FCC ID 2A5MW-XS14PRO

Mini smartphone

by Shenzhen SOYES Premium Technology limited

Grantee Code: 2A5MW   Product Code: XS14PRO
Latest application date: 2023-07-09

FCC ID Device Details

FCC ID2A5MW-XS14PRO
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A5MW
Product CodeXS14PRO
Applicant BusinessShenzhen SOYES Premium Technology limited 🇨🇳
Equipment ClassMini smartphone
Test FirmShenzhen Anbotek Compliance Laboratory Limited

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5745-5825 MHzOriginal Equipment2023-07-09
2580-2610 MHzOriginal Equipment2023-07-09
2412-2462 MHzOriginal Equipment2023-07-09

Exhibits

DocumentTypeAvailableFile
U ManualUsers Manual2023-07-09PDF 1.2 MB
User ManualUsers Manual2023-07-09PDF 1.2 MB
User manualUsers Manual2023-07-09PDF 1.2 MB
Internal PhotosInternal Photos2023-07-09PDF 5 MB
External PhotoExternal Photos2023-07-09PDF 2.6 MB
External PhotosExternal Photos2023-07-09PDF 2.6 MB
External photosExternal Photos2023-07-09PDF 2.6 MB
Label and LocationID Label/Location Info2023-07-09PDF 1.1 MB
Label and locationID Label/Location Info2023-07-09PDF 1.1 MB
label&label locationID Label/Location Info2023-07-09PDF 1.1 MB
T Setup photoTest Setup Photos2023-07-09PDF 1.5 MB
Test Setup PhotosTest Setup Photos2023-07-09PDF 1.7 MB
Test photosTest Setup Photos2023-07-09PDF 1.7 MB
ANT REPORTTest Report2023-07-09PDF 385.4 KB
BLE Appendix Test DataTest Report2023-07-09PDF 3.9 MB
FCC-GSM Appendix Test Data_1-36Test Report2023-07-09PDF 3.9 MB
FCC-GSM Appendix Test Data_37-71Test Report2023-07-09PDF 3.8 MB
FCC-LTE Appendix Test Data B5Test Report2023-07-09PDF 5.5 MB
FCC-LTE Appendix Test Data B7Test Report2023-07-09PDF 5.5 MB
FCC-LTE Appendix Test Data_B38_1-40Test Report2023-07-09PDF 4.1 MB
FCC-LTE Appendix Test Data_B38_41-80Test Report2023-07-09PDF 4.3 MB
FCC-LTE Appendix Test Data_B41_1-40Test Report2023-07-09PDF 4.1 MB
FCC-LTE Appendix Test Data_B41_41-78Test Report2023-07-09PDF 4.3 MB
FCC-WCDMA Appendix Test Data_B5Test Report2023-07-09PDF 3.8 MB
FCC-WLAN Appendix Test DataTest Report2023-07-09PDF 3.5 MB
RLAN Appendix Test DataTest Report2023-07-09PDF 2.8 MB
Report FCC 15.247_Wi-Fi 2.4GTest Report2023-07-09PDF 1.3 MB
Report FCC Part 22,24,27,90_LTE Band5,7,38,41Test Report2023-07-09PDF 968.6 KB
ReportFCC15.247 BLETest Report2023-07-09PDF 2.2 MB
ReportFCC15.407 Wi-Fi5.8G aTest Report2023-07-09PDF 1.4 MB
Test Report SARRF Exposure Info2023-07-09PDF 4.8 MB
XS14Pro _Report FCC Part 22_WCDMA Band5Test Report2023-07-09PDF 732.4 KB
XS14Pro_Report FCC Part 22,24_GSM,GPRS, EGPRS 850 1900Test Report2023-07-09PDF 761.3 KB
antenna reportTest Report2023-07-09PDF 385.4 KB
2.911 (d)(5)(i)CertificationEquipmentTypev1.2Attestation Statements2023-07-09PDF 93.8 KB
2.911 (d)(5)(ii)CertificiationApplicantv1.2Attestation Statements2023-07-09PDF 88.7 KB
2.911_(d)(5)(i) Certification Equipment Type v1.2Attestation Statements2023-07-09PDF 93.8 KB
2.911_(d)(5)(ii) Certificiation Applicant v1.2Attestation Statements2023-07-09PDF 88.7 KB
2.911_(d)(7) US Agent for Service of Process v1.3Attestation Statements2023-07-09PDF 97.8 KB
2.911_(d)(7)USAgentforServiceofProcessv1.2Attestation Statements2023-07-09PDF 97.8 KB
Agent Authorization Rev 1.0Cover Letter(s)2023-07-09PDF 63.9 KB
AgentAuthorizationRev1.0Cover Letter(s)2023-07-09PDF 63.9 KB
Declaration Letter of Model DifferenceCover Letter(s)2023-07-09PDF 67.7 KB
Declarationon Model DifferencesCover Letter(s)2023-07-09PDF 67.7 KB
FCC Long Term Only Confidentiality Request Rev4.1Cover Letter(s)2023-07-09PDF 63.5 KB
FCC Short_Long Term Confidentiality Request Rev4.1Cover Letter(s)2023-07-09PDF 63.5 KB
FCC Software Configuration Control Declaration Rev1.0Cover Letter(s)2023-07-09PDF 93.2 KB
Long Term ConfidentialityCover Letter(s)2023-07-09PDF 63.5 KB
Block Metadata onlyBlock DiagramPDF 52.6 KB
BlockDiagram Metadata onlyBlock DiagramPDF 52.6 KB
SCH Metadata onlySchematicsPDF 898.2 KB
OP Metadata onlyOperational DescriptionPDF 78.9 KB
software security requirement Metadata onlySDR Software/Security InfPDF 141.4 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 118.2 KB
Tune-Up Metadata onlyParts List/Tune Up InfoPDF 63.8 KB

