Giteki 210-127544

Secure Server Router [003-170295]

MIC source updated 2026-10-20. English translations shown first; original Japanese fields are available on each certificate.

Certificate information

Certificate number
210-127544
Applicant
Rockwell Collins
Model / equipment
Secure Server Router [003-170295]
Certification date
2019-04-01
Certifying organization
MiCOM Labs
Certification year
2019

Radio equipment and technical records

Radio record 1

Certification date
2019-04-01
Applicant
Rockwell Collins
Model / equipment
Secure Server Router [003-170295]
Certifying organization
MiCOM Labs
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 11, Subitem 3
Emission, frequency and power
5M00 G1A,G1B,G1C,G1D,G1F,G1X,G7W 832.4~842.6MHz(200kHz spacing 52 channels),832.5,837.5,842.5MHz,902.6~912.4MHz(200kHz spacing 50 channels),1747.4~1782.4MHz(200kHz spacing 176 channels),1922.6~1977.4MHz(200kHz spacing 275 channels) 24dBm
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2019-04-01",
    "elecWave": "5M00 G1A,G1B,G1C,G1D,G1F,G1X,G7W 832.4~842.6MHz(200kHz間隔52波),832.5,837.5,842.5MHz,902.6~912.4MHz(200kHz間隔50波),1747.4~1782.4MHz(200kHz間隔176波),1922.6~1977.4MHz(200kHz間隔275波) 24dBm",
    "fqMaintainFunc": "無",
    "name": "Rockwell Collins",
    "note": "",
    "number": "210-127544",
    "organName": "MiCOM Labs",
    "radioEquipmentCode": "第2条第11号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "Secure Server Router [003-170295]"
}

Radio record 2

Certification date
2019-04-01
Applicant
Rockwell Collins
Model / equipment
Secure Server Router [003-170295]
Certifying organization
MiCOM Labs
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 11, Subitem 7
Emission, frequency and power
5M00 G1A,G1B,G1C,G1D,G1F,G1X,G7W 832.4~842.6MHz(200kHz spacing 52 channels),832.5,837.5,842.5MHz,902.6~912.4MHz(200kHz spacing 50 channels),1747.4~1782.4MHz(200kHz spacing 176 channels),1922.6~1977.4MHz(200kHz spacing 275 channels) 24dBm
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2019-04-01",
    "elecWave": "5M00 G1A,G1B,G1C,G1D,G1F,G1X,G7W 832.4~842.6MHz(200kHz間隔52波),832.5,837.5,842.5MHz,902.6~912.4MHz(200kHz間隔50波),1747.4~1782.4MHz(200kHz間隔176波),1922.6~1977.4MHz(200kHz間隔275波) 24dBm",
    "fqMaintainFunc": "無",
    "name": "Rockwell Collins",
    "note": "",
    "number": "210-127544",
    "organName": "MiCOM Labs",
    "radioEquipmentCode": "第2条第11号の7に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "Secure Server Router [003-170295]"
}

Radio record 3

Certification date
2019-04-01
Applicant
Rockwell Collins
Model / equipment
Secure Server Router [003-170295]
Certifying organization
MiCOM Labs
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 11, Subitem 19
Emission, frequency and power
5M00 D1A, D1B, D1C, D1D, D1F, D1X, D7W, G1A, G1B, G1C, G1D, G1F, G1X, G7W 720.5~745.5MHz (100kHz spacing, 251 channels), 817.5~842.5MHz (100kHz spacing, 251 channels), 902.5~912.5MHz (100kHz spacing, 101 channels), 1712.5~1782.5MHz (100kHz spacing, 701 channels), 1927.2~1977.5MHz (100kHz spacing, 504 channels) 0.2W 10M0 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 723.0~743.0MHz(100kHz spacing201 channels),820.0~840.0MHz(100kHz spacing201 channels),910MHzFrequency whiCh can be simultaneous transmission is the continuous maximum 5.76MHz width between 906.22MHz-914.50MHz,1715.0~1780.0MHz(100kHz spacing651 channels),1934.7~1975.0MHz(100kHz spacing404 channels) 0.2W 15M0 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 725.5~740.5MHz(100kHz spacing151 channels),822.5~837.5MHz(100kHz spacing151 channels),1717.5~1777.5MHz(100kHz spacing601 channels),1942.2~1972.5MHz(100kHz spacing304 channels) 0.2W 15M0 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 1932.5MHz 0.016~0.2W 20M0 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 728.0~738.0MHz(100kHz spacing101 channels),1720.0~1775.0MHz(100kHz spacing551 channels),1949.7~1970.0MHz(100kHz spacing204 channels) 0.2W 20M0 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 1930MHz 0.016~0.2W
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2019-04-01",
    "elecWave": "5M00 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 720.5~745.5MHz(100kHz間隔251波),817.5~842.5MHz(100kHz間隔251波),902.5~912.5MHz(100kHz間隔101波),1712.5~1782.5MHz(100kHz間隔701波),1927.2~1977.5MHz(100kHz間隔504波) 0.2W\\n10M0 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 723.0~743.0MHz(100kHz間隔201波),820.0~840.0MHz(100kHz間隔201波),910MHzFrequency whiCh can be simultaneous transmission is the continuous maximum 5.76MHz width between 906.22MHz-914.50MHz,1715.0~1780.0MHz(100kHz間隔651波),1934.7~1975.0MHz(100kHz間隔404波) 0.2W\\n15M0 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 725.5~740.5MHz(100kHz間隔151波),822.5~837.5MHz(100kHz間隔151波),1717.5~1777.5MHz(100kHz間隔601波),1942.2~1972.5MHz(100kHz間隔304波) 0.2W\\n15M0 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 1932.5MHz 0.016~0.2W\\n20M0 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 728.0~738.0MHz(100kHz間隔101波),1720.0~1775.0MHz(100kHz間隔551波),1949.7~1970.0MHz(100kHz間隔204波) 0.2W\\n20M0 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 1930MHz 0.016~0.2W",
    "fqMaintainFunc": "無",
    "name": "Rockwell Collins",
    "note": "",
    "number": "210-127544",
    "organName": "MiCOM Labs",
    "radioEquipmentCode": "第2条第11号の19に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "Secure Server Router [003-170295]"
}

Radio record 4

Certification date
2019-04-01
Applicant
Rockwell Collins
Model / equipment
Secure Server Router [003-170295]
Certifying organization
MiCOM Labs
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 11, Subitem 21
Emission, frequency and power
5M00 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 3402.5~3597.5MHz(100kHz spacing1951 channels) 0.2W 10M0 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 3405.0~3595.0MHz(100kHz spacing1901 channels) 0.2W 15M0 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 3407.5~3592.5MHz(100kHz spacing1851 channels) 0.2W 20M0 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 3410.0~3590.0MHz(100kHz spacing1801 channels) 0.2W
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2019-04-01",
    "elecWave": "5M00 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 3402.5~3597.5MHz(100kHz間隔1951波) 0.2W\\n10M0 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 3405.0~3595.0MHz(100kHz間隔1901波) 0.2W\\n15M0 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 3407.5~3592.5MHz(100kHz間隔1851波) 0.2W\\n20M0 D1A,D1B,D1C,D1D,D1F,D1X,D7W,G1A,G1B,G1C,G1D,G1F,G1X,G7W 3410.0~3590.0MHz(100kHz間隔1801波) 0.2W",
    "fqMaintainFunc": "無",
    "name": "Rockwell Collins",
    "note": "",
    "number": "210-127544",
    "organName": "MiCOM Labs",
    "radioEquipmentCode": "第2条第11号の21に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "Secure Server Router [003-170295]"
}

Radio record 5

Certification date
2019-04-01
Applicant
Rockwell Collins
Model / equipment
Secure Server Router [003-170295]
Certifying organization
MiCOM Labs
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19
Emission, frequency and power
14M0 G1D 2412~2472MHz 0.53mW/MHz 16M7 D1D 2412~2472MHz 0.05mW/MHz 18M0 D1D 2412~2472MHz 0.49mW/MHz 37M2 D1D 2422~2462MHz 0.60mW/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2019-04-01",
    "elecWave": "14M0 G1D 2412~2472MHz 0.53mW/MHz\\n16M7 D1D 2412~2472MHz 0.05mW/MHz\\n18M0 D1D 2412~2472MHz 0.49mW/MHz\\n37M2 D1D 2422~2462MHz 0.60mW/MHz",
    "fqMaintainFunc": "無",
    "name": "Rockwell Collins",
    "note": "",
    "number": "210-127544",
    "organName": "MiCOM Labs",
    "radioEquipmentCode": "第2条第19号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "Secure Server Router [003-170295]"
}

Radio record 6

Certification date
2019-04-01
Applicant
Rockwell Collins
Model / equipment
Secure Server Router [003-170295]
Certifying organization
MiCOM Labs
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
16M5 D1D 5180~5240MHz 0.13mW/MHz 17M7 D1D 5180~5240MHz 0.02mW/MHz 37M0 D1D 5190~5230MHz 0.05mW/MHz 76M0 D1D 5210~5210MHz 0.07mW/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2019-04-01",
    "elecWave": "16M5 D1D 5180~5240MHz 0.13mW/MHz\\n17M7 D1D 5180~5240MHz 0.02mW/MHz\\n37M0 D1D 5190~5230MHz 0.05mW/MHz\\n76M0 D1D 5210~5210MHz 0.07mW/MHz",
    "fqMaintainFunc": "無",
    "name": "Rockwell Collins",
    "note": "",
    "number": "210-127544",
    "organName": "MiCOM Labs",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "Secure Server Router [003-170295]"
}

Radio record 7

Certification date
2019-04-01
Applicant
Rockwell Collins
Model / equipment
Secure Server Router [003-170295]
Certifying organization
MiCOM Labs
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 54
Emission, frequency and power
5M00 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2547.5~2652.5MHz(100kHz spacing1051 channels) 0.2W 10M0 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2550~2650MHz(100kHz spacing1001 channels) 0.2W 20M0 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2555~2645MHz(100kHz spacing901 channels) 0.2W 29M9 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2610.25MHz 0.2W 39M8 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2625.1MHz 0.2W
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2019-04-01",
    "elecWave": "5M00 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2547.5~2652.5MHz(100kHz間隔1051波) 0.2W\\n10M0 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2550~2650MHz(100kHz間隔1001波) 0.2W\\n20M0 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2555~2645MHz(100kHz間隔901波) 0.2W\\n29M9 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2610.25MHz 0.2W\\n39M8 X1A,X1B,X1C,X1D,X1F,X1X,X7W 2625.1MHz 0.2W",
    "fqMaintainFunc": "無",
    "name": "Rockwell Collins",
    "note": "",
    "number": "210-127544",
    "organName": "MiCOM Labs",
    "radioEquipmentCode": "第2条第54号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "Secure Server Router [003-170295]"
}

Photos and test report documents

No attachment documents are listed in this MIC record.

Source: Japan Ministry of Internal Affairs and Communications (MIC). Giteki search · Search FCCID.io