FCC ID 2A9UPS5G

Solis 5G

by SIMO Holdings Inc.

Grantee Code: 2A9UP   Product Code: S5G
Latest application date: 2023-03-29

FCC ID Device Details

FCC ID2A9UPS5G
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2A9UP
Product CodeS5G
Applicant BusinessSIMO Holdings Inc. 🇰🇾
Related Domains simo.co morlab.cn
Equipment ClassSolis 5G
Test FirmShenzhen Morlab Communications Technology Co. Ltd.

Additional Linked Details

ManufacturerSIMO Holdings Inc.
Certification Date2023-03-29
Manufacturer Website www.simo.co
5G Certified

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
3550-3600 MHzChange in identification of presently authorized equipment. Original FCC ID: HLZM3 Grant Date: 03/14/20232023-03-29
2412-2462 MHzChange in identification of presently authorized equipment. Original FCC ID: HLZM3 Grant Date: 03/14/20232023-03-29
5745-5825 MHzChange in identification of presently authorized equipment. Original FCC ID: HLZM3 Grant Date: 03/14/20232023-03-29
665.5-695.5 MHzChange in identification of presently authorized equipment. Original FCC ID: HLZM3 Grant Date: 03/14/20232023-03-29

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2023-09-19PDF 2.8 MB
Internal PhotosInternal Photos2023-09-19PDF 3.1 MB
External PhotosExternal Photos2023-09-19PDF 395 KB
ID Label/Location InfoID Label/Location Info2023-03-29PDF 91.3 KB
FCC Attestation Letter COVERED EQUIPMENTAttestation Statements2023-03-29PDF 70.4 KB
FCC US Agent LetterAttestation Statements2023-03-29PDF 1.7 MB
FCC Authorization LetterCover Letter(s)2023-03-29PDF 213.4 KB
FCC Change in ID Authorization LetterCover Letter(s)2023-03-29PDF 54.8 KB
confidentialityCover Letter(s)2023-03-29PDF 279.5 KB

Application Information

Application IDxbF1Ig+v5abCbSN/FeXXmw==
Final Action Date2023-03-29
Application PurposeChange in identification of presently authorized equipment. Original FCC ID: HLZM3 Grant Date: 03/14/2023
Applicant FRN0033218850
ModelS5G
Frequency Range3550-3600 MHz
Equipment ClassCBE - Citizens Band End User Devices
Device DescriptionSolis 5G
Responsible PartyGinn Yin, noc_admin@simo.co , +8675586196493
AgentWendy Wendy Wendy, Shenzhen Morlab Communications Technology Co., Ltd, wp.zhan@morlab.cn
Technical ContactWendy Zhan, Shenzhen Morlab Communications Technology Co., Ltd, wp.zhan@morlab.cn , +8675536698541
Non-Technical ContactWendy Zhan, Shenzhen Morlab Communications Technology Co., Ltd, wp.zhan@morlab.cn , +8675536698541
Test FirmMr. Su Feng, Shenzhen Morlab Communications Technology Co. Ltd., Zx.sun@morlab.cn , +86 755 36698566
TCB Emailcertification@telefication.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityYes
Short-Term Confidentiality Date09/19/2023
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power is EIRP. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 10 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.40 W/kg and 1.03 W/kg, respectively.

Applications

Application IDDatePurpose
xbF1Ig+v5abCbSN/FeXXmw==2023-03-29Change in identification of presently authorized equipment. Original FCC ID: HLZM3 Grant Date: 03/14/2023
gv6d0zTefZD4A7JnoXBskA==2023-03-29Change in identification of presently authorized equipment. Original FCC ID: HLZM3 Grant Date: 03/14/2023
S4OK/KkbmA7wjJA61ONQLw==2023-03-29Change in identification of presently authorized equipment. Original FCC ID: HLZM3 Grant Date: 03/14/2023
BJRB7bK63p3zK+Zdosb/Fw==2023-03-29Change in identification of presently authorized equipment. Original FCC ID: HLZM3 Grant Date: 03/14/2023
3IbrmYeseRtHkYU9crjKwg==2023-03-29Change in identification of presently authorized equipment. Original FCC ID: HLZM3 Grant Date: 03/14/2023

