Giteki 214-250603

SOUTH; Model: ME, ALPS 1, ALPS 2, Insight V4, ME Plus, DotLas Plus, RobotSLAM II, RobotSLAM Lite II

MIC source updated 2026-10-19. English translations shown first; original Japanese fields are available on each certificate.

Certificate information

Certificate number
214-250603
Applicant
South Surveying & Mapping Technology Co., Ltd.
Model / equipment
SOUTH; Model: ME, ALPS 1, ALPS 2, Insight V4, ME Plus, DotLas Plus, RobotSLAM II, RobotSLAM Lite II
Certification date
2025-10-29
Certifying organization
Eurofins Electrical & Electronic Testing
Certification year
2025

Radio equipment and technical records

Radio record 1

Certification date
2025-10-29
Applicant
South Surveying & Mapping Technology Co., Ltd.
Model / equipment
SOUTH; Model: ME, ALPS 1, ALPS 2, Insight V4, ME Plus, DotLas Plus, RobotSLAM II, RobotSLAM Lite II
Certifying organization
Eurofins Electrical & Electronic Testing
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19
Emission, frequency and power
78M4F1D 2402~2480MHz1MHz Spacing, 79CH BR 0.05mW/MHz 78M6G1D 2402~2480MHz1MHz Spacing, 79CH EDR 0.05mW/MHz 78M6G1D 2402~2480MHz1MHz Spacing, 79CH EDR 0.05mW/MHz 1M33F1D 2402~2480MHz2MHz Spacing, 40CH BLE 1M 2mW 13M9G1D 2412~2472MHz5MHz Spacing, 13CH b 3.5mW/MHz 16M8D1D 2412~2472MHz5MHz Spacing, 13CH g 2.5mW/MHz 17M8D1D 2412~2472MHz5MHz Spacing, 13CH n20 4.0mW/MHz 36M2D1D 2422~2462MHz5MHz Spacing, 9CH n40 4.0mW/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "3",
    "attachmentFileCntForCd2": "8",
    "attachmentFileKey": "214_N_1_251107N214_%E8%AA%8D%E8%A8%BC_50_*****_*****",
    "attachmentFileName": "214-250603_01_001.pdf\\n214-250603_01_002.pdf\\n214-250603_01_011.pdf\\n214-250603_02_004.pdf\\n214-250603_02_005.pdf\\n214-250603_02_006.pdf\\n214-250603_02_007.pdf\\n214-250603_02_008.pdf\\n214-250603_02_009.pdf\\n214-250603_02_010.pdf\\n214-250603_02_012.pdf",
    "bodySar": "―",
    "date": "2025-10-29",
    "elecWave": "78M4F1D 2402~2480MHz1MHz Spacing, 79CH BR 0.05mW/MHz\\n78M6G1D 2402~2480MHz1MHz Spacing, 79CH EDR 0.05mW/MHz\\n78M6G1D 2402~2480MHz1MHz Spacing, 79CH EDR 0.05mW/MHz\\n1M33F1D 2402~2480MHz2MHz Spacing, 40CH BLE 1M 2mW\\n13M9G1D 2412~2472MHz5MHz Spacing, 13CH b 3.5mW/MHz\\n16M8D1D 2412~2472MHz5MHz Spacing, 13CH g 2.5mW/MHz\\n17M8D1D 2412~2472MHz5MHz Spacing, 13CH n20 4.0mW/MHz\\n36M2D1D 2422~2462MHz5MHz Spacing, 9CH n40 4.0mW/MHz",
    "fqMaintainFunc": "無",
    "name": "South Surveying & Mapping Technology Co., Ltd.",
    "note": "",
    "number": "214-250603",
    "organName": "Eurofins Electrical & Electronic Testing",
    "radioEquipmentCode": "第2条第19号に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "SOUTH; Model: ME, ALPS 1, ALPS 2, Insight V4, ME Plus, DotLas Plus, RobotSLAM II, RobotSLAM Lite II"
}

Radio record 2

Certification date
2025-10-29
Applicant
South Surveying & Mapping Technology Co., Ltd.
Model / equipment
SOUTH; Model: ME, ALPS 1, ALPS 2, Insight V4, ME Plus, DotLas Plus, RobotSLAM II, RobotSLAM Lite II
Certifying organization
Eurofins Electrical & Electronic Testing
Certification type
Construction design certification under mutual recognition (MRA)
Radio equipment class
Specific radio equipment specified in Article 2, Item 19, Subitem 3
Emission, frequency and power
16M8D1D 5180~5240MHz20MHz Spacing, 4CH a 1.5mW/MHz 17M9D1D 5180~5240MHz20MHz Spacing, 4CH n20 3.0mW/MHz 17M8D1D 5180~5240MHz20MHz Spacing, 4CH ac20 3.0mW/MHz 35M0D1D 5190~5230MHz40MHz Spacing, 2CH n40 1.5mW/MHz 35M0D1D 5190~5230MHz40MHz Spacing, 2CH ac40 1.5mW/MHz 75M0D1D 5210~5210MHz1CH ac80 1.0mW/MHz
Body SAR
―
Frequency maintenance function
No
Spurious emission rules
New spurious emission rules
All original source fields
{
    "attachmentFileCntForCd1": "0",
    "attachmentFileCntForCd2": "2",
    "attachmentFileKey": "214_N_1_251107N214_%E8%AA%8D%E8%A8%BC_51_*****_*****",
    "attachmentFileName": "214-250603_02_001.pdf\\n214-250603_02_002.pdf",
    "bodySar": "―",
    "date": "2025-10-29",
    "elecWave": "16M8D1D 5180~5240MHz20MHz Spacing, 4CH a 1.5mW/MHz\\n17M9D1D 5180~5240MHz20MHz Spacing, 4CH n20 3.0mW/MHz\\n17M8D1D 5180~5240MHz20MHz Spacing, 4CH ac20 3.0mW/MHz\\n35M0D1D 5190~5230MHz40MHz Spacing, 2CH n40 1.5mW/MHz\\n35M0D1D 5190~5230MHz40MHz Spacing, 2CH ac40 1.5mW/MHz\\n75M0D1D 5210~5210MHz1CH ac80 1.0mW/MHz",
    "fqMaintainFunc": "無",
    "name": "South Surveying & Mapping Technology Co., Ltd.",
    "note": "",
    "number": "214-250603",
    "organName": "Eurofins Electrical & Electronic Testing",
    "radioEquipmentCode": "第2条第19号の3に規定する特定無線設備",
    "spuriousRules": "新スプリアス規定",
    "techCode": "相互承認(MRA)による工事設計認証",
    "typeName": "SOUTH; Model: ME, ALPS 1, ALPS 2, Insight V4, ME Plus, DotLas Plus, RobotSLAM II, RobotSLAM Lite II"
}

Photos and test report documents

Source: Japan Ministry of Internal Affairs and Communications (MIC). Giteki search · Search FCCID.io