Giteki 210-137132

Smart Double Screen Translator [KI-8113]

MIC source updated 2026-10-19. English translations shown first; original Japanese fields are available on each certificate.

Certificate information

Certificate number
210-137132
Applicant
Union Electronics Industrial Co., Ltd
Model / equipment
Smart Double Screen Translator [KI-8113]
Certification date
2020-01-19
Certifying organization
MiCOM Labs
Certification year
2020

Radio equipment and technical records

Radio record 1

Certification date
2020-01-19
Applicant
Union Electronics Industrial Co., Ltd
Model / equipment
Smart Double Screen Translator [KI-8113]
Certifying organization
MiCOM Labs
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19
Emission, frequency and power
78M1 F1D 2402~2480MHz 0.05mW/MHz 78M2 G1D 2402~2480MHz 0.02mW/MHz 1M06 F1D 2402~2480MHz 1.5mW 12M0 G1D 2412~2472MHz 3.0mW/MHz 16M9 D1D 2412~2472MHz 1.3mW/MHz 18M0 D1D 2412~2472MHz 1.1mW/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "2",
    "attachmentFileCntForCd2": "5",
    "attachmentFileKey": "210_N_1_200129N210_%E8%AA%8D%E8%A8%BC_8_*****_*****",
    "attachmentFileName": "210-137132_01_002.pdf\\n210-137132_01_003.pdf\\n210-137132_02_004.pdf\\n210-137132_02_005.pdf\\n210-137132_02_006.pdf\\n210-137132_02_007.pdf\\n210-137132_02_008.pdf",
    "bodySar": "―",
    "date": "2020-01-19",
    "elecWave": "78M1 F1D 2402~2480MHz 0.05mW/MHz\\n78M2 G1D 2402~2480MHz 0.02mW/MHz\\n1M06 F1D 2402~2480MHz 1.5mW\\n12M0 G1D 2412~2472MHz 3.0mW/MHz\\n16M9 D1D 2412~2472MHz 1.3mW/MHz\\n18M0 D1D 2412~2472MHz 1.1mW/MHz",
    "fqMaintainFunc": "無",
    "name": "Union Electronics Industrial Co., Ltd",
    "note": "",
    "number": "210-137132",
    "organName": "MiCOM Labs",
    "radioEquipmentCode": "第2条第19号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "Smart Double Screen Translator [KI-8113]"
}

Radio record 2

Certification date
2020-01-19
Applicant
Union Electronics Industrial Co., Ltd
Model / equipment
Smart Double Screen Translator [KI-8113]
Certifying organization
MiCOM Labs
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
16M6 D1D 5180~5240MHz 0.7mW/MHz 17M7 D1D 5180~5240MHz 0.7mW/MHz 17M7 D1D 5180~5240MHz 0.7mW/MHz 36M0 D1D 5190~5230MHz 0.4mW/MHz 35M9 D1D 5190~5230MHz 0.4mW/MHz 75M2 D1D 5210~5210MHz 0.2mW/MHz 16M6 D1D 5260~5320MHz 0.7mW/MHz 17M7 D1D 5260~5320MHz 0.7mW/MHz 17M8 D1D 5260~5320MHz 0.7mW/MHz 36M0 D1D 5270~5310MHz 0.4mW/MHz 36M0 D1D 5270~5310MHz 0.4mW/MHz 75M8 D1D 5290~5290MHz 0.2mW/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2020-01-19",
    "elecWave": "16M6 D1D 5180~5240MHz 0.7mW/MHz\\n17M7 D1D 5180~5240MHz 0.7mW/MHz\\n17M7 D1D 5180~5240MHz 0.7mW/MHz\\n36M0 D1D 5190~5230MHz 0.4mW/MHz\\n35M9 D1D 5190~5230MHz 0.4mW/MHz\\n75M2 D1D 5210~5210MHz 0.2mW/MHz\\n16M6 D1D 5260~5320MHz 0.7mW/MHz\\n17M7 D1D 5260~5320MHz 0.7mW/MHz\\n17M8 D1D 5260~5320MHz 0.7mW/MHz\\n36M0 D1D 5270~5310MHz 0.4mW/MHz\\n36M0 D1D 5270~5310MHz 0.4mW/MHz\\n75M8 D1D 5290~5290MHz 0.2mW/MHz",
    "fqMaintainFunc": "無",
    "name": "Union Electronics Industrial Co., Ltd",
    "note": "",
    "number": "210-137132",
    "organName": "MiCOM Labs",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "Smart Double Screen Translator [KI-8113]"
}

Radio record 3

Certification date
2020-01-19
Applicant
Union Electronics Industrial Co., Ltd
Model / equipment
Smart Double Screen Translator [KI-8113]
Certifying organization
MiCOM Labs
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3, Section 2
Emission, frequency and power
16M6 D1D 5500~5700MHz 0.7mW/MHz 17M7 D1D 5500~5700MHz 0.7mW/MHz 17M8 D1D 5500~5700MHz 0.7mW/MHz 36M0 D1D 5510~5670MHz 0.4mW/MHz 36M0 D1D 5510~5670MHz 0.4mW/MHz 75M6 D1D 5530~5610MHz 0.2mW/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "―",
    "date": "2020-01-19",
    "elecWave": "16M6 D1D 5500~5700MHz 0.7mW/MHz\\n17M7 D1D 5500~5700MHz 0.7mW/MHz\\n17M8 D1D 5500~5700MHz 0.7mW/MHz\\n36M0 D1D 5510~5670MHz 0.4mW/MHz\\n36M0 D1D 5510~5670MHz 0.4mW/MHz\\n75M6 D1D 5530~5610MHz 0.2mW/MHz",
    "fqMaintainFunc": "無",
    "name": "Union Electronics Industrial Co., Ltd",
    "note": "",
    "number": "210-137132",
    "organName": "MiCOM Labs",
    "radioEquipmentCode": "第2条第19号の3の2に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "Smart Double Screen Translator [KI-8113]"
}

Photos and test report documents

Source: Japan Ministry of Internal Affairs and Communications (MIC). Giteki search · Search FCCID.io