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
15BCC
665.5-695.5 MHz0.140.082ppm18M0G7D27
665.5-695.5 MHz0.1140.082ppm17M9W7D27
665.5-695.5 MHz0.1160.082ppm4M50W7D27
665.5-695.5 MHz0.2830.051ppm17M9G7D27
665.5-695.5 MHz0.2860.051ppm17M9G7D27
665.5-695.5 MHz0.2150.051ppm17M9W7D27
699.7-715.3 MHz0.1670.081ppm9M00G7D27
699.7-715.3 MHz0.1360.081ppm8M98W7D27
699.7-715.3 MHz0.1370.081ppm4M50W7D27
706.5-713.5 MHz0.1660.08ppm8M99G7D27
706.5-713.5 MHz0.1350.08ppm8M98W7D27
706.5-713.5 MHz0.1360.08ppm4M50W7D27
779.5-784.5 MHz0.1420.06ppm8M97G7D27
779.5-784.5 MHz0.1130.06ppm8M97W7D27
779.5-784.5 MHz0.1150.06ppm4M50W7D27
824.7-848.3 MHz0.2670.067ppm9M02G7D22H
824.7-848.3 MHz0.210.067ppm8M99W7D22H
824.7-848.3 MHz0.2160.067ppm2M70W7D22H
824.7-848.3 MHz0.2990.068ppm13M5G7D22H
824.7-848.3 MHz0.2670.068ppm13M5W7D22H
824.7-848.3 MHz0.30.068ppm9M01G7D22H
826.5-846.5 MHz0.5460.061ppm18M1G7D22H
826.5-846.5 MHz0.5580.061ppm18M0G7D22H
826.5-846.5 MHz0.4520.061ppm17M9W7D22H
1710.7-1754.3 MHz0.2880.034ppm18M0G7D27
1710.7-1754.3 MHz0.2430.034ppm18M0W7D27
1710.7-1779.3 MHz0.2920.03ppm17M9G7D27
1710.7-1779.3 MHz0.2360.03ppm17M9W7D27
1710.7-1779.3 MHz0.240.03ppm4M50W7D27
1712.5-1777.5 MHz0.3350.03ppm38M6G7D27
1712.5-1777.5 MHz0.3380.03ppm38M5G7D27
1712.5-1777.5 MHz0.2390.03ppm38M6W7D27
1850.7-1914.3 MHz0.4520.03ppm17M9G7D24E
1850.7-1914.3 MHz0.3630.03ppm18M0W7D24E
1850.7-1909.3 MHz0.360.028ppm8M98W7D24E
1852.5-1907.5 MHz0.5110.02ppm17M9G7D24E
1852.5-1907.5 MHz0.520.02ppm17M9G7D24E
1852.5-1907.5 MHz0.4060.02ppm17M9W7D24E
2307.5-2312.5 MHz0.4270.024ppm9M00G7D27
2307.5-2312.5 MHz0.3520.024ppm8M99W7D27
2412-2462 MHz0.750000015CCC, MO
2498.5-2687.5 MHz0.7570.022ppm18M0G7D27
2498.5-2687.5 MHz0.6070.022ppm18M0W7D27
2498.5-2687.5 MHz0.6180.022ppm13M5W7D27
2501.01-2685 MHz0.9480.01ppm96M3G7D27
2501.01-2685 MHz1.0090.01ppm96M0G7D27
2501.01-2685 MHz0.6080.01ppm96M2W7D27
2502.5-2567.5 MHz0.2370.021ppm18M0G7D27
2502.5-2567.5 MHz0.1950.021ppm18M0W7D27
2505-2565 MHz0.3380.015ppm17M9G7D27
2505-2565 MHz0.3520.015ppm17M9G7D27
2505-2565 MHz0.240.015ppm18M0W7D27
2572.5-2617.5 MHz0.3390.022ppm18M0G7D27
2572.5-2617.5 MHz0.2770.022ppm18M0W7D27
2572.5-2617.5 MHz0.2780.022ppm4M50W7D27
2575-2615 MHz0.3240.02ppm35M7G7D27
2575-2615 MHz0.3380.02ppm35M8G7D27
2575-2615 MHz0.1750.02ppm35M8W7D27
3452.5-3547.5 MHz0.1850.013ppm18M0G7D27
3452.5-3547.5 MHz0.1490.013ppm18M0W7D27
3452.5-3547.5 MHz0.1510.013ppm13M5W7D27
3455.01-3544.995 MHz0.6750.014ppm96M1G7D27
3455.01-3544.995 MHz0.6780.014ppm96M1G7D27
3455.01-3544.995 MHz0.4550.014ppm96M1W7D27
3455.01-3544.995 MHz0.5570.014ppm96M1G7D27
3455.01-3544.995 MHz0.5660.014ppm96M1G7D27
3455.01-3544.995 MHz0.3840.014ppm96M1W7D27
3550-3600 MHz0.1840.014ppm18M0G7D96
3550-3600 MHz0.1480.014ppm18M0W7D96
3550-3700 MHz0.1930.014ppm18M0G7D96
3550-3700 MHz0.1540.014ppm18M0W7D96
3550-3700 MHz0.1610.014ppm4M51W7D96
3705-3975 MHz0.7380.014ppm96M3G7D27
3705-3975 MHz0.7530.014ppm96M0G7D27
3705-3975 MHz0.4520.014ppm96M5W7D27
3705-3795 MHz0.5680.014ppm96M3G7D27
3705-3795 MHz0.5930.014ppm96M0G7D27
3705-3795 MHz0.3230.014ppm96M5W7D27
5180-5240 MHz0.08715ECC, MO
5745-5825 MHz0.1515ECC, MO