Application Information

Application IDtxbjHdxt9ehtMvjzEsp2Cw==
Final Action Date2023-07-09
Application PurposeOriginal Equipment
Applicant FRN0032077026
ModelXS14PRO
Frequency Range5745-5825 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionMini smartphone
Responsible Partyxueping zhang, Sales Manager, 1178374914@qq.com , 0755-83647157
Technical ContactShenzhen SOYES Premium Technology limited, 1178374914@qq.com
Test FirmJeff Zhu, Shenzhen Anbotek Compliance Laboratory Limited, jeff.zhu@anbotek.com , 13798230942
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn, hotspot and simultaneous SAR accessory are 0.21 W/kg, 0.15 W/kg, 0.15 W/kg and 1.19 W/kg respectively.

Applications

Application IDDatePurpose
txbjHdxt9ehtMvjzEsp2Cw==2023-07-09Original Equipment
hhNUoXzQQjvVO2cv4tcKMw==2023-07-09Original Equipment
d/mbHvt76fpIheQin+ERpg==2023-07-09Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824.2-848.8 MHz0.59292.5ppm246KF9W22H
824.7-848.3 MHz0.39172.5ppm2M69G7D22H
826.4-846.6 MHz0.09772.5ppm4M20F9W22H
829-844 MHz0.12332.5ppm9M01W7D22H
829-844 MHz0.29852.5ppm9M03G7D22H
1850.2-1909.8 MHz0.56892.5ppm245KGXW24E
1850.2-1909.8 MHz0.23392.5ppm244KG7W24E
1850.2-1909.8 MHz0.52972.5ppm251KF9W24E
2402-2480 MHz0.00515C
2412-2462 MHz0.206115C
2503.5-2682.5 MHz0.34122.5ppm13M5G7D27
2503.5-2682.5 MHz0.10352.5ppm13M5W7D27
2506-2680 MHz0.33192.5ppm18M0G7D27
2506-2680 MHz0.10122.5ppm17M9W7D27
2507.5-2562.5 MHz0.35732.5ppm13M5G7D27
2507.5-2562.5 MHz0.10352.5ppm13M5W7D27
2510-2560 MHz0.33342.5ppm18M0G7D27
2510-2560 MHz0.09622.5ppm17M9W7D27
2577.5-2612.5 MHz0.2362.5ppm13M5G7D27
2577.5-2612.5 MHz0.10642.5ppm13M5W7D27
2580-2610 MHz0.23172.5ppm18M0G7D27
2580-2610 MHz0.10472.5ppm18M0W7D27
5745-5825 MHz0.021700015E

