E2407 802.11 bgn + BT 2.1 (EDR) RF Exposure Info SAR Test Report Apple Inc.

Apple Inc. 802.11 bgn + BT 2.1 (EDR)

Alternate Views: Download [PDF]
FCC OET BULLETIN 65 SUPPLEMENT C
IC RSS-102 ISSUE 4
SAR EVALUATION REPORT
For
802.11 b/g/n + BT (2.1) EDR
MODEL: A1367
FCC ID: BCG-E2407
IC: 579C-E2407
REPORT NUMBER: 10U13294-16C
ISSUE DATE: August 27, 2010
Prepared for
APPLE INC
1 INFINITE LOOP, MS-26A
CUPERTINO, CA 95014
Prepared by
COMPLIANCE CERTIFICATION SERVICES
47173 BENICIA STREET
FREMONT, CA 94538, U.S.A.
TEL: (510) 771-1000
FAX: (510) 661-0888
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 2 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
Revision History
Rev. Issue Date Revisions Revised By
-- July 14, 2010 Initial Issue --
A August 19, 2010 Fixed some typos in the section 11.1 and 11.2 Devin Chang
B August 25, 2010 Updated EUT description. Devin Chang
C August 27, 2010 Updated report. Includes
1. Changed frequency range from 2412 -
2472 MHz to 2412 - 2462 MHz in the
section 1
2. Added all SAR plots into report includes
z-axis plot of the highest SAR
measurement. See section 13
Devin Chang
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 3 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
TABLE OF CONTENTS
1. ATTESTATION OF TEST RESULTS..................................................................................................4
2. TEST METHODOLOGY ......................................................................................................................5
3. FACILITIES AND ACCREDITATION..................................................................................................5
4. CALIBRATION AND UNCERTAINTY................................................................................................. 6
4.1. MEASURING INSTRUMENT CALIBRATION .............................................................................6
4.2. MEASUREMENT UNCERTAINTY.............................................................................................. 7
5. EQUIPMENT UNDER TEST ...............................................................................................................8
6. KDB 648474 SIMULTANEOUS TRANSMISSION CONSIDERATION...............................................8
7. SYSTEM SPECIFICATIONS ...............................................................................................................9
8. COMPOSITION OF INGREDIENTS FOR TISSUE SIMULATING LIQUIDS .................................... 10
9. LIQUID PARAMETERS CHECK.......................................................................................................11
9.1. LIQUID CHECK RESULTS FOR 2450 MHZ.............................................................................12
10. SYSTEM VERIFICATION .............................................................................................................13
10.1. SYSTEM CHECK RESULTS FOR D2450V2............................................................................13
11. OUTPUT POWER VERIFICATION............................................................................................... 16
11.1. WIFI RF OUTPUT POWER....................................................................................................... 16
11.2. BLUETOOTH RF OUTPUT POWER ........................................................................................16
12. SUMMARY OF TEST RESULTS..................................................................................................17
13. SAR TEST PLOTS........................................................................................................................18
14. ATTACHMENTS ...........................................................................................................................24
15. ANTENNA LOCATIONS...............................................................................................................25
16. TEST SETUP PHOTOS ................................................................................................................26
17. EXTERNAL PHOTOS...................................................................................................................28
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 4 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
1. ATTESTATION OF TEST RESULTS
Company name:
APPLE INC
1 INFINITE LOOP, MS-26A
CUPERTINO, CA 95014
EUT description: 802.11 b/g/n + BT (2.1) EDR
Model number: A1367
Serial number: CCQCV00JDCPC
Device category:: Portable
Exposure category: General Population/Uncontrolled Exposure
Date tested: July 8, 2010
FCC / IC rule parts Frequency Range [MHz] Highest 1-g SAR (mW/g) Limit (mW/g)
15.247 / RSS-102 2412 – 2462 Body: 1.11 (Face up) 1.6
Applicable Standards Test Results
FCC OET Bulletin 65 Supplement C 01-01
IC RSS 102 Issue 4 Pass
Compliance Certification Services, Inc. (CCS) tested the above equipment in accordance with the
requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions
expressed by CCS based on interpretations and/or observations of test results. Measurement
Uncertainties were not taken into account and are published for informational purposes only. The test
results show that the equipment tested is capable of demonstrating compliance with the requirements
as documented in this report.
