Giteki 210-203156

DTEN D7X 75= [DB71475, DB71475-S1]

MIC source updated 2026-10-20. English translations shown first; original Japanese fields are available on each certificate.

Certificate information

Certificate number
210-203156
Applicant
DTEN Inc
Model / equipment
DTEN D7X 75= [DB71475, DB71475-S1]
Certification date
2022-12-23
Certifying organization
MiCOM Labs
Certification year
2022

Radio equipment and technical records

Radio record 1

Certification date
2022-12-23
Applicant
DTEN Inc
Model / equipment
DTEN D7X 75= [DB71475, DB71475-S1]
Certifying organization
MiCOM Labs
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 8
Emission, frequency and power
200MF1D 24050~24250MHz 6.4mW
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "2",
    "attachmentFileCntForCd2": "1",
    "attachmentFileKey": "210_N_1_230111N210_%E8%AA%8D%E8%A8%BC_53_*****_*****",
    "attachmentFileName": "210-203156_01_002.pdf\\n210-203156_01_003.pdf\\n210-203156_02_004.pdf",
    "bodySar": "―",
    "date": "2022-12-23",
    "elecWave": "200MF1D 24050~24250MHz 6.4mW",
    "fqMaintainFunc": "無",
    "name": "DTEN Inc",
    "note": "",
    "number": "210-203156",
    "organName": "MiCOM Labs",
    "radioEquipmentCode": "第2条第8号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "DTEN D7X 75= [DB71475, DB71475-S1]"
}

Radio record 2

Certification date
2022-12-23
Applicant
DTEN Inc
Model / equipment
DTEN D7X 75= [DB71475, DB71475-S1]
Certifying organization
MiCOM Labs
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19
Emission, frequency and power
83M5F1D 2402~2480MHz 0.05mW/MHz 83M5G1D 2402~2480MHz 0.05mW/MHz 83M5G1D 2402~2480MHz 0.05mW/MHz 26M0F1D 2402~2480MHz 5.00mW 83M5F1D 2402~2480MHz 0.10mW/MHz 83M5G1D 2402~2480MHz 0.10mW/MHz 83M5G1D 2402~2480MHz 0.10mW/MHz 26M0F1D 2402~2480MHz 4.00mW 26M0F1D 2402~2480MHz 4.00mW 26M0G1D 2412~2472MHz 7.0mW/MHz 26M0D1D 2412~2472MHz 9.0mW/MHz 26M0D1D 2412~2472MHz 8.0mW/MHz 40M0D1D 2422~2462MHz 3.0mW/MHz 20M0D1D 2412~2472MHz 8.0mW/MHz 40M0D1D 2422~2462MHz 4.0mW/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "0",
    "attachmentFileCntForCd2": "5",
    "attachmentFileKey": "210_N_1_230111N210_%E8%AA%8D%E8%A8%BC_54_*****_*****",
    "attachmentFileName": "210-203156_02_001.pdf\\n210-203156_02_002.pdf\\n210-203156_02_003.pdf\\n210-203156_02_004.pdf\\n210-203156_02_005.pdf",
    "bodySar": "―",
    "date": "2022-12-23",
    "elecWave": "83M5F1D 2402~2480MHz 0.05mW/MHz\\n83M5G1D 2402~2480MHz 0.05mW/MHz\\n83M5G1D 2402~2480MHz 0.05mW/MHz\\n26M0F1D 2402~2480MHz 5.00mW\\n83M5F1D 2402~2480MHz 0.10mW/MHz\\n83M5G1D 2402~2480MHz 0.10mW/MHz\\n83M5G1D 2402~2480MHz 0.10mW/MHz\\n26M0F1D 2402~2480MHz 4.00mW\\n26M0F1D 2402~2480MHz 4.00mW\\n26M0G1D 2412~2472MHz 7.0mW/MHz\\n26M0D1D 2412~2472MHz 9.0mW/MHz\\n26M0D1D 2412~2472MHz 8.0mW/MHz\\n40M0D1D 2422~2462MHz 3.0mW/MHz\\n20M0D1D 2412~2472MHz 8.0mW/MHz\\n40M0D1D 2422~2462MHz 4.0mW/MHz",
    "fqMaintainFunc": "無",
    "name": "DTEN Inc",
    "note": "",
    "number": "210-203156",
    "organName": "MiCOM Labs",
    "radioEquipmentCode": "第2条第19号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "DTEN D7X 75= [DB71475, DB71475-S1]"
}

