Giteki 005-100084

FMP108-NADESHIKO

MIC source updated 2026-10-19. English translations shown first; original Japanese fields are available on each certificate.

Certificate information

Certificate number
005-100084
Applicant
Fujitsu Limited
Model / equipment
FMP108-NADESHIKO
Certification date
2012-03-30
Certifying organization
TUV Rheinland Japan Co., Ltd.
Certification year
2012

Radio equipment and technical records

Radio record 1

Certification date
2012-03-30
Applicant
Fujitsu Limited
Model / equipment
FMP108-NADESHIKO
Certifying organization
TUV Rheinland Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 11, Subitem 3
Emission, frequency and power
G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W 832.4~842.6MHz (200kHz spacing, 52 channels) 0.25W 832.5z, 837.5, 842.5MHz 0.25W 1752.4~1782.4MHz (200kHz spacing, 151 channels) 0.25W 1922.6~1977.4MHz (200kHz spacing, 275 channels) 0.25W
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2016/02/01 [Name] Fujitsu Connected Technologies Changed as follows on 2021/04/01 [Name or Title] FCNT Co., Ltd.
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2012-03-30",
    "elecWave": "G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 832.4~842.6MHz(200kHz間隔52波) 0.25W 832.5z,837.5,842.5MHz 0.25W 1752.4~1782.4MHz(200kHz間隔151波) 0.25W 1922.6~1977.4MHz(200kHz間隔275波) 0.25W",
    "fqMaintainFunc": "無",
    "name": "富士通株式会社",
    "note": "変更履歴は次のとおり。\\n・2016年02月01日に下記のとおり変更\\n【氏名又は名称】富士通コネクテッドテクノロジーズ\\n・2021年04月01日に下記のとおり変更\\n【氏名又は名称】FCNT株式会社",
    "number": "005-100084",
    "organName": "テュフ・ラインランド・ジャパン(株)",
    "radioEquipmentCode": "第2条第11号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "FMP108-NADESHIKO"
}

Radio record 2

Certification date
2012-03-30
Applicant
Fujitsu Limited
Model / equipment
FMP108-NADESHIKO
Certifying organization
TUV Rheinland Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 11, Subitem 7
Emission, frequency and power
G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W 832.4~842.6MHz (200kHz spacing, 52 channels) 0.25W 832.5, 837.5, 842.5MHz 0.25W 1752.4~1782.4MHz (200kHz spacing, 151 channels) 0.25W 1922.6~1977.4MHz (200kHz spacing, 275 channels) 0.25W
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2016/02/01 [Name] Fujitsu Connected Technologies Changed as follows on 2021/04/01 [Name or Title] FCNT Co., Ltd.
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2012-03-30",
    "elecWave": "G1A,G1B,G1C,G1D,G1E,G1F,G1X,G7W 832.4~842.6MHz(200kHz間隔52波) 0.25W 832.5,837.5,842.5MHz 0.25W 1752.4~1782.4MHz(200kHz間隔151波) 0.25W 1922.6~1977.4MHz(200kHz間隔275波) 0.25W",
    "fqMaintainFunc": "無",
    "name": "富士通株式会社",
    "note": "変更履歴は次のとおり。\\n・2016年02月01日に下記のとおり変更\\n【氏名又は名称】富士通コネクテッドテクノロジーズ\\n・2021年04月01日に下記のとおり変更\\n【氏名又は名称】FCNT株式会社",
    "number": "005-100084",
    "organName": "テュフ・ラインランド・ジャパン(株)",
    "radioEquipmentCode": "第2条第11号の7に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "FMP108-NADESHIKO"
}

Radio record 3

Certification date
2012-03-30
Applicant
Fujitsu Limited
Model / equipment
FMP108-NADESHIKO
Certifying organization
TUV Rheinland Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19
Emission, frequency and power
D1D, G1D 2412~2472MHz (5MHz spacing, 13 channels) 0.0029W/MHz D1D, G1D 2412~2472MHz (5MHz spacing, 13 channels) 0.0028W/MHz G1D 2412~2472MHz (5MHz spacing, 13 channels) 0.0042W/MHz F1D 2402~2480MHz (2MHz spacing, 40 channels) 0.00051W F1D,F1E,F1W,G1D,G1E,G1W 2441MHz 0.000028~0.000110W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2016/02/01 [Name] Fujitsu Connected Technologies Changed as follows on 2021/04/01 [Name or Title] FCNT Co., Ltd.
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2012-03-30",
    "elecWave": "D1D,G1D 2412~2472MHz(5MHz間隔13波) 0.0029W/MHz\\nD1D,G1D 2412~2472MHz(5MHz間隔13波) 0.0028W/MHz\\nG1D 2412~2472MHz(5MHz間隔13波) 0.0042W/MHz\\nF1D 2402~2480MHz(2MHz間隔40波) 0.00051W\\nF1D,F1E,F1W,G1D,G1E,G1W 2441MHz 0.000028~0.000110W/MHz",
    "fqMaintainFunc": "無",
    "name": "富士通株式会社",
    "note": "変更履歴は次のとおり。\\n・2016年02月01日に下記のとおり変更\\n【氏名又は名称】富士通コネクテッドテクノロジーズ\\n・2021年04月01日に下記のとおり変更\\n【氏名又は名称】FCNT株式会社",
    "number": "005-100084",
    "organName": "テュフ・ラインランド・ジャパン(株)",
    "radioEquipmentCode": "第2条第19号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "FMP108-NADESHIKO"
}