Note: The results documented in this report apply only to the tested sample, under the conditions and
modes of operation as described herein. This document may not be altered or revised in any way
unless done so by CCS and all revisions are duly noted in the revisions section. Any alteration of this
document not carried out by CCS will constitute fraud and shall nullify the document. This report must
not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any
agency of the Federal Government, or any agency of any government (NIST Handbook 150, Annex A).
This report is written to support regulatory compliance of the applicable standards stated above.
Approved & Released For CCS By: Tested By:
SUNNY SHIH
ENGINEERING SUPERVISOR
COMPLIANCE CERTIFICATION SERVICES
DEVIN CHANG
EMC ENGINEER
COMPLIANCE CERTIFICATION SERVICES
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 5 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
2. TEST METHODOLOGY
The tests documented in this report were performed in accordance with FCC OET Bulletin 65
Supplement C 01-01, IC RSS 102 Issue 4 and the following specific FCC Test Procedures.
o KDB 648474 D01 SAR Handsets Multi Xmiter and Ant, v01r05
o KDB 248227 D01 SAR meas for 802 11abg v01r02
3. FACILITIES AND ACCREDITATION
The test sites and measurement facilities used to collect data are located at 47173 Benicia Street,
Fremont, California, USA.
CCS is accredited by NVLAP, Laboratory Code 200065-0. The full scope of accreditation can be viewed
at http://www.ccsemc.com.
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 6 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
4. CALIBRATION AND UNCERTAINTY
4.1. MEASURING INSTRUMENT CALIBRATION
The measuring equipment utilized to perform the tests documented in this report has been calibrated in
accordance with the manufacturer's recommendations, and is traceable to recognized national
standards.
MM DD Year
Robot - Six Axes Stäubli RX90BL N/A
Robot Remote Control Stäubli CS7MB 3403-91535
DASY4 Measurement Server SPEAG SEUMS001BA 1041
Probe Alignment Unit SPEAG LB (V2) 261
SAM Phantom (SAM1) SPEAG QD000P40CA 1185
SAM Phantom (SAM2) SPEAG QD000P40CA 1050
Oval Flat Phantom (ELI 4.0) SPEAG QD OVA001 B 1003
Electronic Pr obe kit HP 85070C N/A
S-Parameter Network Analyzer Agilent 8753ES-6 MY40001647 11 22 2010
Signal Generator Agilent 8753ES-6 MY40001647 11 22 2010
E-Field Probe SPEAG EX3DV4 3531 2 22 2011
Data Acquisition Electronics SPEAG DAE3 V1 500 9 15 2010
System Validation Dipole SPEAG D2450V2 706 4 18 2013
Amplifier Mini-Circuits ZVE-8G 90606
Amplifier Mini-Circuits ZHL-42W D072701-5
Simulating Liquid SPEAG H2450 N/A Within 24 hrs of first test
Simulating Liquid SPEAG M2450 N/A Within 24 hrs of first test
Cal. Due date
Name of Equipment Manufacturer Type/Model Serial No.
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Note: Per KDB 450824 D02 requirements for dipole calibration, CCS has adopted three years calibration intervals.
On annual basis, each measurement dipole has been evaluated and is in compliance with the following criteria:
1. There is no physical damage on the dipole
2. System validation with specific dipole is within 10% of calibrated value.
3. Return-loss is within 20% of calibrated measurement ( test data on file in CCS)
4. Impedance is within 5 of calibrated measurement (test data on file in CCS)
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 7 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
4.2. MEASUREMENT UNCERTAINTY
Component error, % Probe Distribution Divisor Sensitivity U (Xi), %
Measurement System
Probe Calibration (k=1) @ Body 2450 MHz 5.50 Normal 1 1 5.50
Axial Isotropy 1.15 Rectangula
r
1.732 0.7071 0.47
Hemispherical Isotropy 2.30 Rectangular 1.732 0.7071 0.94
Boundary Effect 0.90 Rectangular 1.732 1 0.52
Probe Linearity 3.45 Rectangula
r
1.732 1 1.99
System Detection Limits 1.00 Rectangular 1.732 1 0.58
Readout Electronics 0.30 Normal 1 1 0.30
Response Time 0.80 Rectangula
r
1.732 1 0.46
Integration Time 2.60 Rectangular 1.732 1 1.50
RF Ambient Conditions - Noise 3.00 Rectan
g
ula
r
1.732 1 1.73
RF Ambient Conditions - Reflections 3.00 Rectangula
r
1.732 1 1.73
Probe Positioner Mechanical Tolerance 0.40 Rectangular 1.732 1 0.23
Probe Positionin
g
with res
p
ect to Phantom 2.90 Rectan
g
ula
r
1.732 1 1.67
Extrapolation, Interpolation and Integration 1.00 Rectangula
r
1.732 1 0.58
Test Sample Related
Test Sam
p
le Positionin
g
2.90 Normal 1 1 2.90
Device Holder Uncertainty 3.60 Normal 1 1 3.60
Output Power Variation - SAR Drift 5.00 Rectangular 1.732 1 2.89
Phantom and Tissue Parameters
Phantom Uncertainty (shape and thickness) 4.00 Rectangula
r
1.732 1 2.31
Liquid Conductivity - deviation from target 5.00 Rectangular 1.732 0.64 1.85
Li
q
uid Conductivit
y
- measurement 2.43 Normal 1 0.64 1.56
Liquid Permittivity - deviation from target 5.00 Rectangula
r
1.732 0.6 1.73
Liquid Permittivity - measurement 0.02 Normal 1 0.6 0.01
9.57
Expanded Uncertainty U, Coverage Factor = 2, > 95 % Confidence = 19.14 %
Expanded Uncertainty U, Coverage Factor = 2, > 95 % Confidence = 1.52 dB
Measurement uncertainty for 300 MHz to 3 GHz averaged over 1 gram
Combined Standard Uncertainty Uc(y) =
Measurement uncertainty for 300 MHz to 3 GHz averaged over 10 gram
Component error, % Probe Distribution Divisor Sensitivity U (Xi), %
Measurement System
Probe Calibration (k=1) @ Body 2450 MHz 5.50 Normal 1 1 5.50
Axial Isotropy 1.15 Rectangular 1.73
2
0.7071 0.47
Hemispherical Isotropy 2.30 Rectangular 1.732 0.7071 0.94
Boundary Effect 0.90 Rectangular 1.732 1 0.52
Probe Linearity 3.45 Rectangular 1.73
2
11.99
System Detection Limits 1.00 Rectangular 1.732 1 0.58
Readout Electronics 0.30 Normal 1 1 0.30
Response Time 0.80 Rectangular 1.73
2
10.46
Integration Time 2.60 Rectangular 1.732 1 1.50
RF Ambient Conditions - Noise 3.00 Rectan
ular 1.73
2
11.73
RF Ambient Conditions - Reflections 3.00 Rectangular 1.73
2
11.73
Probe Positioner Mechanical Tolerance 0.40 Rectangular 1.732 1 0.23
Probe Positionin
g
with res
p
ect to Phantom 2.90 Rectan
ular 1.73
2
11.67
Extrapolation, Interpolation and Integration 1.00 Rectangular 1.73
2
10.58
Test Sample Related
Test Sam
p
le Positionin
g
2.90 Normal 1 1 2.90
Device Holder Uncertainty 3.60 Normal 1 1 3.60
Output Power Variation - SAR Drift 5.00 Rectangular 1.732 1 2.89
Phantom and Tissue Parameters
Phantom Uncertainty (shape and thickness) 4.00 Rectangular 1.73
2
12.31
Liquid Conductivity - deviation from target 5.00 Rectangular 1.732 0.43 1.24
Li
q
uid Conductivit
y
- measurement 2.43 Normal 1 0.43 1.04
Liquid Permittivity - deviation from target 5.00 Rectangular 1.73
2
0.49 1.41
Liquid Permittivity - measurement uncertainty 0.02 Normal 1 0.49 0.01
9.35
Expanded Uncertainty U, Coverage Factor = 2, > 95 % Confidence = 18.69 %
Expanded Uncertainty U, Coverage Factor = 2, > 95 % Confidence = 1.49 dB
Combined Standard Uncertainty Uc(y), % =
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 8 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
5. EQUIPMENT UNDER TEST
The Apple Model Number A1367 is an iPod Touch product. This is a 802.11 b/g/n + BT (2.1) EDR. The
A1367 measures 110.8 mm (4.362 inches) long x 58.9 mm (2.318 inches) wide x 7.2 mm (0.283 inches)
thick and weighs 99.2 grams (3.5 oz.). The rechargeable battery is not user accessible.
The Apple A1367 comes with one of three memory configurations, 8 / 16 / 32 / 64 Giga Bytes for storing
music, video or data. The Apple A1367 function is fully compatible with Apple’s iTunes software. The
Apple A1367 in box materials include; Apple ear buds (no microphone), and 30 pin to USB cable.
Normal operation: Hand-held, or
Worn on body (LCD facing-up; LCD facing-down) with 0 mm separation
distance from EUT to body.
Body Worn Accessory Headset
Antenna-to-antenna
separation distances:
0 cm - WiFi (802.11g)-to-Bluetooth antenna
(WiFi-to-Bluetooth are sharing a common antenna)
Simultaneous transmission: WiFi can not transmit simultaneously with Bluetooth
6. KDB 648474 SIMULTANEOUS TRANSMISSION CONSIDERATION
SUMMARY OF SAR EVALUATION FOR A DEVUCE WITH MULTIPLE TRANSMITTERS
Individual Transmitter Stand-alone SAR
WiFi Yes
Bluetooth Stan-alone SAR not required due to the output 60/f
SIMULTANEOUS TRANSMISSION
WiFi can not transmit simultaneously with Bluetooth
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 9 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
7. SYSTEM SPECIFICATIONS
The DASY4 system for performing compliance tests consists of the following items:
A standard high precision 6-axis robot (Stäubli RX family) with controller, teach pendant and
software. An arm extension for accommodating the data acquisition electronics (DAE).
A dosimetric probe, i.e., an isotropic E-field probe optimized and calibrated for usage in tissue
simulating liquid. The probe is equipped with an optical surface detector system.
A data acquisition electronics (DAE) which performs the signal amplification, signal multiplexing,
AD-conversion, offset measurements, mechanical surface detection, collision detection, etc. The
unit is battery powered with standard or rechargeable batteries. The signal is optically transmitted
to the EOC.
The function of the measurement server is to perform the time critical tasks such as signal
filtering, control of the robot operation and fast movement interrupts.
A probe alignment unit which improves the (absolute) accuracy of the probe positioning.
A computer operating Windows 2000 or Windows XP.
DASY4 software.
Remote controls with teach pendant and additional circuitry for robot safety such as warning
lamps, etc.
The SAM twin phantom enabling testing left-hand and right-hand usage.
The device holder for handheld mobile phones.
Tissue simulating liquid mixed according to the given recipes.
Validation dipole kits allowing validating the proper functioning of the system.
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 10 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
8. COMPOSITION OF INGREDIENTS FOR TISSUE SIMULATING LIQUIDS
The following tissue formulations are provided for reference only as some of the parameters have not
been thoroughly verified. The composition of ingredients may be modified accordingly to achieve the
desired target tissue parameters required for routine SAR evaluation.
Frequency (MHz)
Ingredients
(% by weight) 450 835 900 1800 - 1900 2450
Tissue Type Head Body Head Body Head Body Head Body Head Body
Water 38.56 51.16 41.45 52.4 41.05 56.0 54.9 40.4 62.7 73.2
Salt (NaCl) 3.95 1.49 1.45 1.4 1.35 0.76 0.18 0.5 0.5 0.04
Sugar 56.32 46.78 56.0 45.0 56.5 41.76 0.0 58.0 0.0 0.0
HEC 0.98 0.52 1.0 1.0 1.0 1.21 0.0 1.0 0.0 0.0
Bactericide 0.19 0.05 0.1 0.1 0.1 0.27 0.0 0.1 0.0 0.0
Triton X-100 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 36.8 0.0
DGBE 0.0 0.0 0.0 0.0 0.0 0.0 44.92 0.0 0.0 26.7
Dielectric Constant 43.42 58.0 42.54 56.1 42.0 56.8 39.9 54.0 39.8 52.5
Conductivity (S/m) 0.85 0.83 0.91 0.95 1.0 1.07 1.42 1.45 1.88 1.78
Salt: 99+% Pure Sodium Chloride Sugar: 98+% Pure Sucrose
Water: De-ionized, 16 M+ resistivity HEC: Hydroxyethyl Cellulose
DGBE: 99+% Di(ethylene glycol) butyl ether, [2-(2-butoxyethoxy)ethanol]
Triton X-100 (ultra pure): Polyethylene glycol mono [4-(1,1, 3, 3-tetramethylbutyl)phenyl]ether
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 11 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
9. LIQUID PARAMETERS CHECK
The simulating liquids should be checked at the beginning of a series of SAR measurements to
determine of the dielectric parameters are within the tolerances of the specified target values. For
frequencies in 300 MHz to just under 2 GHz, the measured conductivity and relative permittivity should
be within ± 5% of the target values. For frequencies in the range of 2–3 GHz and above the measured
conductivity should be within ± 5% of the target values. The measured relative permittivity tolerance can
be relaxed to no more than ± 10%.