Grants

TCB Grant - Application txbjHdxt9ehtMvjzEsp2Cw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/09/2023

Application Dated: 07/09/2023
Shenzhen SOYES Premium Technology limited
502 West Gate, Building 427, Bagua Ling Industrial
Zone, No.47 Bagua Fourth Road, Futian District
Shenzhen, 518000
China
 
Attention: xueping zhang , Sales Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A5MW-XS14PRO
Name of Grantee:  Shenzhen SOYES Premium Technology limited
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Mini smartphone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15E 5745.0  -  5825.0 0.0217  

Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn, hotspot and simultaneous SAR accessory are 0.21 W/kg, 0.15 W/kg, 0.15 W/kg and 1.19 W/kg respectively.

EAS Grant - Application txbjHdxt9ehtMvjzEsp2Cw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen SOYES Premium Technology limited
502 West Gate, Building 427, Bagua Ling Industrial Zone, No.47 Bagua Fourth Road, Futian District
Shenzhen, 518000
China
  Date of Grant: 07/09/2023

Application Dated: 07/09/2023
 
Attention: xueping zhang , Sales Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A5MW-XS14PRO
Name of Grantee:  Shenzhen SOYES Premium Technology limited
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Mini smartphone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15E 5745.0  -  5825.0 0.0217  

Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn, hotspot and simultaneous SAR accessory are 0.21 W/kg, 0.15 W/kg, 0.15 W/kg and 1.19 W/kg respectively.



TCB Grant - Application hhNUoXzQQjvVO2cv4tcKMw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/09/2023

Application Dated: 07/09/2023
Shenzhen SOYES Premium Technology limited
502 West Gate, Building 427, Bagua Ling Industrial
Zone, No.47 Bagua Fourth Road, Futian District
Shenzhen, 518000
China
 
Attention: xueping zhang , Sales Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A5MW-XS14PRO
Name of Grantee:  Shenzhen SOYES Premium Technology limited
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Mini smartphone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.4223 2.5  PM 245KGXW
22H 824.2  -  848.8 0.542 2.5  PM 244KG7W
22H 824.2  -  848.8 0.5929 2.5  PM 246KF9W
24E 1850.2  -  1909.8 0.5689 2.5  PM 245KGXW
24E 1850.2  -  1909.8 0.2339 2.5  PM 244KG7W
24E 1850.2  -  1909.8 0.5297 2.5  PM 251KF9W
22H 826.4  -  846.6 0.0977 2.5  PM 4M20F9W
22H 824.7  -  848.3 0.3917 2.5  PM 2M69G7D
22H 829.0  -  844.0 0.2985 2.5  PM 9M03G7D
22H 829.0  -  844.0 0.1233 2.5  PM 9M01W7D
27 2507.5  -  2562.5 0.3573 2.5  PM 13M5G7D
27 2507.5  -  2562.5 0.1035 2.5  PM 13M5W7D
27 2510.0  -  2560.0 0.3334 2.5  PM 18M0G7D
27 2510.0  -  2560.0 0.0962 2.5  PM 17M9W7D
27 2577.5  -  2612.5 0.236 2.5  PM 13M5G7D
27 2577.5  -  2612.5 0.1064 2.5  PM 13M5W7D
27 2580.0  -  2610.0 0.2317 2.5  PM 18M0G7D
27 2580.0  -  2610.0 0.1047 2.5  PM 18M0W7D
27 2503.5  -  2682.5 0.3412 2.5  PM 13M5G7D
27 2503.5  -  2682.5 0.1035 2.5  PM 13M5W7D
27 2506.0  -  2680.0 0.3319 2.5  PM 18M0G7D
27 2506.0  -  2680.0 0.1012 2.5  PM 17M9W7D

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn, hotspot and simultaneous SAR accessory are 0.71 W/kg, 0.48 W/kg, 0.48 W/kg and 1.19 W/kg respectively.

