Giteki 005-100717

FMP132-ASAGAO

MIC source updated 2026-10-19. English translations shown first; original Japanese fields are available on each certificate.

Certificate information

Certificate number
005-100717
Applicant
Fujitsu Limited
Model / equipment
FMP132-ASAGAO
Certification date
2014-03-27
Certifying organization
TUV Rheinland Japan Co., Ltd.
Certification year
2014

Radio equipment and technical records

Radio record 1

Certification date
2014-03-27
Applicant
Fujitsu Limited
Model / equipment
FMP132-ASAGAO
Certifying organization
TUV Rheinland Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19
Emission, frequency and power
D1D,G1D 2412~2472MHz(5MHz spacing13 channels) 0.00176,0.00295W/MHz G1D 2412~2472MHz (5MHz spacing, 13 channels) 0.00451W/MHz F1D 2402~2480MHz (2000kHz spacing, 40 channels) 0.0020W F1D,F1E,F1W,G1D,G1E,G1W 2441MHz 0.000101~0.000397W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2016/02/01 [Name] Fujitsu Connected Technologies Changed as follows on 2021/04/01 [Name or Title] FCNT Co., Ltd.
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2014-03-27",
    "elecWave": "D1D,G1D 2412~2472MHz(5MHz間隔13波) 0.00176,0.00295W/MHz\\nG1D 2412~2472MHz(5MHz間隔13波) 0.00451W/MHz\\nF1D 2402~2480MHz(2000kHz間隔40波) 0.0020W\\nF1D,F1E,F1W,G1D,G1E,G1W 2441MHz 0.000101~0.000397W/MHz",
    "fqMaintainFunc": "無",
    "name": "富士通株式会社",
    "note": "変更履歴は次のとおり。\\n・2016年02月01日に下記のとおり変更\\n【氏名又は名称】富士通コネクテッドテクノロジーズ\\n・2021年04月01日に下記のとおり変更\\n【氏名又は名称】FCNT株式会社",
    "number": "005-100717",
    "organName": "テュフ・ラインランド・ジャパン(株)",
    "radioEquipmentCode": "第2条第19号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "FMP132-ASAGAO"
}

Radio record 2

Certification date
2014-03-27
Applicant
Fujitsu Limited
Model / equipment
FMP132-ASAGAO
Certifying organization
TUV Rheinland Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
D1D, G1D 5.18~5.32GHz (20MHz spacing, 8 channels) 0.00278, 0.00295W/MHz D1D, G1D 5.19~5.31GHz (40MHz spacing, 4 channels) 0.000878, 0.00111W/MHz D1D, G1D 5.21~5.29GHz (80MHz spacing, 2 channels) 0.000335W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2016/02/01 [Name] Fujitsu Connected Technologies Changed as follows on 2021/04/01 [Name or Title] FCNT Co., Ltd.
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2014-03-27",
    "elecWave": "D1D,G1D 5.18~5.32GHz(20MHz間隔8波) 0.00278, 0.00295W/MHz\\nD1D,G1D 5.19~5.31GHz(40MHz間隔4波) 0.000878, 0.00111W/MHz\\nD1D,G1D 5.21~5.29GHz(80MHz間隔2波) 0.000335W/MHz",
    "fqMaintainFunc": "無",
    "name": "富士通株式会社",
    "note": "変更履歴は次のとおり。\\n・2016年02月01日に下記のとおり変更\\n【氏名又は名称】富士通コネクテッドテクノロジーズ\\n・2021年04月01日に下記のとおり変更\\n【氏名又は名称】FCNT株式会社",
    "number": "005-100717",
    "organName": "テュフ・ラインランド・ジャパン(株)",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "FMP132-ASAGAO"
}

Radio record 3

Certification date
2014-03-27
Applicant
Fujitsu Limited
Model / equipment
FMP132-ASAGAO
Certifying organization
TUV Rheinland Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3, Section 2
Emission, frequency and power
D1D, G1D 5.50~5.70GHz (20MHz spacing, 11 channels) 0.00140, 0.00148W/MHz D1D, G1D 5.51~5.67GHz (40MHz spacing, 5 channels) 0.000554, 0.000698W/MHz D1D, G1D 5.53~5.61GHz (80MHz spacing, 2 channels) 0.000168W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2016/02/01 [Name] Fujitsu Connected Technologies Changed as follows on 2021/04/01 [Name or Title] FCNT Co., Ltd.
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2014-03-27",
    "elecWave": "D1D,G1D 5.50~5.70GHz(20MHz間隔11波) 0.00140, 0.00148W/MHz\\nD1D,G1D 5.51~5.67GHz(40MHz間隔5波) 0.000554, 0.000698W/MHz\\nD1D,G1D 5.53~5.61GHz(80MHz間隔2波) 0.000168W/MHz",
    "fqMaintainFunc": "無",
    "name": "富士通株式会社",
    "note": "変更履歴は次のとおり。\\n・2016年02月01日に下記のとおり変更\\n【氏名又は名称】富士通コネクテッドテクノロジーズ\\n・2021年04月01日に下記のとおり変更\\n【氏名又は名称】FCNT株式会社",
    "number": "005-100717",
    "organName": "テュフ・ラインランド・ジャパン(株)",
    "radioEquipmentCode": "第2条第19号の3の2に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "FMP132-ASAGAO"
}

Photos and test report documents

No attachment documents are listed in this MIC record.

Source: Japan Ministry of Internal Affairs and Communications (MIC). Giteki search · Search FCCID.io