Reference Values of Tissue Dielectric Parameters for Head and Body Phantom
The head tissue dielectric parameters recommended by the IEEE SCC-34/SC-2 in IEEE Standard 1528
have been incorporated in the following table. These head parameters are derived from planar layer
models simulating the highest expected SAR for the dielectric properties and tissue thickness variations
in a human head. Other head and body tissue parameters that have not been specified in P1528 are
derived from the tissue dielectric parameters computed from the 4-Cole-Cole equations and extrapolated
according to the head parameters specified in IEEE Standard 1528.
ε
r
σ (S/m) ε
r
σ (S/m)
150 52.3 0.76 61.9 0.8
300 45.3 0.87 58.2 0.92
450 43.5 0.87 56.7 0.94
835 41.5 0.9 55.2 0.97
900 41.5 0.97 55 1.05
915 41.5 0.98 55 1.06
1450 40.5 1.2 54 1.3
1610 40.3 1.29 53.8 1.4
1800 – 2000 40 1.4 53.3 1.52
2450 39.2 1.8 52.7 1.95
3000 38.5 2.4 52 2.73
5800 35.3 5.27 48.2 6
Target Frequency (MHz) Head Body
(εr = relative permittivity, σ = conductivity and ρ = 1000 kg/m3)
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 12 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
9.1. LIQUID CHECK RESULTS FOR 2450 MHZ
Simulating Liquid Dielectric Parameters for Body 2450 MHz
Room Ambient Temperature = 24°C; Relative humidity = 41% Measured by: Devin Chang
f (MHz) Measured Target Delta (%) Limit (%)
e' 52.71 Relative Permittivity (єr): 52.712 52.7 0.02 ± 5
e" 14.65 Conductivity (σ): 1.997 1.95 2.43 ± 5
2450
Liquid Parameters
Liquid Check
Ambient temperature: 24 deg. C; Liquid temperature: 23 deg. C
July 08, 2010 09:38 AM
Frequency e' e''
2400000000. 52.9076 14.4447
2405000000. 52.8767 14.4579
2410000000. 52.8600 14.4928
2415000000. 52.8378 14.4977
2420000000. 52.8254 14.5293
2425000000. 52.7897 14.5511
2430000000. 52.7745 14.5742
2435000000. 52.7635 14.5874
2440000000. 52.7576 14.6116
2445000000. 52.7330 14.6371
2450000000. 52.7119 14.6546
2455000000. 52.6810 14.6632
2460000000. 52.6841 14.6901
2465000000. 52.6591 14.7191
2470000000. 52.6357 14.7393
2475000000. 52.6271 14.7516
2480000000. 52.6000 14.7768
2485000000. 52.5884 14.8034
2490000000. 52.5697 14.8202
2495000000. 52.5494 14.8474
2500000000. 52.5235 14.8722
The conductivity (σ) can be given as:
σ = ωε0 e''= 2 π f ε0 e''
where f = target f * 106
ε0 = 8.854 * 10-12
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 13 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
10. SYSTEM VERIFICATION
The system performance check is performed prior to any usage of the system in order to verify SAR
system measurement accuracy. The system performance check verifies that the system operates within
its specifications of ±10%.
System Performance Check Measurement Conditions
The measurements were performed in the flat section of the SAM twin phantom filled with Head or
Body simulating liquid of the following parameters.
The DASY4 system with an Isotropic E-Field Probe EX3DV3 was used for the measurements.
The dipole was mounted on the small tripod so that the dipole feed point was positioned below the
center marking of the flat phantom section and the dipole was oriented parallel to the body axis (the
long side of the phantom). The standard measuring distance was 10 mm (above 1 GHz) and
15 mm (below 1 GHz) from dipole center to the simulating liquid surface.
The coarse grid with a grid spacing of 15 mm was aligned with the dipole.
For 5 GHz band - The coarse grid with a grid spacing of 10 mm was aligned with the dipole.
Special 7x7x7 fine cube was chosen for cube
Distance between probe sensors and phantom surface was set to 3 mm.
For 5 GHz band - Distance between probe sensors and phantom surface was set to 2.5 mm
The dipole input power (forward power) was 100 mW
The results are normalized to 1 W input power.
