FCC ID QMHA100

DECT 6.0 Cordless Phone (Base)

by Xingtel Xiamen Group Co., Ltd.

Grantee Code: QMH   Product Code: A100
Latest application date: 2010-10-24

FCC ID Device Details

FCC IDQMHA100
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeQMH
Product CodeA100
Applicant BusinessXingtel Xiamen Group Co., Ltd. 🇨🇳
Related Domains xingtel.com
Equipment ClassDECT 6.0 Cordless Phone (Base)
Test FirmBay Area Compliance Laboratory Corp. (Shenzhen)

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1921.536-1928.448 MHzOriginal Equipment2010-10-24
1921.536-1928.448 MHzOriginal Equipment2010-10-24

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2010-10-24PDF 1.1 MB
Internal PhotosInternal Photos2010-10-24PDF 358.4 KB
Internal PhotosInternal Photos2010-10-24PDF 536.1 KB
External PhotosExternal Photos2010-10-24PDF 217.2 KB
External PhotosExternal Photos2010-10-24PDF 325.6 KB
FCC ID LabelID Label/Location Info2010-10-24PDF 216.2 KB
FCC ID LabelID Label/Location Info2010-10-24PDF 212.9 KB
Test Setup PhotosTest Setup Photos2010-10-24PDF 350.6 KB
Test Setup PhotosTest Setup Photos2010-10-24PDF 586.4 KB
SAR Test ReportRF Exposure Info2010-10-24PDF 3.1 MB
Test ReportTest Report2010-10-24PDF 803.1 KB
Test ReportTest Report2010-10-24PDF 936.8 KB
UTAM LetterAttestation Statements2010-10-24PDF 19.8 KB
Confidential Request LetterCover Letter(s)2010-10-24PDF 75.1 KB
Products SIimiliarityCover Letter(s)2010-10-24PDF 150 KB
RF Exposure InformationRF Exposure Info2010-10-24PDF 19.5 KB

Application Information

Application IDeSSNUq/4iMwjtWIc3SlwPg==
Final Action Date2010-10-24
Application PurposeOriginal Equipment
Applicant FRN0021283460
ModelA100
Frequency Range1921.536-1928.448 MHz
Equipment ClassPUB - Part 15 Unlicensed PCS Base Station
Device DescriptionDECT 6.0 Cordless Phone (Base)
Responsible PartySimon Liu, Director, simon@xingtel.com , 86-592-5625929
Test FirmJohn Chan, Bay Area Compliance Laboratory Corp. (Shenzhen), john.chan@baclcorp.com , 08675533320018
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeA3: Unlicensed Personal Communication System (PCS) devices
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
eSSNUq/4iMwjtWIc3SlwPg==2010-10-24Original Equipment
2bkgNBxGFNQZdYURU6qKCw==2010-10-24Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
1921.536-1928.448 MHz0.107000015D
1921.536-1928.448 MHz0.064100015D68

Grants

TCB Grant - Application eSSNUq/4iMwjtWIc3SlwPg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 10/24/2010

Application Dated: 10/24/2010
Xingtel Xiamen Group Co., Ltd.
Xingtel Building, Chuangxin Road,
Torch Hi-tech Industrial District
Xiamen, 361006
China
 
Attention: Simon Liu , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QMHA100
Name of Grantee:  Xingtel Xiamen Group Co., Ltd.
Equipment Class: Part 15 Unlicensed PCS Base Station
Notes: DECT 6.0 Cordless Phone (Base)
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
68 15D 1921.536  -  1928.448 0.0641  

Power listed is conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

68: This grant does not pertain to equipment approval requirements under Part 68.

EAS Grant - Application eSSNUq/4iMwjtWIc3SlwPg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Xingtel Xiamen Group Co., Ltd.
Xingtel Building, Chuangxin Road, Torch Hi-tech Industrial District
Xiamen, 361006
China
  Date of Grant: 10/24/2010

Application Dated: 10/24/2010
 
Attention: Simon Liu , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QMHA100
Name of Grantee:  Xingtel Xiamen Group Co., Ltd.
Equipment Class: Part 15 Unlicensed PCS Base Station
Notes: DECT 6.0 Cordless Phone (Base)
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
68 15D 1921.536  -  1928.448 0.0641  

Power listed is conducted. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.


68: This grant does not pertain to equipment approval requirements under Part 68.

TCB Grant - Application 2bkgNBxGFNQZdYURU6qKCw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratory Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 10/24/2010

Application Dated: 10/24/2010
Xingtel Xiamen Group Co., Ltd.
Xingtel Building, Chuangxin Road,
Torch Hi-tech Industrial District
Xiamen, 361006
China
 
Attention: Simon Liu , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QMHA100
Name of Grantee:  Xingtel Xiamen Group Co., Ltd.
Equipment Class: Part 15 Unlicensed PCS portable Tx held to ear
Notes: DECT 6.0 Cordless Phone (Handset)
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15D 1921.536  -  1928.448 0.107  

Output is conducted. Device must not be co-located or operating in conjunction with any other antenna or transmitter. Device has been tested for SAR compliance for head and body configurations as described in this filing. End-users must be informed of the operating requirements for satisfying RF exposure compliance. The highest reported SAR value is: Head 0.03 W/kg

EAS Grant - Application 2bkgNBxGFNQZdYURU6qKCw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Xingtel Xiamen Group Co., Ltd.
Xingtel Building, Chuangxin Road, Torch Hi-tech Industrial District
Xiamen, 361006
China
  Date of Grant: 10/24/2010

Application Dated: 10/24/2010
 
Attention: Simon Liu , Director

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  QMHA100
Name of Grantee:  Xingtel Xiamen Group Co., Ltd.
Equipment Class: Part 15 Unlicensed PCS portable Tx held to ear
Notes: DECT 6.0 Cordless Phone (Handset)
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15D 1921.536  -  1928.448 0.107  

Output is conducted. Device must not be co-located or operating in conjunction with any other antenna or transmitter. Device has been tested for SAR compliance for head and body configurations as described in this filing. End-users must be informed of the operating requirements for satisfying RF exposure compliance. The highest reported SAR value is: Head 0.03 W/kg



Mail To: