Giteki 001-P01472

W-113A, DD2495A and XH-DD0295

MIC source updated 2026-10-19. English translations shown first; original Japanese fields are available on each certificate.

Certificate information

Certificate number
001-P01472
Applicant
Sharp Corporation
Model / equipment
W-113A, DD2495A and XH-DD0295
Certification date
2020-01-22
Certifying organization
(Foundation) Telecom Engineering Center
Certification year
2020

Radio equipment and technical records

Radio record 1

Certification date
2020-01-22
Applicant
Sharp Corporation
Model / equipment
W-113A, DD2495A and XH-DD0295
Certifying organization
(Foundation) Telecom Engineering Center
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 11, Subitem 3
Emission, frequency and power
5M00 G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W 832.4~842.6MHz (200kHz spacing, 52 channels), 832.5MHz, 837.5MHz, 842.5MHz, 902.6~912.4MHz (200kHz spacing, 50 channels), 1922.6~1977.4MHz (200kHz spacing, 275 channels) 0.25W
Body SAR
Supported
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2020/04/10 [Model or Name] W-113A, DD2495A, XH-DD0295 and PB95 Changed as follows on 2020/05/07 [Model or Name] W-113A, DD2495A, XH-DD0295, PB95 and SH-R50
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "対応",
    "date": "2020-01-22",
    "elecWave": "5M00 G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 832.4~842.6MHz(200kHz間隔52波),832.5MHz,837.5MHz,842.5MHz,902.6~912.4MHz(200kHz間隔50波),1922.6~1977.4MHz(200kHz間隔275波) 0.25W",
    "fqMaintainFunc": "無",
    "name": "シャープ株式会社",
    "note": "変更履歴は次のとおり。\\n・2020年04月10日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295及びPB95\\n・2020年05月07日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295,PB95及びSH-R50",
    "number": "001-P01472",
    "organName": "(一財)テレコムエンジニアリングセンター",
    "radioEquipmentCode": "第2条第11号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "W-113A,DD2495A及びXH-DD0295"
}

Radio record 2

Certification date
2020-01-22
Applicant
Sharp Corporation
Model / equipment
W-113A, DD2495A and XH-DD0295
Certifying organization
(Foundation) Telecom Engineering Center
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 11, Subitem 7
Emission, frequency and power
5M00 G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W 832.4~842.6MHz (200kHz spacing, 52 channels), 832.5MHz, 837.5MHz, 842.5MHz, 902.6~912.4MHz (200kHz spacing, 50 channels), 1922.6~1977.4MHz (200kHz spacing, 275 channels) 0.25W
Body SAR
Supported
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2020/04/10 [Model or Name] W-113A, DD2495A, XH-DD0295 and PB95 Changed as follows on 2020/05/07 [Model or Name] W-113A, DD2495A, XH-DD0295, PB95 and SH-R50
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "対応",
    "date": "2020-01-22",
    "elecWave": "5M00 G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 832.4~842.6MHz(200kHz間隔52波),832.5MHz,837.5MHz,842.5MHz,902.6~912.4MHz(200kHz間隔50波),1922.6~1977.4MHz(200kHz間隔275波) 0.25W",
    "fqMaintainFunc": "無",
    "name": "シャープ株式会社",
    "note": "変更履歴は次のとおり。\\n・2020年04月10日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295及びPB95\\n・2020年05月07日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295,PB95及びSH-R50",
    "number": "001-P01472",
    "organName": "(一財)テレコムエンジニアリングセンター",
    "radioEquipmentCode": "第2条第11号の7に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "W-113A,DD2495A及びXH-DD0295"
}