Reference SAR Values for HEAD & BODY-tissue from calibration certificate of SPEAG.
Tissue: Head Body
SAR
1g
:51.6 52.4
SAR
10g
:24.4 24.5
System
validation dipole
Cal.
due date
Cal. certificate # SAR Avg (mW/g)
D2450V2 D2450V2-706_Apr10 4/18/13
10.1. SYSTEM CHECK RESULTS FOR D2450V2
Ambient Temperature = 24°C; Relative humidity = 41% Measured by: Devin Chang
Tissue: Body
SAR
1g
: 51.7 52.4 -1.34
SAR
10g
: 24.2 24.5 -1.22
System
validation dipole
Measured (Normalized to 1 W)
Date Tested
±10
Delta (%) Tolerance
(%)
D2450V2 07/08/10
Target
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 14 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
SYSTEM CHECK PLOT
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 15 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
SYSTEM CHECK – Z Plot
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 16 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
11. OUTPUT POWER VERIFICATION
11.1. WIFI RF OUTPUT POWER
(dBm) (mW )
12412 16.8 47.9
62437 16.9 48.8
11 2462 16.8 47.9
12412 14.6 28.8
62437 16.7 46.8
11 2462 14.6 28.8
12412 13.8 24.0
62437 16.6 45.7
11 2462 13.7 23.4
802.11b
802.11g
802.11n HT20
Conducted Avg Power
Freq. (MHz)Channel #
Note: KDB 248227 - SAR is not required for 802.11g/HT20 channels when the maximum average output
power is less than 1/4 dB higher than that measured on the corresponding 802.11b channels.
11.2. BLUETOOTH RF OUTPUT POWER
(dBm) (mW)
02402 10.7 11.7
39 2441 11.2 13.2
78 2480 11.5 14.1
02402 10.0 10.0
39 2441 10.2 10.5
78 2480 10.2 10.5
02402 7.9 6.2
39 2441 8.2 6.6
78 2480 8.1 6.5
Bluetooth
Channel #
GFSK
QPSK
8PSK
Conducted Avg Power
Freq. (MHz)Mode
Note: According to KDB 648474, Table 2, Unlicensed transmitters
When there is no simultaneous transmission – (WiFi can not transmit simultaneously with Bluetooth)
Output 60/f (25 mW): SAR is not required
Output > 60/f (25 mW): stand-alone SAR required
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 17 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
12. SUMMARY OF TEST RESULTS
Body SAR with 0 cm separation distance
1-g 10-g
1 2412 1.110 0.351
6 2437 1.110 0.349
11 2462 1.010 0.314
w/ headset 6 2437 1.090 0.339
1 2412
6 2437 0.293 0.126
11 2462
Band Test
position
SAR (mW/g)
Freq.
(MHz)
Ch No.Mode
Face up
Face down
2.4 GHz 802.11b
Note: KDB 248227 - SAR is not required for 802.11g/HT20 channels when the maximum average output power is
less than 1/4 dB higher than that measured on the corresponding 802.11b channels
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 18 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
13. SAR TEST PLOTS
BODY SAR plot
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 19 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
Worst-case BODY SAR plot
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 20 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
Worst-case BODY Z-axis
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 21 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
BODY SAR plot
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 22 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
BODY SAR plot
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 23 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
BODY SAR plot
REPORT NO: 10U13294-16C DATE: August 27, 2010
FCC ID: BCG-E2407 IC: 579C-E2407
Page 24 of 28
COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888
This report shall not be reproduced except in full, without the written approval of CCS.
14. ATTACHMENTS
No. Contents No. of page (s)
1 Certificate of E-Field Probe - EX3DV3 SN 3531 11
2 Certificate of System Validation Dipole - D2450 SN:706 9
Download: E2407 802.11 bgn + BT 2.1 (EDR) RF Exposure Info SAR Test Report Apple Inc.
Mirror Download [FCC.gov]E2407 802.11 bgn + BT 2.1 (EDR) RF Exposure Info SAR Test Report Apple Inc.
Document ID1336224
Application ID2KRVHx8WG9q7PSRLYuOxxg==
Document DescriptionSAR Test Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize54.81kB (685115 bits)
Date Submitted2010-09-01 00:00:00
Date Available2010-09-01 00:00:00
Creation Date2010-08-27 18:49:46
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2010-08-27 17:11:37
Document TitleSAR Test Report
Document CreatorPScript5.dll Version 5.2
Document Author: dchang