- FCC ID1
- Japan Giteki2
- 210-1371323
Giteki 210-137132
Smart Double Screen Translator [KI-8113]
MIC source updated 2026-10-19. English translations shown first; original Japanese fields are available on each certificate.
Certificate information
- Certificate number
- 210-137132
- Applicant
- Union Electronics Industrial Co., Ltd
- Model / equipment
- Smart Double Screen Translator [KI-8113]
- Certification date
- 2020-01-19
- Certifying organization
- MiCOM Labs
- Certification year
- 2020
Radio equipment and technical records
Radio record 1
- Certification date
- 2020-01-19
- Applicant
- Union Electronics Industrial Co., Ltd
- Model / equipment
- Smart Double Screen Translator [KI-8113]
- Certifying organization
- MiCOM Labs
- Certification type
- Construction design certification under mutual recognition (MRA)
- Radio equipment class
- Specific radio equipment specified in Article 2, Item 19
- Emission, frequency and power
- 78M1 F1D 2402~2480MHz 0.05mW/MHz
78M2 G1D 2402~2480MHz 0.02mW/MHz
1M06 F1D 2402~2480MHz 1.5mW
12M0 G1D 2412~2472MHz 3.0mW/MHz
16M9 D1D 2412~2472MHz 1.3mW/MHz
18M0 D1D 2412~2472MHz 1.1mW/MHz
- Body SAR
- ―
- Frequency maintenance function
- No
- Spurious emission rules
- New spurious emission rules
All original source fields
{
"attachmentFileCntForCd1": "2",
"attachmentFileCntForCd2": "5",
"attachmentFileKey": "210_N_1_200129N210_%E8%AA%8D%E8%A8%BC_8_*****_*****",
"attachmentFileName": "210-137132_01_002.pdf\\n210-137132_01_003.pdf\\n210-137132_02_004.pdf\\n210-137132_02_005.pdf\\n210-137132_02_006.pdf\\n210-137132_02_007.pdf\\n210-137132_02_008.pdf",
"bodySar": "―",
"date": "2020-01-19",
"elecWave": "78M1 F1D 2402~2480MHz 0.05mW/MHz\\n78M2 G1D 2402~2480MHz 0.02mW/MHz\\n1M06 F1D 2402~2480MHz 1.5mW\\n12M0 G1D 2412~2472MHz 3.0mW/MHz\\n16M9 D1D 2412~2472MHz 1.3mW/MHz\\n18M0 D1D 2412~2472MHz 1.1mW/MHz",
"fqMaintainFunc": "無",
"name": "Union Electronics Industrial Co., Ltd",
"note": "",
"number": "210-137132",
"organName": "MiCOM Labs",
"radioEquipmentCode": "第2条第19号に規定する特定無線設備",
"spuriousRules": "新スプリアス規定",
"techCode": "相互承認(MRA)による工事設計認証",
"typeName": "Smart Double Screen Translator [KI-8113]"
}
Radio record 2
- Certification date
- 2020-01-19
- Applicant
- Union Electronics Industrial Co., Ltd
- Model / equipment
- Smart Double Screen Translator [KI-8113]
- Certifying organization
- MiCOM Labs
- Certification type
- Construction design certification under mutual recognition (MRA)
- Radio equipment class
- Specific radio equipment specified in Article 2, Item 19, Subitem 3
- Emission, frequency and power
- 16M6 D1D 5180~5240MHz 0.7mW/MHz
17M7 D1D 5180~5240MHz 0.7mW/MHz
17M7 D1D 5180~5240MHz 0.7mW/MHz
36M0 D1D 5190~5230MHz 0.4mW/MHz
35M9 D1D 5190~5230MHz 0.4mW/MHz
