Giteki 001-P00057

CDMA SHI15

MIC source updated 2026-10-19. English translations shown first; original Japanese fields are available on each certificate.

Certificate information

Certificate number
001-P00057
Applicant
Sharp Corporation
Model / equipment
CDMA SHI15
Certification date
2012-04-16
Certifying organization
(Foundation) Telecom Engineering Center
Certification year
2012

Radio equipment and technical records

Radio record 1

Certification date
2012-04-16
Applicant
Sharp Corporation
Model / equipment
CDMA SHI15
Certifying organization
(Foundation) Telecom Engineering Center
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 11
Emission, frequency and power
G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W 824.76~829.23MHz(30kHz spacing 150 channels) 0.316W
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2012-04-16",
    "elecWave": "G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 824.76~829.23MHz(30kHz間隔150波) 0.316W",
    "fqMaintainFunc": "無",
    "name": "シャープ株式会社",
    "note": "",
    "number": "001-P00057",
    "organName": "(一財)テレコムエンジニアリングセンター",
    "radioEquipmentCode": "第2条第11号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "CDMA SHI15"
}

Radio record 2

Certification date
2012-04-16
Applicant
Sharp Corporation
Model / equipment
CDMA SHI15
Certifying organization
(Foundation) Telecom Engineering Center
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 11, Subitem 4
Emission, frequency and power
G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W 1921.25~1938.75MHz(50kHz spacing 351 channels) 0.2W
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2012-04-16",
    "elecWave": "G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 1921.25~1938.75MHz(50kHz間隔351波) 0.2W",
    "fqMaintainFunc": "無",
    "name": "シャープ株式会社",
    "note": "",
    "number": "001-P00057",
    "organName": "(一財)テレコムエンジニアリングセンター",
    "radioEquipmentCode": "第2条第11号の4に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "CDMA SHI15"
}

Radio record 3

Certification date
2012-04-16
Applicant
Sharp Corporation
Model / equipment
CDMA SHI15
Certifying organization
(Foundation) Telecom Engineering Center
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 11, Subitem 8
Emission, frequency and power
G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W 824.76~829.23MHz(30kHz spacing 150 channels) 0.316W G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W 1921.25~1938.75MHz(50kHz spacing 351 channels) 0.2W
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2012-04-16",
    "elecWave": "G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 824.76~829.23MHz(30kHz間隔150波) 0.316W\\nG1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 1921.25~1938.75MHz(50kHz間隔351波) 0.2W",
    "fqMaintainFunc": "無",
    "name": "シャープ株式会社",
    "note": "",
    "number": "001-P00057",
    "organName": "(一財)テレコムエンジニアリングセンター",
    "radioEquipmentCode": "第2条第11号の8に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "CDMA SHI15"
}

Radio record 4

Certification date
2012-04-16
Applicant
Sharp Corporation
Model / equipment
CDMA SHI15
Certifying organization
(Foundation) Telecom Engineering Center
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 11, Subitem 8, Section 2
Emission, frequency and power
G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 824.760~829.230MHz(30kHz spacing150 channels) 0.132W 1922.500~1938.750MHz(50kHz spacing326 channels) 0.070W 1922.500~1938.750MHz(50kHz spacing326 channels) 0.035W 824.760~829.230MHz(30kHz spacing150 channels) 0.132W 1922.500~1938.750MHz(50kHz spacing326 channels) 0.035W 825.375~828.615MHz(30kHz spacing109 channels) 0.132W 1922.500~1938.75MHz(50kHz spacing326 channels) 0.035W 825.990~828.000MHz(30kHz spacing68 channels) 0.132W 1923.125~1938.125MHz(50kHz spacing301 channels) 0.132W 1923.750~1937.500MHz(50kHz spacing276 channels) 0.083W
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2012-04-16",
    "elecWave": "G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W\\n       824.760~829.230MHz(30kHz間隔150波)      0.132W\\n       1922.500~1938.750MHz(50kHz間隔326波)     0.070W\\n        1922.500~1938.750MHz(50kHz間隔326波)     0.035W\\n         824.760~829.230MHz(30kHz間隔150波)      0.132W\\n        1922.500~1938.750MHz(50kHz間隔326波)     0.035W\\n         825.375~828.615MHz(30kHz間隔109波)      0.132W\\n        1922.500~1938.75MHz(50kHz間隔326波)      0.035W\\n         825.990~828.000MHz(30kHz間隔68波)       0.132W\\n        1923.125~1938.125MHz(50kHz間隔301波)     0.132W\\n        1923.750~1937.500MHz(50kHz間隔276波)     0.083W",
    "fqMaintainFunc": "無",
    "name": "シャープ株式会社",
    "note": "",
    "number": "001-P00057",
    "organName": "(一財)テレコムエンジニアリングセンター",
    "radioEquipmentCode": "第2条第11号の8の2に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "CDMA SHI15"
}

