Giteki 201-135334

Skorpio X3

MIC source updated 2026-10-19. English translations shown first; original Japanese fields are available on each certificate.

Certificate information

Certificate number
201-135334
Applicant
Datalogic ADC S.R.L | Datalogic S.R.L.
Model / equipment
Skorpio X3
Certification date
2017-05-15
Certifying organization
Kiwa Nederland B.V.
Certification year
2017

Radio equipment and technical records

Radio record 1

Certification date
2013-09-06
Applicant
Datalogic ADC S.R.L
Model / equipment
Skorpio X3
Certifying organization
Kiwa Nederland B.V.
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19
Emission, frequency and power
15M8G1D 2412-2472MHz(13channels) 4.74mW\/MHz 17M4D1D 2412-2472MHz(13channels) 2.89mW\/MHz 77M7F1D 2402-2480MHz(79channels) 0.2mW\/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2013-09-06",
    "elecWave": "15M8G1D 2412-2472MHz(13channels) 4.74mW\\/MHz\\n17M4D1D 2412-2472MHz(13channels) 2.89mW\\/MHz\\n77M7F1D 2402-2480MHz(79channels) 0.2mW\\/MHz",
    "fqMaintainFunc": "無",
    "name": "Datalogic ADC S.R.L",
    "note": "",
    "number": "201-135334",
    "organName": "Kiwa Nederland B.V.",
    "radioEquipmentCode": "第2条第19号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "Skorpio X3"
}

Radio record 2

Certification date
2013-09-06
Applicant
Datalogic ADC S.R.L
Model / equipment
Skorpio X3
Certifying organization
Kiwa Nederland B.V.
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 2
Emission, frequency and power
19M7G1D 2484MHz(1channel) 4.05mW\/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2013-09-06",
    "elecWave": "19M7G1D 2484MHz(1channel) 4.05mW\\/MHz",
    "fqMaintainFunc": "無",
    "name": "Datalogic ADC S.R.L",
    "note": "",
    "number": "201-135334",
    "organName": "Kiwa Nederland B.V.",
    "radioEquipmentCode": "第2条第19号の2に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "Skorpio X3"
}

Radio record 3

Certification date
2013-09-06
Applicant
Datalogic ADC S.R.L
Model / equipment
Skorpio X3
Certifying organization
Kiwa Nederland B.V.
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
16M8D1D 5180-5320MHz(8channels) 1.52mW\/MHZ
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2013-09-06",
    "elecWave": "16M8D1D 5180-5320MHz(8channels) 1.52mW\\/MHZ",
    "fqMaintainFunc": "無",
    "name": "Datalogic ADC S.R.L",
    "note": "",
    "number": "201-135334",
    "organName": "Kiwa Nederland B.V.",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "Skorpio X3"
}

Radio record 4

Certification date
2017-05-15
Applicant
Datalogic S.R.L.
Model / equipment
Skorpio X3
Certifying organization
Kiwa Nederland B.V.
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19
Emission, frequency and power
15M8 G1D 2412~2472MHz(13Ch) 4.74mW/MHz 17M4 D1D 2412~2472MHz(13Ch) 2.89mW/MHz 77M7 F1D 2402~2480MHz(79Ch) 0.2mW/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2017-05-15",
    "elecWave": "15M8 G1D 2412~2472MHz(13Ch) 4.74mW/MHz\\n17M4 D1D 2412~2472MHz(13Ch) 2.89mW/MHz\\n77M7 F1D 2402~2480MHz(79Ch) 0.2mW/MHz",
    "fqMaintainFunc": "無",
    "name": "Datalogic S.R.L.",
    "note": "",
    "number": "201-135334",
    "organName": "Kiwa Nederland B.V.",
    "radioEquipmentCode": "第2条第19号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "Skorpio X3"
}

Radio record 5

Certification date
2017-05-15
Applicant
Datalogic S.R.L.
Model / equipment
Skorpio X3
Certifying organization
Kiwa Nederland B.V.
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 2
Emission, frequency and power
19M7 G1D 2484MHz 4.05mW/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2017-05-15",
    "elecWave": "19M7 G1D 2484MHz 4.05mW/MHz",
    "fqMaintainFunc": "無",
    "name": "Datalogic S.R.L.",
    "note": "",
    "number": "201-135334",
    "organName": "Kiwa Nederland B.V.",
    "radioEquipmentCode": "第2条第19号の2に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "Skorpio X3"
}

Radio record 6

Certification date
2017-05-15
Applicant
Datalogic S.R.L.
Model / equipment
Skorpio X3
Certifying organization
Kiwa Nederland B.V.
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
16M8 D1D 5180~5320MHz(8Ch) 1.52mW/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2017-05-15",
    "elecWave": "16M8 D1D 5180~5320MHz(8Ch) 1.52mW/MHz",
    "fqMaintainFunc": "無",
    "name": "Datalogic S.R.L.",
    "note": "",
    "number": "201-135334",
    "organName": "Kiwa Nederland B.V.",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "Skorpio X3"
}

Photos and test report documents

No attachment documents are listed in this MIC record.

Source: Japan Ministry of Internal Affairs and Communications (MIC). Giteki search · Search FCCID.io