Radio record 3

Certification date
2020-01-22
Applicant
Sharp Corporation
Model / equipment
W-113A, DD2495A and XH-DD0295
Certifying organization
(Foundation) Telecom Engineering Center
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 11, Subitem 19
Emission, frequency and power
5M00 D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 720.5~745.5MHz(100kHz spacing251 channels),817.5~827.5MHz(100kHz spacing101 channels),832.5~842.5MHz(100kHz spacing101 channels),902.5~907.4MHz(100kHz spacing50 channels, but the frequencies that can be transmitted simultaneously must be continuous within a width of 3.6MHz),907.5~912.5MHz(100kHz spacing51 channels),1430.4~1445.4MHz(100kHz spacing151 channels),1712.5~1782.5MHz(100kHz spacing701 channels),1927.2~1977.5MHz(100kHz spacing504 channels) 23dBm 10M0 D1A, D1B, D1C, D1D, D1E, D1F, D1X, D7W, G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W 723.0~743.0MHz (100kHz spacing, 201 channels), 723MHz (simultaneous transmission frequencies are continuous maximum 5.4MHz width among those from 718.86MHz to 727.14MHz), 820.0~825.0MHz (100kHz spacing, 51 channels), 835.0~840.0MHz (100kHz spacing, 51 channels), 910MHz (simultaneous transmission frequencies are continuous maximum 5.76MHz width among those from 906.22MHz to 914.5MHz), 1432.9~1442.9MHz (100kHz spacing, 101 channels), 1715.0~1780.0MHz (100kHz spacing, 651 channels), 1934.7~1975.0MHz (100kHz spacing, 404 channels) 23dBm 15M0 D1A, D1B, D1C, D1D, D1E, D1F, D1X, D7W, G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W 725.5~740.5MHz (100kHz spacing, 151 channels), 822.5MHz, 837.5MHz, 1717.5~1777.5MHz (100kHz spacing, 601 channels), 1932.5MHz, 1942.2~1972.5MHz (100kHz spacing, 304 channels) 23dBm 20M0 D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 728.0~738.0MHz(100kHz spacing 101 channels),1720.0~1775.0MHz(100kHz spacing 551 channels),1930MHz,1949.7~1970.0MHz(100kHz spacing 204 channels) 23dBm
Body SAR
Supported
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2020/04/10 [Model or Name] W-113A, DD2495A, XH-DD0295 and PB95 Changed as follows on 2020/05/07 [Model or Name] W-113A, DD2495A, XH-DD0295, PB95 and SH-R50
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "対応",
    "date": "2020-01-22",
    "elecWave": "5M00 D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 720.5~745.5MHz(100kHz間隔251波),817.5~827.5MHz(100kHz間隔101波),832.5~842.5MHz(100kHz間隔101波),902.5~907.4MHz(100kHz間隔50波ただし同時送信可能な周波数は連続した3.6MHz幅),907.5~912.5MHz(100kHz間隔51波),1430.4~1445.4MHz(100kHz間隔151波),1712.5~1782.5MHz(100kHz間隔701波),1927.2~1977.5MHz(100kHz間隔504波) 23dBm\\n10M0 D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 723.0~743.0MHz(100kHz間隔201波),723MHz(同時送信可能な周波数は718.86MHzから727.14MHzまでのうち連続した最大5.4MHz幅),820.0~825.0MHz(100kHz間隔51波),835.0~840.0MHz(100kHz間隔51波),910MHz(同時送信可能な周波数は906.22MHzから914.5MHzまでのうち連続した最大5.76MHz幅),1432.9~1442.9MHz(100kHz間隔101波),1715.0~1780.0MHz(100kHz間隔651波),1934.7~1975.0MHz(100kHz間隔404波) 23dBm\\n15M0 D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 725.5~740.5MHz(100kHz間隔151波),822.5MHz,837.5MHz,1717.5~1777.5MHz(100kHz間隔601波),1932.5MHz,1942.2~1972.5MHz(100kHz間隔304波) 23dBm\\n20M0 D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 728.0~738.0MHz(100kHz間隔101波),1720.0~1775.0MHz(100kHz間隔551波),1930MHz,1949.7~1970.0MHz(100kHz間隔204波) 23dBm",
    "fqMaintainFunc": "無",
    "name": "シャープ株式会社",
    "note": "変更履歴は次のとおり。\\n・2020年04月10日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295及びPB95\\n・2020年05月07日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295,PB95及びSH-R50",
    "number": "001-P01472",
    "organName": "(一財)テレコムエンジニアリングセンター",
    "radioEquipmentCode": "第2条第11号の19に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "W-113A,DD2495A及びXH-DD0295"
}

Radio record 4

Certification date
2020-01-22
Applicant
Sharp Corporation
Model / equipment
W-113A, DD2495A and XH-DD0295
Certifying organization
(Foundation) Telecom Engineering Center
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 11, Subitem 21
Emission, frequency and power
5M00 D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 3402.5~3597.5MHz(100kHz spacing1951 channels) 23dBm 10M0 D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 3405.0~3595.0MHz(100kHz spacing1901 channels) 23dBm 15M0 D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 3407.5~3592.5MHz(100kHz spacing1851 channels) 23dBm 20M0 D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 3410.0~3590.0MHz(100kHz spacing1801 channels) 23dBm 39M8 D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 3419.9~3580.1MHz(100kHz spacing1603 channels) 23dBm
Body SAR
Supported
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2020/04/10 [Model or Name] W-113A, DD2495A, XH-DD0295 and PB95 Changed as follows on 2020/05/07 [Model or Name] W-113A, DD2495A, XH-DD0295, PB95 and SH-R50
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "対応",
    "date": "2020-01-22",
    "elecWave": "5M00 D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 3402.5~3597.5MHz(100kHz間隔1951波) 23dBm\\n10M0 D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 3405.0~3595.0MHz(100kHz間隔1901波) 23dBm\\n15M0 D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 3407.5~3592.5MHz(100kHz間隔1851波) 23dBm\\n20M0 D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 3410.0~3590.0MHz(100kHz間隔1801波) 23dBm\\n39M8 D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 3419.9~3580.1MHz(100kHz間隔1603波) 23dBm",
    "fqMaintainFunc": "無",
    "name": "シャープ株式会社",
    "note": "変更履歴は次のとおり。\\n・2020年04月10日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295及びPB95\\n・2020年05月07日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295,PB95及びSH-R50",
    "number": "001-P01472",
    "organName": "(一財)テレコムエンジニアリングセンター",
    "radioEquipmentCode": "第2条第11号の21に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "W-113A,DD2495A及びXH-DD0295"
}

Radio record 5

Certification date
2020-01-22
Applicant
Sharp Corporation
Model / equipment
W-113A, DD2495A and XH-DD0295
Certifying organization
(Foundation) Telecom Engineering Center
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 11, Subitem 30
Emission, frequency and power
100M D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 3.65001~4.05000GHz(30kHz spacing13334 channels) 0.2W
Body SAR
Supported
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2020/04/10 [Model or Name] W-113A, DD2495A, XH-DD0295 and PB95 Changed as follows on 2020/05/07 [Model or Name] W-113A, DD2495A, XH-DD0295, PB95 and SH-R50
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "対応",
    "date": "2020-01-22",
    "elecWave": "100M D1A,D1B,D1C,D1D,D1E,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 3.65001~4.05000GHz(30kHz間隔13334波) 0.2W",
    "fqMaintainFunc": "無",
    "name": "シャープ株式会社",
    "note": "変更履歴は次のとおり。\\n・2020年04月10日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295及びPB95\\n・2020年05月07日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295,PB95及びSH-R50",
    "number": "001-P01472",
    "organName": "(一財)テレコムエンジニアリングセンター",
    "radioEquipmentCode": "第2条第11号の30に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "W-113A,DD2495A及びXH-DD0295"
}

