FCC ID EO9CCU100T
AMR transceiver device for reading utility meter
by Itron, Inc.
Grantee Code: EO9 Product Code: CCU100T
Latest application date: 2013-06-13
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 903-926.9 MHz | Class II permissive change or modification of presently authorized equipment | 2013-06-13 |
| 2412-2462 MHz | Original Equipment | 2010-10-29 |
| 903-926.8 MHz | Original Equipment | 2010-10-29 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Users Manual | Users Manual | 2010-10-29 | PDF 2.4 MB |
| Internal Photos 1 | Internal Photos | 2010-10-29 | PDF 5.4 MB |
| Internal Photos 2 | Internal Photos | 2010-10-29 | PDF 4.3 MB |
| External Photos | External Photos | 2010-10-29 | PDF 2.8 MB |
| ID Label | ID Label/Location Info | 2010-10-29 | PDF 73.5 KB |
| Label Location | ID Label/Location Info | 2010-10-29 | PDF 46.5 KB |
| Test Setup Photos | Test Setup Photos | 2010-10-29 | PDF 122.2 KB |
| Test Setup Photos | Test Setup Photos | 2010-10-29 | PDF 152.1 KB |
| Test Report 1 | Test Report | 2013-06-13 | PDF 1.3 MB |
| Test Report 2 | Test Report | 2013-06-13 | PDF 1,015.3 KB |
| Test Report Part 1 | Test Report | 2010-10-29 | PDF 4.3 MB |
| Test Report Part 1 | Test Report | 2010-10-29 | PDF 4.7 MB |
| Test Report Part 2 | Test Report | 2010-10-29 | PDF 3.5 MB |
| Test Report Part 2 | Test Report | 2010-10-29 | PDF 2.8 MB |
| Confidentiality Letter | Cover Letter(s) | 2013-06-13 | PDF 71.1 KB |
| Cover Letter | Cover Letter(s) | 2013-06-13 | PDF 68.7 KB |
| Confidentiality Letter | Cover Letter(s) | 2010-10-29 | PDF 301.3 KB |
| Confidentiality Request | Cover Letter(s) | 2010-10-29 | PDF 301.3 KB |
| Cover Letter | Cover Letter(s) | 2010-10-29 | PDF 232.3 KB |
| TCB Correspondence | Cover Letter(s) | 2010-10-29 | PDF 34.9 KB |
| RF Exposure | RF Exposure Info | 2013-06-13 | PDF 123.8 KB |
| MPE Report | RF Exposure Info | 2010-10-29 | PDF 101.4 KB |
| MPE report | RF Exposure Info | 2010-10-29 | PDF 101.4 KB |
Application Information
| Application ID | NL7pTiob0W/Z48jKuOEkOQ== |
|---|---|
| Final Action Date | 2013-06-13 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0005861034 |
| Model | CCU100T |
| Frequency Range | 903-926.9 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | AMR transceiver device for reading utility meter |
| Responsible Party | Jay R. Holcomb, R&D; Manager, Regulatory and Programs, jay.holcomb@itron.com |
| Technical Contact | Jay R. Holcomb, Itron, Inc., jay.holcomb@itron.com |
| Test Firm | Steve Behm, CKC Laboratories, Inc., steve.behm@ckc.com |
| TCB Email | info@ckccertification.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | C2PC for operational characteristics. Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter procedures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| NL7pTiob0W/Z48jKuOEkOQ== | 2013-06-13 | Class II permissive change or modification of presently authorized equipment |
| t0IqyM2DyA8MKjYVD+Tmjg== | 2010-10-29 | Original Equipment |
| ZICPBU2/4l8KcUQyH+y/lg== | 2010-10-29 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application ZICPBU2/4l8KcUQyH+y/lg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CKC Certification Services, LLC 5046 Sierra Pines Mariposa, CA 95338 |
Date of Grant: 10/29/2010 Application Dated: 10/29/2010 |
| Itron, Inc. |
| 2111 N. Molter Road |
| Liberty Lake, WA 99019 |
| Attention: Jay Holcomb , R&D Manager, Regulatory and Programs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EO9CCU100T |
| Name of Grantee: | Itron, Inc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | AMR transceiver device reading AMR endpoints |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 20 | 15C | 903.0 - 926.8 | 0.603 |
| Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| 20: | All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed. |
EAS Grant - Application ZICPBU2/4l8KcUQyH+y/lg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Itron, Inc. 2111 N. Molter Road Liberty Lake, WA 99019 United States |
Date of Grant: 10/29/2010 Application Dated: 10/29/2010 |
| Attention: Jay Holcomb , R&D Manager, Regulatory and Programs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EO9CCU100T |
| Name of Grantee: | Itron, Inc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | AMR transceiver device reading AMR endpoints |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 20 | 15C | 903.0 - 926.8 | 0.603 |
| Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| 20: | All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CKC Certification Services, LLC 5046 Sierra Pines Mariposa, CA 95338 |
Date of Grant: 10/29/2010 Application Dated: 10/29/2010 |
| Itron, Inc. |
| 2111 N. Molter Road |
| Liberty Lake, WA 99019 |
| Attention: Jay Holcomb , R&D Manager, Regulatory and Programs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EO9CCU100T |
| Name of Grantee: | Itron, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | AMR transceiver device reading AMR endpoints |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 20 | 15C | 2412.0 - 2462.0 | 0.044 |
| Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| 20: | All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed. |
EAS Grant - Application t0IqyM2DyA8MKjYVD+Tmjg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Itron, Inc. 2111 N. Molter Road Liberty Lake, WA 99019 United States |
Date of Grant: 10/29/2010 Application Dated: 10/29/2010 |
| Attention: Jay Holcomb , R&D Manager, Regulatory and Programs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EO9CCU100T |
| Name of Grantee: | Itron, Inc. |
| Equipment Class: | Digital Transmission System |
| Notes: | AMR transceiver device reading AMR endpoints |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 20 | 15C | 2412.0 - 2462.0 | 0.044 |
| Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. |
| 20: | All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
CKC Certification Services, LLC 5046 Sierra Pines Mariposa, CA 95338 |
Date of Grant: 06/13/2013 Application Dated: 06/05/2013 |
| Itron, Inc. |
| 2111 N. Molter Road |
| Liberty Lake, WA 99019 |
| Attention: Jay Holcomb , R&D Manager, Regulatory and Programs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EO9CCU100T |
| Name of Grantee: | Itron, Inc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | AMR transceiver device for reading utility meter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 20 | 15C | 903.0 - 926.9 | 0.603 |
| C2PC for operational characteristics. Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter procedures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing. |
| 20: | All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed. |
EAS Grant - Application NL7pTiob0W/Z48jKuOEkOQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Itron, Inc. 2111 N. Molter Road Liberty Lake, WA 99019 United States |
Date of Grant: 06/13/2013 Application Dated: 06/05/2013 |
| Attention: Jay Holcomb , R&D Manager, Regulatory and Programs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | EO9CCU100T |
| Name of Grantee: | Itron, Inc. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | AMR transceiver device for reading utility meter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 20 | 15C | 903.0 - 926.9 | 0.603 |
| C2PC for operational characteristics. Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter procedures. End Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Approved for use with antenna(s) as listed in this filing. |
| 20: | All electrical and mechanical devices employed for spurious radiation suppression, including any modifications made during certification testing, must be incorporated in each unit marketed. |
| Mail To: |