EAS Grant - Application hhNUoXzQQjvVO2cv4tcKMw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen SOYES Premium Technology limited
502 West Gate, Building 427, Bagua Ling Industrial Zone, No.47 Bagua Fourth Road, Futian District
Shenzhen, 518000
China
  Date of Grant: 07/09/2023

Application Dated: 07/09/2023
 
Attention: xueping zhang , Sales Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A5MW-XS14PRO
Name of Grantee:  Shenzhen SOYES Premium Technology limited
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Mini smartphone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.4223 2.5  PM 245KGXW
22H 824.2  -  848.8 0.542 2.5  PM 244KG7W
22H 824.2  -  848.8 0.5929 2.5  PM 246KF9W
24E 1850.2  -  1909.8 0.5689 2.5  PM 245KGXW
24E 1850.2  -  1909.8 0.2339 2.5  PM 244KG7W
24E 1850.2  -  1909.8 0.5297 2.5  PM 251KF9W
22H 826.4  -  846.6 0.0977 2.5  PM 4M20F9W
22H 824.7  -  848.3 0.3917 2.5  PM 2M69G7D
22H 829.0  -  844.0 0.2985 2.5  PM 9M03G7D
22H 829.0  -  844.0 0.1233 2.5  PM 9M01W7D
27 2507.5  -  2562.5 0.3573 2.5  PM 13M5G7D
27 2507.5  -  2562.5 0.1035 2.5  PM 13M5W7D
27 2510.0  -  2560.0 0.3334 2.5  PM 18M0G7D
27 2510.0  -  2560.0 0.0962 2.5  PM 17M9W7D
27 2577.5  -  2612.5 0.236 2.5  PM 13M5G7D
27 2577.5  -  2612.5 0.1064 2.5  PM 13M5W7D
27 2580.0  -  2610.0 0.2317 2.5  PM 18M0G7D
27 2580.0  -  2610.0 0.1047 2.5  PM 18M0W7D
27 2503.5  -  2682.5 0.3412 2.5  PM 13M5G7D
27 2503.5  -  2682.5 0.1035 2.5  PM 13M5W7D
27 2506.0  -  2680.0 0.3319 2.5  PM 18M0G7D
27 2506.0  -  2680.0 0.1012 2.5  PM 17M9W7D

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn, hotspot and simultaneous SAR accessory are 0.71 W/kg, 0.48 W/kg, 0.48 W/kg and 1.19 W/kg respectively.



TCB Grant - Application d/mbHvt76fpIheQin+ERpg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/09/2023

Application Dated: 07/09/2023
Shenzhen SOYES Premium Technology limited
502 West Gate, Building 427, Bagua Ling Industrial
Zone, No.47 Bagua Fourth Road, Futian District
Shenzhen, 518000
China
 
Attention: xueping zhang , Sales Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A5MW-XS14PRO
Name of Grantee:  Shenzhen SOYES Premium Technology limited
Equipment Class: Digital Transmission System
Notes: Mini smartphone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.005  
15C 2412.0  -  2462.0 0.2061  

Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn, hotspot and simultaneous SAR accessory are 0.49 W/kg, 0.36 W/kg, 0.36 W/kg and 1.19 W/kg respectively.

EAS Grant - Application d/mbHvt76fpIheQin+ERpg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen SOYES Premium Technology limited
502 West Gate, Building 427, Bagua Ling Industrial Zone, No.47 Bagua Fourth Road, Futian District
Shenzhen, 518000
China
  Date of Grant: 07/09/2023

Application Dated: 07/09/2023
 
Attention: xueping zhang , Sales Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A5MW-XS14PRO
Name of Grantee:  Shenzhen SOYES Premium Technology limited
Equipment Class: Digital Transmission System
Notes: Mini smartphone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.005  
15C 2412.0  -  2462.0 0.2061  

Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn, hotspot and simultaneous SAR accessory are 0.49 W/kg, 0.36 W/kg, 0.36 W/kg and 1.19 W/kg respectively.