Radio record 6

Certification date
2020-01-22
Applicant
Sharp Corporation
Model / equipment
W-113A, DD2495A and XH-DD0295
Certifying organization
(Foundation) Telecom Engineering Center
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19
Emission, frequency and power
G1D 2412~2472MHz(5MHz spacing13 channels) 0.005W/MHz,0.01W/MHz D1D,G1D 2412~2472MHz(5MHz spacing13 channels) 0.00127~0.005W/MHz,0.00254~0.01W/MHz D1D,G1D 2422~2462MHz(5MHz spacing9 channels) 0.000635~0.0025W/MHz,0.00127~0.005W/MHz F1D 2402~2480MHz (2000kHz spacing, 40 channels) 0.01W F1A,F1B,F1C,F1D,F1E,F1F,F1W,F1X 2441MHz 0.000219~0.000855W/MHz G1A,G1B,G1C,G1D,G1E,G1F,G1W,G1X 2441MHz 0.000212~0.000825W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2020/04/10 [Model or Name] W-113A, DD2495A, XH-DD0295 and PB95 Changed as follows on 2020/05/07 [Model or Name] W-113A, DD2495A, XH-DD0295, PB95 and SH-R50
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2020-01-22",
    "elecWave": "G1D 2412~2472MHz(5MHz間隔13波) 0.005W/MHz,0.01W/MHz\\nD1D,G1D 2412~2472MHz(5MHz間隔13波) 0.00127~0.005W/MHz,0.00254~0.01W/MHz\\nD1D,G1D 2422~2462MHz(5MHz間隔9波) 0.000635~0.0025W/MHz,0.00127~0.005W/MHz\\nF1D 2402~2480MHz(2000kHz間隔40波) 0.01W\\nF1A,F1B,F1C,F1D,F1E,F1F,F1W,F1X 2441MHz 0.000219~0.000855W/MHz\\nG1A,G1B,G1C,G1D,G1E,G1F,G1W,G1X 2441MHz 0.000212~0.000825W/MHz",
    "fqMaintainFunc": "無",
    "name": "シャープ株式会社",
    "note": "変更履歴は次のとおり。\\n・2020年04月10日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295及びPB95\\n・2020年05月07日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295,PB95及びSH-R50",
    "number": "001-P01472",
    "organName": "(一財)テレコムエンジニアリングセンター",
    "radioEquipmentCode": "第2条第19号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "W-113A,DD2495A及びXH-DD0295"
}

Radio record 7

Certification date
2020-01-22
Applicant
Sharp Corporation
Model / equipment
W-113A, DD2495A and XH-DD0295
Certifying organization
(Foundation) Telecom Engineering Center
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
D1D,G1D 5.18~5.24GHz(20MHz spacing4 channels) 0.001725~0.005W/MHz,0.00345~0.01W/MHz D1D,G1D 5.26~5.32GHz(20MHz spacing4 channels) 0.001725~0.005W/MHz,0.00345~0.01W/MHz D1D,G1D 5.50~5.72GHz(20MHz spacing12 channels) 0.001125~0.003975W/MHz,0.00225~0.00795W/MHz D1D,G1D 5.19~5.31GHz(40MHz spacing4 channels) 0.0009~0.0025W/MHz,0.0018~0.005W/MHz D1D,G1D 5.51~5.71GHz(40MHz spacing6 channels) 0.00055~0.00205W/MHz,0.0011~0.0041W/MHz D1D,G1D 5.21GHz,5.29GHz 0.000405~0.00125W/MHz,0.00081~0.0025W/MHz D1D,G1D 5.53~5.69GHz(80MHz spacing3 channels) 0.00028~0.001045W/MHz,0.00056~0.00209W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2020/04/10 [Model or Name] W-113A, DD2495A, XH-DD0295 and PB95 Changed as follows on 2020/05/07 [Model or Name] W-113A, DD2495A, XH-DD0295, PB95 and SH-R50
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2020-01-22",
    "elecWave": "D1D,G1D 5.18~5.24GHz(20MHz間隔4波) 0.001725~0.005W/MHz,0.00345~0.01W/MHz\\nD1D,G1D 5.26~5.32GHz(20MHz間隔4波) 0.001725~0.005W/MHz,0.00345~0.01W/MHz\\nD1D,G1D 5.50~5.72GHz(20MHz間隔12波) 0.001125~0.003975W/MHz,0.00225~0.00795W/MHz\\nD1D,G1D 5.19~5.31GHz(40MHz間隔4波) 0.0009~0.0025W/MHz,0.0018~0.005W/MHz\\nD1D,G1D 5.51~5.71GHz(40MHz間隔6波) 0.00055~0.00205W/MHz,0.0011~0.0041W/MHz\\nD1D,G1D 5.21GHz,5.29GHz 0.000405~0.00125W/MHz,0.00081~0.0025W/MHz\\nD1D,G1D 5.53~5.69GHz(80MHz間隔3波) 0.00028~0.001045W/MHz,0.00056~0.00209W/MHz",
    "fqMaintainFunc": "無",
    "name": "シャープ株式会社",
    "note": "変更履歴は次のとおり。\\n・2020年04月10日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295及びPB95\\n・2020年05月07日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295,PB95及びSH-R50",
    "number": "001-P01472",
    "organName": "(一財)テレコムエンジニアリングセンター",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "W-113A,DD2495A及びXH-DD0295"
}