Radio record 3

Certification date
2022-12-23
Applicant
DTEN Inc
Model / equipment
DTEN D7X 75= [DB71475, DB71475-S1]
Certifying organization
MiCOM Labs
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
20M0D1D 5180~5240MHz 5.0mW/MHz 20M0D1D 5180~5240MHz 5.0mW/MHz 40M0D1D 5190~5230MHz 2.0mW/MHz 20M0D1D 5180~5240MHz 4.0mW/MHz 40M0D1D 5190~5230MHz 2.0mW/MHz 80M0D1D 5210~5210MHz 1.0mW/MHz 160MD1D 5250~5570MHz 1.0mW/MHz 20M0D1D 5260~5320MHz 3.0mW/MHz 20M0D1D 5260~5320MHz 3.0mW/MHz 40M0D1D 5270~5310MHz 2.0mW/MHz 20M0D1D 5260~5320MHz 3.0mW/MHz 40M0D1D 5270~5310MHz 2.0mW/MHz 80M0D1D 5290~5290MHz 1.0mW/MHz 20M0D1D 5500~5720MHz 8.0mW/MHz 20M0D1D 5500~5720MHz 9.0mW/MHz 40M0D1D 5510~5710MHz 5.0mW/MHz 20M0D1D 5500~5720MHz 8.0mW/MHz 40M0D1D 5510~5710MHz 4.0mW/MHz 80M0D1D 5530~5690MHz 3.0mW/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "0",
    "attachmentFileCntForCd2": "2",
    "attachmentFileKey": "210_N_1_230111N210_%E8%AA%8D%E8%A8%BC_55_*****_*****",
    "attachmentFileName": "210-203156_02_001.pdf\\n210-203156_02_002.pdf",
    "bodySar": "―",
    "date": "2022-12-23",
    "elecWave": "20M0D1D 5180~5240MHz 5.0mW/MHz\\n20M0D1D 5180~5240MHz 5.0mW/MHz\\n40M0D1D 5190~5230MHz 2.0mW/MHz\\n20M0D1D 5180~5240MHz 4.0mW/MHz\\n40M0D1D 5190~5230MHz 2.0mW/MHz\\n80M0D1D 5210~5210MHz 1.0mW/MHz\\n160MD1D 5250~5570MHz 1.0mW/MHz\\n20M0D1D 5260~5320MHz 3.0mW/MHz\\n20M0D1D 5260~5320MHz 3.0mW/MHz\\n40M0D1D 5270~5310MHz 2.0mW/MHz\\n20M0D1D 5260~5320MHz 3.0mW/MHz\\n40M0D1D 5270~5310MHz 2.0mW/MHz\\n80M0D1D 5290~5290MHz 1.0mW/MHz\\n20M0D1D 5500~5720MHz 8.0mW/MHz\\n20M0D1D 5500~5720MHz 9.0mW/MHz\\n40M0D1D 5510~5710MHz 5.0mW/MHz\\n20M0D1D 5500~5720MHz 8.0mW/MHz\\n40M0D1D 5510~5710MHz 4.0mW/MHz\\n80M0D1D 5530~5690MHz 3.0mW/MHz",
    "fqMaintainFunc": "無",
    "name": "DTEN Inc",
    "note": "",
    "number": "210-203156",
    "organName": "MiCOM Labs",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "DTEN D7X 75= [DB71475, DB71475-S1]"
}

Radio record 4

Certification date
2022-12-23
Applicant
DTEN Inc
Model / equipment
DTEN D7X 75= [DB71475, DB71475-S1]
Certifying organization
MiCOM Labs
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 80
Emission, frequency and power
20M0D1D 5955~6415MHz 4.0mW/MHz 40M0D1D 5965~6405MHz 3.0mW/MHz 80M0D1D 5985~6385MHz 1.5mW/MHz 160MD1D 6025~6345MHz 1.5mW/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "0",
    "attachmentFileCntForCd2": "1",
    "attachmentFileKey": "210_N_1_230111N210_%E8%AA%8D%E8%A8%BC_56_*****_*****",
    "attachmentFileName": "210-203156_02_001.pdf",
    "bodySar": "―",
    "date": "2022-12-23",
    "elecWave": "20M0D1D 5955~6415MHz 4.0mW/MHz\\n40M0D1D 5965~6405MHz 3.0mW/MHz\\n80M0D1D 5985~6385MHz 1.5mW/MHz\\n160MD1D 6025~6345MHz 1.5mW/MHz",
    "fqMaintainFunc": "無",
    "name": "DTEN Inc",
    "note": "",
    "number": "210-203156",
    "organName": "MiCOM Labs",
    "radioEquipmentCode": "第2条第80号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "DTEN D7X 75= [DB71475, DB71475-S1]"
}

Photos and test report documents

Source: Japan Ministry of Internal Affairs and Communications (MIC). Giteki search · Search FCCID.io