Giteki 003-190270

TC400JU, TC500JU or TC600JU

MIC source updated 2026-10-19. English translations shown first; original Japanese fields are available on each certificate.

Certificate information

Certificate number
003-190270
Applicant
USEN Co., Ltd.
Model / equipment
TC400JU, TC500JU or TC600JU
Certification date
2020-01-29
Certifying organization
DSP Research Co., Ltd.
Certification year
2020

Radio equipment and technical records

Radio record 1

Certification date
2020-01-29
Applicant
USEN Co., Ltd.
Model / equipment
TC400JU, TC500JU or TC600JU
Certifying organization
DSP Research Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
D1D,G1D 5.18~5.32GHz(20MHz spacing8 channels) 0.00263W/MHz,0.00261W/MHz D1D,G1D 5.19GHz,5.23GHz,5.27GHz,5.31GHz 0.00134W/MHz D1D,G1D 5.21GHz,5.29GHz 0.00086W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2020-01-29",
    "elecWave": "D1D,G1D 5.18~5.32GHz(20MHz間隔8波) 0.00263W/MHz,0.00261W/MHz\\nD1D,G1D 5.19GHz,5.23GHz,5.27GHz,5.31GHz 0.00134W/MHz\\nD1D,G1D 5.21GHz,5.29GHz 0.00086W/MHz",
    "fqMaintainFunc": "無",
    "name": "株式会社USEN",
    "note": "",
    "number": "003-190270",
    "organName": "(株)ディーエスピーリサーチ",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "TC400JU, TC500JU 又は TC600JU"
}

Radio record 2

Certification date
2020-01-29
Applicant
USEN Co., Ltd.
Model / equipment
TC400JU, TC500JU or TC600JU
Certifying organization
DSP Research Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3, Section 2
Emission, frequency and power
D1D, G1D 5.50~5.70GHz (20MHz spacing, 11 channels) 0.0021W/MHz D1D, G1D 5.51~5.67GHz (40MHz spacing, 5 channels) 0.0011W/MHz D1D,G1D 5.53GHz,5.61GHz 0.0008W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2020-01-29",
    "elecWave": "D1D,G1D 5.50~5.70GHz(20MHz間隔11波) 0.0021W/MHz\\nD1D,G1D 5.51~5.67GHz(40MHz間隔5波) 0.0011W/MHz\\nD1D,G1D 5.53GHz,5.61GHz 0.0008W/MHz",
    "fqMaintainFunc": "無",
    "name": "株式会社USEN",
    "note": "",
    "number": "003-190270",
    "organName": "(株)ディーエスピーリサーチ",
    "radioEquipmentCode": "第2条第19号の3の2に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "TC400JU, TC500JU 又は TC600JU"
}

Photos and test report documents

No attachment documents are listed in this MIC record.

Source: Japan Ministry of Internal Affairs and Communications (MIC). Giteki search · Search FCCID.io