FCC ID EP9-TMXM03Z

iConnect Round

by Timex Group USA, Inc.

Grantee Code: EP9   Product Code: TMXM03Z
Latest application date: 2019-01-27

FCC ID Device Details

FCC IDEP9-TMXM03Z
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeEP9
Product CodeTMXM03Z
Applicant BusinessTimex Group USA, Inc. 🇺🇸
Related Domains timexgroup.com
Equipment ClassiConnect Round
Test FirmShenzhen LCS Compliance Testing Laboratory Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2019-01-27
2402-2480 MHzOriginal Equipment2019-01-27

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2019-01-27PDF 1.2 MB
Internal photosInternal Photos2019-01-27PDF 546.6 KB
External photosExternal Photos2019-01-27PDF 492.2 KB
Label and label locationID Label/Location Info2019-01-27PDF 93.3 KB
Letter of declaration label locationCover Letter(s)2019-01-27PDF 112.4 KB
Test setup photosTest Setup Photos2019-01-27PDF 251.8 KB
Appendix A for test data BT ClassicsTest Report2019-01-27PDF 3.5 MB
Appendix B for test data BT LETest Report2019-01-27PDF 1.1 MB
Test Report BT ClassicsTest Report2019-01-27PDF 570.1 KB
Test Report BT LETest Report2019-01-27PDF 481.1 KB
Confidentiality request letterCover Letter(s)2019-01-27PDF 39.5 KB
RF exposure evaluationRF Exposure Info2019-01-27PDF 197.8 KB
Block diagram Metadata onlyBlock DiagramPDF 134.4 KB
Schematic Metadata onlySchematicsPDF 131.8 KB
Operation description Metadata onlyOperational DescriptionPDF 108 KB

Application Information

Application IDzMAENAp550AWiP4A+xrcCw==
Final Action Date2019-01-27
Application PurposeOriginal Equipment
Applicant FRN0023039423
ModelTMXM03Z
Frequency Range2402-2480 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptioniConnect Round
Responsible PartySam Everett, Quality Regulatory Engineer, severett@timexgroup.com , (203) 346-5603
Test FirmGavin Liang, Shenzhen LCS Compliance Testing Laboratory Ltd., gavin.liang@lcs-cert.com , 0755-82591330
TCB Emailtcb-essen@cetecom.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is peak conducted.

Applications

Application IDDatePurpose
zMAENAp550AWiP4A+xrcCw==2019-01-27Original Equipment
LoGZTmEA8k5Gx/S0kQzPlA==2019-01-27Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.001400015C
2402-2480 MHz0.001100015C

Grants

TCB Grant - Application zMAENAp550AWiP4A+xrcCw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CETECOM GmbH
Im Teelbruch 116
45219 Essen,
Germany
Date of Grant: 01/27/2019

Application Dated: 01/27/2019
Timex Group USA, Inc.
555 Christian Road
P.O. Box 310,
Middlebury, CT 06762-0310
 
Attention: Sam Everett , Quality Regulatory Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EP9-TMXM03Z
Name of Grantee:  Timex Group USA, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: iConnect Round
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0011  

Output power listed is peak conducted.

EAS Grant - Application zMAENAp550AWiP4A+xrcCw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Timex Group USA, Inc.
555 Christian Road P.O. Box 310,
Middlebury, CT 06762-0310
United States
  Date of Grant: 01/27/2019

Application Dated: 01/27/2019
 
Attention: Sam Everett , Quality Regulatory Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EP9-TMXM03Z
Name of Grantee:  Timex Group USA, Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: iConnect Round
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0011  

Output power listed is peak conducted.



TCB Grant - Application LoGZTmEA8k5Gx/S0kQzPlA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  CETECOM GmbH
Im Teelbruch 116
45219 Essen,
Germany
Date of Grant: 01/27/2019

Application Dated: 01/27/2019
Timex Group USA, Inc.
555 Christian Road
P.O. Box 310,
Middlebury, CT 06762-0310
 
Attention: Sam Everett , Quality Regulatory Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EP9-TMXM03Z
Name of Grantee:  Timex Group USA, Inc.
Equipment Class: Digital Transmission System
Notes: iConnect Round
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0014  

Output power listed is peak conducted.

EAS Grant - Application LoGZTmEA8k5Gx/S0kQzPlA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Timex Group USA, Inc.
555 Christian Road P.O. Box 310,
Middlebury, CT 06762-0310
United States
  Date of Grant: 01/27/2019

Application Dated: 01/27/2019
 
Attention: Sam Everett , Quality Regulatory Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  EP9-TMXM03Z
Name of Grantee:  Timex Group USA, Inc.
Equipment Class: Digital Transmission System
Notes: iConnect Round
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0014  

Output power listed is peak conducted.



Mail To: