Giteki 211-150601

CP-VL5A

MIC source updated 2026-10-20. English translations shown first; original Japanese fields are available on each certificate.

Certificate information

Certificate number
211-150601
Applicant
Covia, Inc.
Model / equipment
CP-VL5A
Certification date
2015-07-30
Certifying organization
Bay Area Compliance Laboratories Corp
Certification year
2015

Radio equipment and technical records

Radio record 1

Certification date
2015-07-30
Applicant
Covia, Inc.
Model / equipment
CP-VL5A
Certifying organization
Bay Area Compliance Laboratories Corp
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 11, Subitem 3
Emission, frequency and power
G1A,G1B, G1C, G1D, G1E, G1F, G1X, G7W 832.4-837.6 MHz (200 kHz, 27 CH) 200 mW, 1922.6-1977.4 MHz (200 kHz, 275 CH) 200 mW
Body SAR
Supported
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "対応",
    "date": "2015-07-30",
    "elecWave": "G1A,G1B, G1C, G1D, G1E, G1F, G1X, G7W\\n832.4-837.6 MHz (200 kHz, 27 CH) 200 mW,\\n1922.6-1977.4 MHz (200 kHz, 275 CH) 200 mW",
    "fqMaintainFunc": "無",
    "name": "Covia, Inc.",
    "note": "",
    "number": "211-150601",
    "organName": "Bay Area Compliance Laboratories Corp",
    "radioEquipmentCode": "第2条第11号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "CP-VL5A"
}

Radio record 2

Certification date
2015-07-30
Applicant
Covia, Inc.
Model / equipment
CP-VL5A
Certifying organization
Bay Area Compliance Laboratories Corp
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 11, Subitem 7
Emission, frequency and power
G1A,G1B, G1C, G1D, G1E, G1F, G1X, G7W 832.4-837.6 MHz (200 kHz, 27 CH) 200 mW, 1922.6-1977.4 MHz (200 kHz, 275 CH) 200 mW
Body SAR
Supported
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "対応",
    "date": "2015-07-30",
    "elecWave": "G1A,G1B, G1C, G1D, G1E, G1F, G1X, G7W\\n832.4-837.6 MHz (200 kHz, 27 CH) 200 mW,\\n1922.6-1977.4 MHz (200 kHz, 275 CH) 200 mW",
    "fqMaintainFunc": "無",
    "name": "Covia, Inc.",
    "note": "",
    "number": "211-150601",
    "organName": "Bay Area Compliance Laboratories Corp",
    "radioEquipmentCode": "第2条第11号の7に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "CP-VL5A"
}

