Giteki 005-100995

NR-213

MIC source updated 2026-10-19. English translations shown first; original Japanese fields are available on each certificate.

Certificate information

Certificate number
005-100995
Applicant
Mitsubishi Electric Corporation
Model / equipment
NR-213
Certification date
2023-03-14
Certifying organization
TUV Rheinland Japan Co., Ltd.
Certification year
2023

Radio equipment and technical records

Radio record 1

Certification date
2023-03-14
Applicant
Mitsubishi Electric Corporation
Model / equipment
NR-213
Certifying organization
TUV Rheinland Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19
Emission, frequency and power
D1D, G1D 2412~2472MHz (5MHz spacing, 13 channels) 0.00090W/MHz G1D 2412~2472MHz (5MHz spacing, 13 channels) 0.00335W/MHz F1D 2441MHz 0.000020~0.000080W/MHz G1D 2441MHz 0.000015~0.000060W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2024/10/09 [Name or Title] Mitsubishi Electric Mobility Corporation
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2023-03-14",
    "elecWave": "D1D,G1D 2412~2472MHz(5MHz間隔13波) 0.00090W/MHz\\nG1D 2412~2472MHz(5MHz間隔13波) 0.00335W/MHz\\nF1D 2441MHz 0.000020~0.000080W/MHz\\nG1D 2441MHz 0.000015~0.000060W/MHz",
    "fqMaintainFunc": "無",
    "name": "三菱電機株式会社",
    "note": "変更履歴は次のとおり。\\n・2024年10月09日に下記のとおり変更\\n【氏名又は名称】三菱電機モビリティ株式会社",
    "number": "005-100995",
    "organName": "テュフ・ラインランド・ジャパン(株)",
    "radioEquipmentCode": "第2条第19号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "NR-213"
}

Radio record 2

Certification date
2015-05-27
Applicant
Mitsubishi Electric Corporation
Model / equipment
NR-213
Certifying organization
TUV Rheinland Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19
Emission, frequency and power
D1D, G1D 2412~2472MHz(5MHz spacing13 channels) 0.00090W/MHz G1D 2412~2472MHz (5MHz spacing, 13 channels) 0.00335W/MHz F1D 2441MHz 0.000020~0.000080W/MHz G1D 2441MHz 0.000015~0.000060W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2024/10/09 [Name or Title] Mitsubishi Electric Mobility Corporation
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2015-05-27",
    "elecWave": "D1D, G1D 2412~2472MHz(5MHz間隔13波) 0.00090W/MHz\\nG1D 2412~2472MHz(5MHz間隔13波) 0.00335W/MHz\\nF1D 2441MHz 0.000020~0.000080W/MHz\\nG1D 2441MHz 0.000015~0.000060W/MHz",
    "fqMaintainFunc": "無",
    "name": "三菱電機株式会社",
    "note": "変更履歴は次のとおり。\\n・2024年10月09日に下記のとおり変更\\n【氏名又は名称】三菱電機モビリティ株式会社",
    "number": "005-100995",
    "organName": "テュフ・ラインランド・ジャパン(株)",
    "radioEquipmentCode": "第2条第19号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "NR-213"
}

Radio record 3

Certification date
2023-03-14
Applicant
Mitsubishi Electric Corporation
Model / equipment
NR-213
Certifying organization
TUV Rheinland Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
D1D,G1D 5.18~5.32GHz(20MHz spacing8 channels) 0.00018W/MHz,0.00022W/MHz D1D, G1D 5.19~5.31GHz (40MHz spacing, 4 channels) 0.00009W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2024/10/09 [Name or Title] Mitsubishi Electric Mobility Corporation
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2023-03-14",
    "elecWave": "D1D,G1D 5.18~5.32GHz(20MHz間隔8波) 0.00018W/MHz,0.00022W/MHz\\nD1D,G1D 5.19~5.31GHz(40MHz間隔4波) 0.00009W/MHz",
    "fqMaintainFunc": "無",
    "name": "三菱電機株式会社",
    "note": "変更履歴は次のとおり。\\n・2024年10月09日に下記のとおり変更\\n【氏名又は名称】三菱電機モビリティ株式会社",
    "number": "005-100995",
    "organName": "テュフ・ラインランド・ジャパン(株)",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "NR-213"
}

Radio record 4

Certification date
2015-05-27
Applicant
Mitsubishi Electric Corporation
Model / equipment
NR-213
Certifying organization
TUV Rheinland Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
D1D, G1D 5.18~5.32GHz(20MHz spacing8 channels) 0.00018, 0.00022W/MHz 5.19~5.31GHz(40MHz spacing4 channels) 0.00009W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2024/10/09 [Name or Title] Mitsubishi Electric Mobility Corporation
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2015-05-27",
    "elecWave": "D1D, G1D\\n5.18~5.32GHz(20MHz間隔8波) 0.00018, 0.00022W/MHz\\n5.19~5.31GHz(40MHz間隔4波) 0.00009W/MHz",
    "fqMaintainFunc": "無",
    "name": "三菱電機株式会社",
    "note": "変更履歴は次のとおり。\\n・2024年10月09日に下記のとおり変更\\n【氏名又は名称】三菱電機モビリティ株式会社",
    "number": "005-100995",
    "organName": "テュフ・ラインランド・ジャパン(株)",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "NR-213"
}

Radio record 5

Certification date
2023-03-14
Applicant
Mitsubishi Electric Corporation
Model / equipment
NR-213
Certifying organization
TUV Rheinland Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3, Section 2
Emission, frequency and power
D1D, G1D 5.50~5.70GHz (20MHz spacing, 11 channels) 0.00010W/MHz D1D, G1D 5.51~5.67GHz (40MHz spacing, 5 channels) 0.00004W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2024/10/09 [Name or Title] Mitsubishi Electric Mobility Corporation
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2023-03-14",
    "elecWave": "D1D,G1D 5.50~5.70GHz(20MHz間隔11波) 0.00010W/MHz\\nD1D,G1D 5.51~5.67GHz(40MHz間隔5波) 0.00004W/MHz",
    "fqMaintainFunc": "無",
    "name": "三菱電機株式会社",
    "note": "変更履歴は次のとおり。\\n・2024年10月09日に下記のとおり変更\\n【氏名又は名称】三菱電機モビリティ株式会社",
    "number": "005-100995",
    "organName": "テュフ・ラインランド・ジャパン(株)",
    "radioEquipmentCode": "第2条第19号の3の2に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "NR-213"
}

Radio record 6

Certification date
2015-05-27
Applicant
Mitsubishi Electric Corporation
Model / equipment
NR-213
Certifying organization
TUV Rheinland Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3, Section 2
Emission, frequency and power
D1D, G1D 5.50~5.70GHz (20MHz spacing, 11 channels) 0.00010W/MHz 5.51~5.67GHz (40MHz spacing, 5 channels) 0.00004W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
Notes
The change history is as follows. Changed as follows on 2024/10/09 [Name or Title] Mitsubishi Electric Mobility Corporation
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2015-05-27",
    "elecWave": "D1D, G1D\\n5.50~5.70GHz (20MHz間隔11波) 0.00010W/MHz\\n5.51~5.67GHz (40MHz間隔5波) 0.00004W/MHz",
    "fqMaintainFunc": "無",
    "name": "三菱電機株式会社",
    "note": "変更履歴は次のとおり。\\n・2024年10月09日に下記のとおり変更\\n【氏名又は名称】三菱電機モビリティ株式会社",
    "number": "005-100995",
    "organName": "テュフ・ラインランド・ジャパン(株)",
    "radioEquipmentCode": "第2条第19号の3の2に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "NR-213"
}

Photos and test report documents

No attachment documents are listed in this MIC record.