Giteki 007-AG0048

1MW

MIC source updated 2026-10-19. English translations shown first; original Japanese fields are available on each certificate.

Certificate information

Certificate number
007-AG0048
Applicant
Murata Manufacturing Co., Ltd.
Model / equipment
1MW
Certification date
2026-02-10
Certifying organization
UL Japan Co., Ltd.
Certification year
2026

Radio equipment and technical records

Radio record 1

Certification date
2018-05-14
Applicant
Murata Manufacturing Co., Ltd.
Model / equipment
1MW
Certifying organization
UL Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19
Emission, frequency and power
G1D 2412~2472MHz (5MHz spacing, 13 channels) 0.010000W/MHz D1D,G1D 2412~2472MHz(5MHz spacing13 channels) 0.002254,0.001726W/MHz F1D 2402~2480MHz (1000kHz spacing, 79 channels) 0.000066~0.000234W/MHz G1D 2402~2480MHz (1000kHz spacing, 79 channels) 0.000027~0.000095W/MHz F1D 2402~2480MHz (2000kHz spacing, 40 channels) 0.003323W
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2018-05-14",
    "elecWave": "G1D 2412~2472MHz(5MHz間隔13波) 0.010000W/MHz\\nD1D,G1D 2412~2472MHz(5MHz間隔13波) 0.002254,0.001726W/MHz\\nF1D 2402~2480MHz(1000kHz間隔79波) 0.000066~0.000234W/MHz\\nG1D 2402~2480MHz(1000kHz間隔79波) 0.000027~0.000095W/MHz\\nF1D 2402~2480MHz(2000kHz間隔40波) 0.003323W",
    "fqMaintainFunc": "無",
    "name": "株式会社村田製作所",
    "note": "",
    "number": "007-AG0048",
    "organName": "(株)UL Japan",
    "radioEquipmentCode": "第2条第19号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "1MW"
}

Radio record 2

Certification date
2026-02-10
Applicant
Murata Manufacturing Co., Ltd.
Model / equipment
1MW
Certifying organization
UL Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19
Emission, frequency and power
G1D 2412~2472MHz (5MHz spacing, 13 channels) 0.010000W/MHz G1D,D1D 2412~2472MHz(5MHz spacing13 channels) 0.002254W/MHz,0.001726W/MHz F1D 2402~2480MHz (1000kHz spacing, 79 channels) 0.000066~0.000234W/MHz G1D 2402~2480MHz (1000kHz spacing, 79 channels) 0.000027~0.000095W/MHz F1D 2402~2480MHz (2000kHz spacing, 40 channels) 0.003323W
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2026-02-10",
    "elecWave": "G1D 2412~2472MHz(5MHz間隔13波) 0.010000W/MHz\\nG1D,D1D 2412~2472MHz(5MHz間隔13波) 0.002254W/MHz,0.001726W/MHz\\nF1D 2402~2480MHz(1000kHz間隔79波) 0.000066~0.000234W/MHz\\nG1D 2402~2480MHz(1000kHz間隔79波) 0.000027~0.000095W/MHz\\nF1D 2402~2480MHz(2000kHz間隔40波) 0.003323W",
    "fqMaintainFunc": "無",
    "name": "株式会社村田製作所",
    "note": "",
    "number": "007-AG0048",
    "organName": "(株)UL Japan",
    "radioEquipmentCode": "第2条第19号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "1MW"
}

Radio record 3

Certification date
2018-05-14
Applicant
Murata Manufacturing Co., Ltd.
Model / equipment
1MW
Certifying organization
UL Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
D1D,G1D 5180~5320MHz(20MHz spacing8 channels) 0.001425,0.001684W/MHz D1D, G1D 5190~5310MHz (40MHz spacing, 4 channels) 0.000479W/MHz D1D, G1D 5210~5290MHz (80MHz spacing, 2 channels) 0.000203W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2018-05-14",
    "elecWave": "D1D,G1D 5180~5320MHz(20MHz間隔8波) 0.001425,0.001684W/MHz\\nD1D,G1D 5190~5310MHz(40MHz間隔4波) 0.000479W/MHz\\nD1D,G1D 5210~5290MHz(80MHz間隔2波) 0.000203W/MHz",
    "fqMaintainFunc": "無",
    "name": "株式会社村田製作所",
    "note": "",
    "number": "007-AG0048",
    "organName": "(株)UL Japan",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "1MW"
}

Radio record 4

Certification date
2026-02-10
Applicant
Murata Manufacturing Co., Ltd.
Model / equipment
1MW
Certifying organization
UL Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
G1D,D1D 5.18~5.32GHz(20MHz spacing8 channels) 0.001425W/MHz,0.001684W/MHz G1D, D1D 5.19~5.31GHz (40MHz spacing, 4 channels) 0.000479W/MHz G1D,D1D 5.21GHz,5.29GHz 0.000203W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2026-02-10",
    "elecWave": "G1D,D1D 5.18~5.32GHz(20MHz間隔8波) 0.001425W/MHz,0.001684W/MHz\\nG1D,D1D 5.19~5.31GHz(40MHz間隔4波) 0.000479W/MHz\\nG1D,D1D 5.21GHz,5.29GHz 0.000203W/MHz",
    "fqMaintainFunc": "無",
    "name": "株式会社村田製作所",
    "note": "",
    "number": "007-AG0048",
    "organName": "(株)UL Japan",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "1MW"
}

Radio record 5

Certification date
2018-05-14
Applicant
Murata Manufacturing Co., Ltd.
Model / equipment
1MW
Certifying organization
UL Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3, Section 2
Emission, frequency and power
D1D,G1D 5500~5700MHz(20MHz spacing11 channels) 0.00029~0.000998,0.00023~0.001179W/MHz D1D, G1D 5510~5670MHz (40MHz spacing, 5 channels) 0.00015~0.000335W/MHz D1D, G1D 5530~5610MHz (80MHz spacing, 2 channels) 0.00008~0.000142W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2018-05-14",
    "elecWave": "D1D,G1D 5500~5700MHz(20MHz間隔11波) 0.00029~0.000998,0.00023~0.001179W/MHz\\nD1D,G1D 5510~5670MHz(40MHz間隔5波) 0.00015~0.000335W/MHz\\nD1D,G1D 5530~5610MHz(80MHz間隔2波) 0.00008~0.000142W/MHz",
    "fqMaintainFunc": "無",
    "name": "株式会社村田製作所",
    "note": "",
    "number": "007-AG0048",
    "organName": "(株)UL Japan",
    "radioEquipmentCode": "第2条第19号の3の2に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "1MW"
}

Radio record 6

Certification date
2026-02-10
Applicant
Murata Manufacturing Co., Ltd.
Model / equipment
1MW
Certifying organization
UL Japan Co., Ltd.
Certification type
Construction design certification by a registered certification body
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3, Section 2
Emission, frequency and power
G1D,D1D 5.50~5.70GHz(20MHz spacing11 channels) 0.00029~0.000998W/MHz,0.00023~0.001179W/MHz G1D, D1D 5.51~5.67GHz (40MHz spacing, 5 channels) 0.00015~0.000335W/MHz G1D,D1D 5.53GHz,5.61GHz 0.00008~0.000142W/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2026-02-10",
    "elecWave": "G1D,D1D 5.50~5.70GHz(20MHz間隔11波) 0.00029~0.000998W/MHz,0.00023~0.001179W/MHz\\nG1D,D1D 5.51~5.67GHz(40MHz間隔5波) 0.00015~0.000335W/MHz\\nG1D,D1D 5.53GHz,5.61GHz 0.00008~0.000142W/MHz",
    "fqMaintainFunc": "無",
    "name": "株式会社村田製作所",
    "note": "",
    "number": "007-AG0048",
    "organName": "(株)UL Japan",
    "radioEquipmentCode": "第2条第19号の3の2に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "登録証明機関による工事設計認証",
    "typeName": "1MW"
}

Photos and test report documents

No attachment documents are listed in this MIC record.

Source: Japan Ministry of Internal Affairs and Communications (MIC). Giteki search · Search FCCID.io