422.0 - 2452.0 | 0.1866 | ||
| CC | 15C | 5745.0 - 5825.0 | 0.2547 | ||
| CC | 15C | 5745.0 - 5825.0 | 0.3034 | ||
| CC | 15C | 5755.0 - 5795.0 | 0.1803 |
| Output power listed is conducted. Single Modular Approval for mobile RF Exposure conditions, Device is a 802.11 abgn Mini module operating in a 3Tx3R configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Approval is limited to OEM installation only. OEM integrators must be provided with antenna installation instructions. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 12/29/2011 Application Dated: 12/29/2011 |
| Varian Medical Systems, Inc. X-Ray Products |
| 1678 South Pioneer Road |
| Salt Lake City, UT 84104 |
| Attention: Afsaneh Rafati |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZZ6-AR5BXB112 |
| Name of Grantee: | Varian Medical Systems, Inc. X-Ray Products |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | 802.11agn 3x3 MIMO PCIe Mini Card |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0148 | ||
| CC | 15E | 5180.0 - 5240.0 | 0.0299 | ||
| CC | 15E | 5190.0 - 5230.0 | 0.05 |
| Output power listed is conducted. Single Modular Approval for mobile RF Exposure conditions, Device is a 802.11 abgn Mini module operating in a 3Tx3R configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Approval is limited to OEM installation only. OEM integrators must be provided with antenna installation instructions. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application mAdxhV4TUSzvsVlQypzTfg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Varian Medical Systems, Inc. X-Ray Products 1678 South Pioneer Road Salt Lake City, UT 84104 United States |
Date of Grant: 12/29/2011 Application Dated: 12/29/2011 |
| Attention: Afsaneh Rafati |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZZ6-AR5BXB112 |
| Name of Grantee: | Varian Medical Systems, Inc. X-Ray Products |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | 802.11agn 3x3 MIMO PCIe Mini Card |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0148 | ||
| CC | 15E | 5180.0 - 5240.0 | 0.0299 | ||
| CC | 15E | 5190.0 - 5230.0 | 0.05 |
| Output power listed is conducted. Single Modular Approval for mobile RF Exposure conditions, Device is a 802.11 abgn Mini module operating in a 3Tx3R configuration as described in this filing. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Approval is limited to OEM installation only. OEM integrators must be provided with antenna installation instructions. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
UL Verification Services Inc. (formerly UL CCS) 47173 Benicia Street Fremont, CA 94538 |
Date of Grant: 04/13/2012 Application Dated: 04/12/2012 |
| Varian Medical Systems, Inc. X-Ray Products |
| 1678 South Pioneer Road |
| Salt Lake City, UT 84104 |
| Attention: Afsaneh Rafati |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZZ6-AR5BXB112 |
| Name of Grantee: | Varian Medical Systems, Inc. X-Ray Products |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | 802.11agn 3x3 MIMO PCIe Mini Card |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0148 | ||
| CC | 15E | 5180.0 - 5240.0 | 0.0299 | ||
| CC | 15E | 5190.0 - 5230.0 | 0.05 |
| Class II Permissive Change to add a portable X-Ray Flat Panel Receptor configuration as described in this filing. . Output power listed is conducted. Single Modular Approval for mobile RF Exposure conditions, Device is a 802.11 abgn Mini module operating in a 3Tx3R configuration as described in this filing. The antennas must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC Multi-transmitter product procedures. Approval is limited to OEM installation only. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. The highest reported SAR values for head and body are 0.15 W/kg and 0.22 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application aXO0h4ophxrx/28nNMYYOQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Varian Medical Systems, Inc. X-Ray Products 1678 South Pioneer Road Salt Lake City, UT 84104 United States |
Date of Grant: 04/13/2012 Application Dated: 04/12/2012 |
| Attention: Afsaneh Rafati |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ZZ6-AR5BXB112 |
| Name of Grantee: | Varian Medical Systems, Inc. X-Ray Products |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | 802.11agn 3x3 MIMO PCIe Mini Card |
| Modular Type: | Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0148 | ||
| CC | 15E | 5180.0 - 5240.0 | 0.0299 | ||
| CC | 15E | 5190.0 - 5230.0 | 0.05 |
| Class II Permissive Change to add a portable X-Ray Flat Panel Receptor configuration as described in this filing. . Output power listed is conducted. Single Modular Approval for mobile RF Exposure conditions, Device is a 802.11 abgn Mini module operating in a 3Tx3R configuration as described in this filing. The antennas must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC Multi-transmitter product procedures. Approval is limited to OEM installation only. OEM integrators and end-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end user has no manual instructions to remove or install the device. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. Operations in the 5.15-5.25GHz band are restricted to indoor usage only. The highest reported SAR values for head and body are 0.15 W/kg and 0.22 W/kg, respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |