Giteki 007-AE0105

SX-PCEAC

MIC source updated 2026-10-19. English translations shown first; original Japanese fields are available on each certificate.

Certificate information

Certificate number
007-AE0105
Applicant
Silex Technology Inc.
Model / equipment
SX-PCEAC
Certification date
2017-06-23
Certifying organization
UL Japan Co., Ltd.
Certification year
2017

Radio equipment and technical records

Radio record 1

Certification date
2016-05-12
Applicant
Silex Technology Inc.
Model / equipment
SX-PCEAC
Certifying organization
UL Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
G1D D1D 5180~5240MHz (20MHz spacing, 4 channels) 0.001900W/MHz, 0.002200W/MHz G1D D1D 5190~5230MHz(40MHz spacing2 channels) 0.000900W/MHz G1D D1D 5210MHz 0.000590W/MHz G1D D1D 5260~5320MHz(20MHz spacing4 channels) 0.001900W/MHz G1D D1D 5270~5310MHz(40MHz spacing2 channels) 0.001150W/MHz G1D D1D 5290MHz 0.000445W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2016-05-12",
    "elecWave": "G1D D1D 5180~5240MHz(20MHz間隔4波) 0.001900W/MHz, 0.002200W/MHz\\nG1D D1D 5190~5230MHz(40MHz間隔2波) 0.000900W/MHz\\nG1D D1D 5210MHz 0.000590W/MHz\\nG1D D1D 5260~5320MHz(20MHz間隔4波) 0.001900W/MHz\\nG1D D1D 5270~5310MHz(40MHz間隔2波) 0.001150W/MHz\\nG1D D1D 5290MHz 0.000445W/MHz",
    "fqMaintainFunc": "無",
    "name": "サイレックス・テクノロジー株式会社",
    "note": "",
    "number": "007-AE0105",
    "organName": "(株)UL Japan",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "SX-PCEAC"
}

Radio record 2

Certification date
2017-06-23
Applicant
Silex Technology Inc.
Model / equipment
SX-PCEAC
Certifying organization
UL Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
G1D,D1D 5180~5240MHz(20MHz spacing4 channels) 0.001900,0.002200W/MHz G1D, D1D 5190~5230MHz (40MHz spacing, 2 channels) 0.000900W/MHz G1D,D1D 5.21GHz 0.000590W/MHz G1D, D1D 5260~5320MHz (20MHz spacing, 4 channels) 0.001900W/MHz G1D, D1D 5270~5310MHz (40MHz spacing, 2 channels) 0.001150W/MHz G1D,D1D 5.29GHz 0.000445W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2017-06-23",
    "elecWave": "G1D,D1D 5180~5240MHz(20MHz間隔4波) 0.001900,0.002200W/MHz\\nG1D,D1D 5190~5230MHz(40MHz間隔2波) 0.000900W/MHz\\nG1D,D1D 5.21GHz 0.000590W/MHz\\nG1D,D1D 5260~5320MHz(20MHz間隔4波) 0.001900W/MHz\\nG1D,D1D 5270~5310MHz(40MHz間隔2波) 0.001150W/MHz\\nG1D,D1D 5.29GHz 0.000445W/MHz",
    "fqMaintainFunc": "無",
    "name": "サイレックス・テクノロジー株式会社",
    "note": "",
    "number": "007-AE0105",
    "organName": "(株)UL Japan",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "SX-PCEAC"
}

Radio record 3

Certification date
2016-05-12
Applicant
Silex Technology Inc.
Model / equipment
SX-PCEAC
Certifying organization
UL Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3, Section 2
Emission, frequency and power
G1D D1D 5500~5700MHz(20MHz spacing11 channels) 0.003610W/MHz 0.004060W/MHz G1D D1D 5510~5670MHz(40MHz spacing5 channels) 0.002200W/MHz G1D D1D 5530~5610MHz(80MHz spacing2 channels) 0.001330W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2016-05-12",
    "elecWave": "G1D D1D 5500~5700MHz(20MHz間隔11波) 0.003610W/MHz\\n0.004060W/MHz\\nG1D D1D 5510~5670MHz(40MHz間隔5波) 0.002200W/MHz\\nG1D D1D 5530~5610MHz(80MHz間隔2波) 0.001330W/MHz",
    "fqMaintainFunc": "無",
    "name": "サイレックス・テクノロジー株式会社",
    "note": "",
    "number": "007-AE0105",
    "organName": "(株)UL Japan",
    "radioEquipmentCode": "第2条第19号の3の2に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "SX-PCEAC"
}

Radio record 4

Certification date
2017-06-23
Applicant
Silex Technology Inc.
Model / equipment
SX-PCEAC
Certifying organization
UL Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3, Section 2
Emission, frequency and power
G1D,D1D 5500~5700MHz(20MHz spacing11 channels) 0.003610,0.004060W/MHz G1D, D1D 5510~5670MHz (40MHz spacing, 5 channels) 0.002200W/MHz G1D, D1D 5530~5610MHz (80MHz spacing, 2 channels) 0.001330W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2017-06-23",
    "elecWave": "G1D,D1D 5500~5700MHz(20MHz間隔11波) 0.003610,0.004060W/MHz\\nG1D,D1D 5510~5670MHz(40MHz間隔5波) 0.002200W/MHz\\nG1D,D1D 5530~5610MHz(80MHz間隔2波) 0.001330W/MHz",
    "fqMaintainFunc": "無",
    "name": "サイレックス・テクノロジー株式会社",
    "note": "",
    "number": "007-AE0105",
    "organName": "(株)UL Japan",
    "radioEquipmentCode": "第2条第19号の3の2に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "SX-PCEAC"
}

Photos and test report documents

No attachment documents are listed in this MIC record.

Source: Japan Ministry of Internal Affairs and Communications (MIC). Giteki search · Search FCCID.io