FCC ID O6E714050B
UHF Fixed Station Transceiver
by Midland Radio Corporation
Grantee Code: O6E Product Code: 714050B
Latest application date: 2000-12-05
FCC ID Device Details
| FCC ID | O6E714050B |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | O6E |
| Product Code | 714050B |
| Applicant Business | Midland Radio Corporation 🇺🇸 |
| Related Domains | |
| Equipment Class | UHF Fixed Station Transceiver |
| Test Firm | Hyak Laboratories, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 440-475 MHz | Original Equipment | 2000-12-05 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| users manual | Users Manual | 2000-12-05 | PDF 964.5 KB |
| internal photos | Internal Photos | 2000-12-05 | PDF 1.9 MB |
| external photos | External Photos | 2000-12-05 | PDF 1 MB |
| sample and location | ID Label/Location Info | 2000-12-05 | PDF 137.5 KB |
| 14 Dec PA Schematic | Schematics | 2000-12-05 | PDF 31.3 KB |
| Schematic Diagram | Schematics | 2000-12-05 | PDF 45.5 KB |
| VCO Schematic | Schematics | 2000-12-05 | PDF 30 KB |
| operational description | Operational Description | 2000-12-05 | PDF 20.5 KB |
| test report | Test Report | 2000-12-05 | PDF 2.3 MB |
| statement requested 01 09 01 | Cover Letter(s) | 2000-12-05 | PDF 19 KB |
| alignment procedure | Parts List/Tune Up Info | 2000-12-05 | PDF 22.5 KB |
Application Information
| Application ID | EuYlHP6aMzJvm8wxRf+ZSg== |
|---|---|
| Final Action Date | 2000-12-05 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0005867551 |
| Model | 714050B |
| Frequency Range | 440-475 MHz |
| Equipment Class | TNB - Licensed Non-Broadcast Station Transmitter |
| Device Description | UHF Fixed Station Transceiver |
| Responsible Party | Jeff Brame, Director of Engineering, jbrame@midlandradio.com |
| Test Firm | Rowland Johnson, Hyak Laboratories, Inc., 703-451-1188 |
| TCB Email | eric@timcoengr.com |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 6 meters from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 1000 W and the peak radiated output power must not exceed 1000 W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| EuYlHP6aMzJvm8wxRf+ZSg== | 2000-12-05 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application EuYlHP6aMzJvm8wxRf+ZSg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 12/05/2000 Application Dated: 12/05/2000 |
| Midland Radio Corporation |
| 5900 Paretta Drive |
| Kansas City, MO 64120-2134 |
| Attention: Jeff Brame , Director of Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | O6E714050B |
| Name of Grantee: | Midland Radio Corporation |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | UHF Fixed Station Transceiver |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BJ | 90 | 440.0 - 475.0 | 70.0 | 0.00015 % | 16K0F3E |
| BJ | 90 | 440.0 - 475.0 | 70.0 | 0.00015 % | 11K0F3E |
| The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 6 meters from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 1000 W and the peak radiated output power must not exceed 1000 W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. |
| BJ: | The output power is continuously variable from the value listed in this entry to 35%-40% of the value listed. |
EAS Grant - Application EuYlHP6aMzJvm8wxRf+ZSg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Midland Radio Corporation 5900 Paretta Drive Kansas City, MO 64120-2134 United States |
Date of Grant: 12/05/2000 Application Dated: 12/05/2000 |
| Attention: Jeff Brame , Director of Engineering |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | O6E714050B |
| Name of Grantee: | Midland Radio Corporation |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | UHF Fixed Station Transceiver |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BJ | 90 | 440.0 - 475.0 | 70.0 | 0.00015 % | 16K0F3E |
| BJ | 90 | 440.0 - 475.0 | 70.0 | 0.00015 % | 11K0F3E |
| The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a separation distance of at least 6 meters from all persons during normal operation. The peak conducted output power at each antenna terminal must not exceed 1000 W and the peak radiated output power must not exceed 1000 W EIRP. Users and installers must be provided with appropriate antenna installation instructions and transmitter operating conditions, including antenna co-location requirements of §1.1307(b)(3), for satisfying RF exposure compliance. |
| BJ: | The output power is continuously variable from the value listed in this entry to 35%-40% of the value listed. |
| Mail To: |