Radio record 3

Certification date
2015-07-30
Applicant
Covia, Inc.
Model / equipment
CP-VL5A
Certifying organization
Bay Area Compliance Laboratories Corp
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 11, Subitem 19
Emission, frequency and power
5M00: D1A, D1B, D1C, D1D, D1E, D1F, D1X, D7W, G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W 832.5-842.5 MHz (100 kHz, 101 CH),1450.4-1460.4 MHz (100 kHz, 101 CH), 1747.4-1782.4 MHz (100 kHz, 351 CH), 1922.5-1927.1 MHz (100 kHz, 47 CH), 1927.2-1977.5 MHz (100 kHz, 504 CH) 200 mW; 10M0: D1A, D1B, D1C, D1D, D1E, D1F, D1X, D7W, G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W 835-840 MHz (100 kHz, 51 CH),1452.9-1457.9 MHz (100 kHz, 51 CH), 1749.9-1779.9 MHz (100 kHz, 301 CH), 1925-1934.6 MHz (100 kHz, 97 CH), 1934.7-1975 MHz (100 kHz, 404 CH) 200 mW; 15M0: D1A, D1B, D1C, D1D, D1E, D1F, D1X, D7W, G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W 1455.4 MHz,1752.4-1777.4 MHz (100 kHz, 251 CH),1927.5-1942.1 MHz (100 kHz, 147 CH), 1942.2-1972.5 MHz (100 kHz, 304 CH) 200 mW; 20M0: D1A, D1B, D1C, D1D, D1E, D1F, D1X, D7W, G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W 1754.9-1774.9 MHz (100 kHz, 201 CH),1930-1949.6 MHz (100 kHz, 197 CH),1949.7-1970 MHz (100 kHz, 204 CH) 200 mW
Body SAR
Supported
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "対応",
    "date": "2015-07-30",
    "elecWave": "5M00: D1A, D1B, D1C, D1D, D1E, D1F, D1X, D7W, G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W  832.5-842.5 MHz (100 kHz, 101 CH),1450.4-1460.4 MHz (100 kHz, 101 CH), 1747.4-1782.4 MHz (100 kHz, 351 CH), 1922.5-1927.1 MHz (100 kHz, 47 CH), 1927.2-1977.5 MHz (100 kHz, 504 CH) 200 mW;\\n10M0: D1A, D1B, D1C, D1D, D1E, D1F, D1X, D7W, G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W  835-840 MHz (100 kHz, 51 CH),1452.9-1457.9 MHz (100 kHz, 51 CH), 1749.9-1779.9 MHz (100 kHz, 301 CH), 1925-1934.6 MHz (100 kHz, 97 CH), 1934.7-1975 MHz (100 kHz, 404 CH) 200 mW;\\n15M0: D1A, D1B, D1C, D1D, D1E, D1F, D1X, D7W, G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W  1455.4 MHz,1752.4-1777.4 MHz (100 kHz, 251 CH),1927.5-1942.1 MHz (100 kHz, 147 CH), 1942.2-1972.5 MHz (100 kHz, 304 CH) 200 mW;\\n20M0: D1A, D1B, D1C, D1D, D1E, D1F, D1X, D7W, G1A, G1B, G1C, G1D, G1E, G1F, G1X, G7W  1754.9-1774.9 MHz (100 kHz, 201 CH),1930-1949.6 MHz (100 kHz, 197 CH),1949.7-1970 MHz (100 kHz, 204 CH) 200 mW     ",
    "fqMaintainFunc": "無",
    "name": "Covia, Inc.",
    "note": "",
    "number": "211-150601",
    "organName": "Bay Area Compliance Laboratories Corp",
    "radioEquipmentCode": "第2条第11号の19に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "CP-VL5A"
}

Radio record 4

Certification date
2015-07-30
Applicant
Covia, Inc.
Model / equipment
CP-VL5A
Certifying organization
Bay Area Compliance Laboratories Corp
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19
Emission, frequency and power
F1D, G1D 2402-2480 MHz (1 MHz, 79 CH) 0.05 mW\/MHz; G1D 2402-2480 MHz (2 MHz, 40 CH) 0.3 mW; G1D 2412-2472 MHz (5 MHz, 13 CH) 4 mW\/MHz; G1D, D1D 2412-2472 MHz (5 MHz, 13 CH) 1 mW\/MHz; G1D, D1D 2422-2462 MHz (5 MHz, 9 CH) 1 mW\/MHz;
Body SAR
Supported
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "",
    "attachmentFileCntForCd2": "",
    "attachmentFileKey": "",
    "attachmentFileName": "",
    "bodySar": "対応",
    "date": "2015-07-30",
    "elecWave": "F1D, G1D 2402-2480 MHz (1 MHz, 79 CH) 0.05 mW\\/MHz;\\nG1D 2402-2480 MHz (2 MHz, 40 CH) 0.3 mW;\\nG1D 2412-2472 MHz (5 MHz, 13 CH) 4 mW\\/MHz;\\nG1D, D1D 2412-2472 MHz (5 MHz, 13 CH) 1 mW\\/MHz;\\nG1D, D1D 2422-2462 MHz (5 MHz, 9 CH) 1 mW\\/MHz;",
    "fqMaintainFunc": "無",
    "name": "Covia, Inc.",
    "note": "",
    "number": "211-150601",
    "organName": "Bay Area Compliance Laboratories Corp",
    "radioEquipmentCode": "第2条第19号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "CP-VL5A"
}

Photos and test report documents

No attachment documents are listed in this MIC record.

Source: Japan Ministry of Internal Affairs and Communications (MIC). Giteki search · Search FCCID.io