Radio record 8

Certification date
2020-01-22
Applicant
Sharp Corporation
Model / equipment
W-113A, DD2495A and XH-DD0295
Certifying organization
(Foundation) Telecom Engineering Center
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
D1D,G1D 5.50~5.72GHz(20MHz spacing12 channels) 0.001125~0.003975W/MHz,0.00225~0.00795W/MHz D1D,G1D 5.51~5.71GHz(40MHz spacing6 channels) 0.00055~0.00205W/MHz,0.0011~0.0041W/MHz D1D,G1D 5.53~5.69GHz(80MHz spacing3 channels) 0.00028~0.001045W/MHz,0.00056~0.00209W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2020/04/10 [Model or Name] W-113A, DD2495A, XH-DD0295 and PB95 Changed as follows on 2020/05/07 [Model or Name] W-113A, DD2495A, XH-DD0295, PB95 and SH-R50
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2020-01-22",
    "elecWave": "D1D,G1D 5.50~5.72GHz(20MHz間隔12波) 0.001125~0.003975W/MHz,0.00225~0.00795W/MHz\\nD1D,G1D 5.51~5.71GHz(40MHz間隔6波) 0.00055~0.00205W/MHz,0.0011~0.0041W/MHz\\nD1D,G1D 5.53~5.69GHz(80MHz間隔3波) 0.00028~0.001045W/MHz,0.00056~0.00209W/MHz",
    "fqMaintainFunc": "無",
    "name": "シャープ株式会社",
    "note": "変更履歴は次のとおり。\\n・2020年04月10日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295及びPB95\\n・2020年05月07日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295,PB95及びSH-R50",
    "number": "001-P01472",
    "organName": "(一財)テレコムエンジニアリングセンター",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "W-113A,DD2495A及びXH-DD0295"
}

Radio record 9

Certification date
2020-01-22
Applicant
Sharp Corporation
Model / equipment
W-113A, DD2495A and XH-DD0295
Certifying organization
(Foundation) Telecom Engineering Center
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 54
Emission, frequency and power
5M00 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2547.5~2652.5MHz(100kHz spacing1051 channels) 26dBm 10M0 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2550.0~2650.0MHz(100kHz spacing1001 channels) 26dBm 20M0 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2555.0~2564.9MHz(100kHz spacing100 channels) 23dBm 20M0 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2565.0~2645.0MHz(100kHz spacing801 channels) 26dBm 29M9 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2610.25MHz 23dBm 39M8 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2625.1MHz 23dBm
Body SAR
Supported
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2020/04/10 [Model or Name] W-113A, DD2495A, XH-DD0295 and PB95 Changed as follows on 2020/05/07 [Model or Name] W-113A, DD2495A, XH-DD0295, PB95 and SH-R50
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "対応",
    "date": "2020-01-22",
    "elecWave": "5M00 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2547.5~2652.5MHz(100kHz間隔1051波) 26dBm\\n10M0 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2550.0~2650.0MHz(100kHz間隔1001波) 26dBm\\n20M0 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2555.0~2564.9MHz(100kHz間隔100波) 23dBm\\n20M0 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2565.0~2645.0MHz(100kHz間隔801波) 26dBm\\n29M9 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2610.25MHz 23dBm\\n39M8 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2625.1MHz 23dBm",
    "fqMaintainFunc": "無",
    "name": "シャープ株式会社",
    "note": "変更履歴は次のとおり。\\n・2020年04月10日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295及びPB95\\n・2020年05月07日に下記のとおり変更\\n【型式又は名称】W-113A,DD2495A,XH-DD0295,PB95及びSH-R50",
    "number": "001-P01472",
    "organName": "(一財)テレコムエンジニアリングセンター",
    "radioEquipmentCode": "第2条第54号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "W-113A,DD2495A及びXH-DD0295"
}

Photos and test report documents

No attachment documents are listed in this MIC record.

Source: Japan Ministry of Internal Affairs and Communications (MIC). Giteki search · Search FCCID.io