UBB-XG — Giteki 201-230819

This MIC record lists UBB-XG with applicant Ubiquiti Inc. under Giteki number 201-230819.

Catalog checked against MIC data dated 2026-10-20. English translations shown first; original Japanese fields are available on each certificate.

Certificate information

Certificate number
201-230819
Applicant
Ubiquiti Inc.
Model / equipment
UBB-XG
Certification date
2023-12-28
Certifying organization
Kiwa Nederland B.V.
Certification year
2023

Radio equipment and technical records

Radio record 1

Certification date
2023-12-28
Applicant
Ubiquiti Inc.
Model / equipment
UBB-XG
Certifying organization
Kiwa Nederland B.V.
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19
Emission, frequency and power
F1D 2402~2480MHz(40Ch) 6mW
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "2",
    "attachmentFileCntForCd2": "4",
    "attachmentFileKey": "201_N_1_240328N201_%E8%AA%8D%E8%A8%BC_28_*****_*****",
    "attachmentFileName": "201-230819_01_001.pdf\\n201-230819_01_002.pdf\\n201-230819_02_003.pdf\\n201-230819_02_004.pdf\\n201-230819_02_005.pdf\\n201-230819_02_006.pdf",
    "bodySar": "―",
    "date": "2023-12-28",
    "elecWave": "F1D 2402~2480MHz(40Ch) 6mW",
    "fqMaintainFunc": "無",
    "name": "Ubiquiti Inc.",
    "note": "",
    "number": "201-230819",
    "organName": "Kiwa Nederland B.V.",
    "radioEquipmentCode": "第2条第19号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "UBB-XG"
}

Radio record 2

Certification date
2023-12-28
Applicant
Ubiquiti Inc.
Model / equipment
UBB-XG
Certifying organization
Kiwa Nederland B.V.
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
D1D,G1D 5500~5700MHz(11Ch) 2mW/MHz D1D,G1D 5510~5670MHz(5Ch) 0.99mW/MHz D1D,G1D 5530~5610MHz(2Ch) 0.495mW/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2023-12-28",
    "elecWave": "D1D,G1D 5500~5700MHz(11Ch) 2mW/MHz\\nD1D,G1D 5510~5670MHz(5Ch) 0.99mW/MHz\\nD1D,G1D 5530~5610MHz(2Ch) 0.495mW/MHz",
    "fqMaintainFunc": "無",
    "name": "Ubiquiti Inc.",
    "note": "",
    "number": "201-230819",
    "organName": "Kiwa Nederland B.V.",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "UBB-XG"
}

Radio record 3

Certification date
2023-12-28
Applicant
Ubiquiti Inc.
Model / equipment
UBB-XG
Certifying organization
Kiwa Nederland B.V.
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 4, Section 2
Emission, frequency and power
N0N 58320~63720MHz(7Ch) 62mW
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2023-12-28",
    "elecWave": "N0N 58320~63720MHz(7Ch) 62mW",
    "fqMaintainFunc": "無",
    "name": "Ubiquiti Inc.",
    "note": "",
    "number": "201-230819",
    "organName": "Kiwa Nederland B.V.",
    "radioEquipmentCode": "第2条第19号の4の2に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "UBB-XG"
}

Photos and test report documents

Source: Japan Ministry of Internal Affairs and Communications (MIC). Giteki search · Search FCCID.io