Radio record 5

Certification date
2012-04-16
Applicant
Sharp Corporation
Model / equipment
CDMA SHI15
Certifying organization
(Foundation) Telecom Engineering Center
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19
Emission, frequency and power
D1D, G1D 2412~2472MHz (5MHz spacing, 13 channels) 0.00284W/MHz F1A,F1B,F1C,F1D,F1E,F1F,F1W,F1X 2441MHz 0.000024~0.000094W/MHz G1A,G1B,G1C,G1D,G1E,G1F,G1W,G1X 2441MHz 0.000024~0.000094W/MHz G1D 2412~2472MHz (5MHz spacing, 13 channels) 0.00833W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2012-04-16",
    "elecWave": "D1D,G1D 2412~2472MHz(5MHz間隔13波) 0.00284W/MHz\\nF1A,F1B,F1C,F1D,F1E,F1F,F1W,F1X 2441MHz 0.000024~0.000094W/MHz\\nG1A,G1B,G1C,G1D,G1E,G1F,G1W,G1X 2441MHz 0.000024~0.000094W/MHz\\nG1D 2412~2472MHz(5MHz間隔13波) 0.00833W/MHz",
    "fqMaintainFunc": "無",
    "name": "シャープ株式会社",
    "note": "",
    "number": "001-P00057",
    "organName": "(一財)テレコムエンジニアリングセンター",
    "radioEquipmentCode": "第2条第19号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "CDMA SHI15"
}

Radio record 6

Certification date
2012-04-16
Applicant
Sharp Corporation
Model / equipment
CDMA SHI15
Certifying organization
(Foundation) Telecom Engineering Center
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
D1D, G1D 5180~5240MHz (20MHz spacing, 4 channels) 0.0033W/MHz D1D, G1D 5260~5320MHz (20MHz spacing, 4 channels) 0.0033W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2012-04-16",
    "elecWave": "D1D,G1D 5180~5240MHz(20MHz間隔4波) 0.0033W/MHz\\nD1D,G1D 5260~5320MHz(20MHz間隔4波) 0.0033W/MHz",
    "fqMaintainFunc": "無",
    "name": "シャープ株式会社",
    "note": "",
    "number": "001-P00057",
    "organName": "(一財)テレコムエンジニアリングセンター",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "CDMA SHI15"
}

Radio record 7

Certification date
2012-04-16
Applicant
Sharp Corporation
Model / equipment
CDMA SHI15
Certifying organization
(Foundation) Telecom Engineering Center
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3, Section 2
Emission, frequency and power
D1D, G1D 5500~5700MHz (20MHz spacing, 11 channels) 0.00235W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2012-04-16",
    "elecWave": "D1D,G1D 5500~5700MHz(20MHz間隔11波) 0.00235W/MHz",
    "fqMaintainFunc": "無",
    "name": "シャープ株式会社",
    "note": "",
    "number": "001-P00057",
    "organName": "(一財)テレコムエンジニアリングセンター",
    "radioEquipmentCode": "第2条第19号の3の2に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "CDMA SHI15"
}

Photos and test report documents

No attachment documents are listed in this MIC record.

Source: Japan Ministry of Internal Affairs and Communications (MIC). Giteki search · Search FCCID.io