75M2 D1D 5210~5210MHz 0.2mW/MHz
16M6 D1D 5260~5320MHz 0.7mW/MHz
17M7 D1D 5260~5320MHz 0.7mW/MHz
17M8 D1D 5260~5320MHz 0.7mW/MHz
36M0 D1D 5270~5310MHz 0.4mW/MHz
36M0 D1D 5270~5310MHz 0.4mW/MHz
75M8 D1D 5290~5290MHz 0.2mW/MHz
- Body SAR
- ―
- Frequency maintenance function
- No
- Spurious emission rules
- New spurious emission rules
All original source fields
{
"attachmentFileCntForCd1": "",
"attachmentFileCntForCd2": "",
"attachmentFileKey": "",
"attachmentFileName": "",
"bodySar": "―",
"date": "2020-01-19",
"elecWave": "16M6 D1D 5180~5240MHz 0.7mW/MHz\\n17M7 D1D 5180~5240MHz 0.7mW/MHz\\n17M7 D1D 5180~5240MHz 0.7mW/MHz\\n36M0 D1D 5190~5230MHz 0.4mW/MHz\\n35M9 D1D 5190~5230MHz 0.4mW/MHz\\n75M2 D1D 5210~5210MHz 0.2mW/MHz\\n16M6 D1D 5260~5320MHz 0.7mW/MHz\\n17M7 D1D 5260~5320MHz 0.7mW/MHz\\n17M8 D1D 5260~5320MHz 0.7mW/MHz\\n36M0 D1D 5270~5310MHz 0.4mW/MHz\\n36M0 D1D 5270~5310MHz 0.4mW/MHz\\n75M8 D1D 5290~5290MHz 0.2mW/MHz",
"fqMaintainFunc": "無",
"name": "Union Electronics Industrial Co., Ltd",
"note": "",
"number": "210-137132",
"organName": "MiCOM Labs",
"radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
"spuriousRules": "新スプリアス規定",
"techCode": "相互承認(MRA)による工事設計認証",
"typeName": "Smart Double Screen Translator [KI-8113]"
}
Radio record 3
- Certification date
- 2020-01-19
- Applicant
- Union Electronics Industrial Co., Ltd
- Model / equipment
- Smart Double Screen Translator [KI-8113]
- Certifying organization
- MiCOM Labs
- Certification type
- Construction design certification under mutual recognition (MRA)
- Radio equipment class
- Specific radio equipment specified in Article 2, Item 19, Subitem 3, Section 2
- Emission, frequency and power
- 16M6 D1D 5500~5700MHz 0.7mW/MHz
17M7 D1D 5500~5700MHz 0.7mW/MHz
17M8 D1D 5500~5700MHz 0.7mW/MHz
36M0 D1D 5510~5670MHz 0.4mW/MHz
36M0 D1D 5510~5670MHz 0.4mW/MHz
75M6 D1D 5530~5610MHz 0.2mW/MHz
- Body SAR
- ―
- Frequency maintenance function
- No
- Spurious emission rules
- New spurious emission rules
All original source fields
{
"attachmentFileCntForCd1": "",
"attachmentFileCntForCd2": "",
"attachmentFileKey": "",
"attachmentFileName": "",
"bodySar": "―",
"date": "2020-01-19",
"elecWave": "16M6 D1D 5500~5700MHz 0.7mW/MHz\\n17M7 D1D 5500~5700MHz 0.7mW/MHz\\n17M8 D1D 5500~5700MHz 0.7mW/MHz\\n36M0 D1D 5510~5670MHz 0.4mW/MHz\\n36M0 D1D 5510~5670MHz 0.4mW/MHz\\n75M6 D1D 5530~5610MHz 0.2mW/MHz",
"fqMaintainFunc": "無",
"name": "Union Electronics Industrial Co., Ltd",
"note": "",
"number": "210-137132",
"organName": "MiCOM Labs",
"radioEquipmentCode": "第2条第19号の3の2に規定する特定無線設備",
"spuriousRules": "新スプリアス規定",
"techCode": "相互承認(MRA)による工事設計認証",
"typeName": "Smart Double Screen Translator [KI-8113]"
}
Photos and test report documents