Grants

TCB Grant - Application xbF1Ig+v5abCbSN/FeXXmw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 03/29/2023

Application Dated: 03/22/2023
SIMO Holdings Inc.
P.O. Box P.O.Box 309,
Ugland House, GrandCayman, KY1-1104,
Cayman Islands
 
Attention: Ginn Yin

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A9UPS5G
Name of Grantee:  SIMO Holdings Inc.
Equipment Class: Citizens Band End User Devices
Notes: Solis 5G
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
96 3550.0  -  3600.0 0.184 0.014  PM 18M0G7D
96 3550.0  -  3600.0 0.148 0.014  PM 18M0W7D
96 3550.0  -  3700.0 0.193 0.014  PM 18M0G7D
96 3550.0  -  3700.0 0.154 0.014  PM 18M0W7D
96 3550.0  -  3700.0 0.161 0.014  PM 4M51W7D

Output power is EIRP. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 10 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.40 W/kg and 1.03 W/kg, respectively.

EAS Grant - Application xbF1Ig+v5abCbSN/FeXXmw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SIMO Holdings Inc.
P.O.Box 309,
Ugland House, GrandCayman, KY1-1104,
Cayman Islands
  Date of Grant: 03/29/2023

Application Dated: 03/22/2023
 
Attention: Ginn Yin

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A9UPS5G
Name of Grantee:  SIMO Holdings Inc.
Equipment Class: Citizens Band End User Devices
Notes: Solis 5G
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
96 3550.0  -  3600.0 0.184 0.014  PM 18M0G7D
96 3550.0  -  3600.0 0.148 0.014  PM 18M0W7D
96 3550.0  -  3700.0 0.193 0.014  PM 18M0G7D
96 3550.0  -  3700.0 0.154 0.014  PM 18M0W7D
96 3550.0  -  3700.0 0.161 0.014  PM 4M51W7D

Output power is EIRP. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 10 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.40 W/kg and 1.03 W/kg, respectively.



TCB Grant - Application S4OK/KkbmA7wjJA61ONQLw==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 03/29/2023

Application Dated: 03/22/2023
SIMO Holdings Inc.
P.O. Box P.O.Box 309,
Ugland House, GrandCayman, KY1-1104,
Cayman Islands
 
Attention: Ginn Yin

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A9UPS5G
Name of Grantee:  SIMO Holdings Inc.
Equipment Class: Digital Transmission System
Notes: Solis 5G
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.75  

Power Output is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 10 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.42 W/kg and 1.45 W/kg, respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application S4OK/KkbmA7wjJA61ONQLw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SIMO Holdings Inc.
P.O.Box 309,
Ugland House, GrandCayman, KY1-1104,
Cayman Islands
  Date of Grant: 03/29/2023

Application Dated: 03/22/2023
 
Attention: Ginn Yin

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A9UPS5G
Name of Grantee:  SIMO Holdings Inc.
Equipment Class: Digital Transmission System
Notes: Solis 5G
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.75  

Power Output is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 10 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.42 W/kg and 1.45 W/kg, respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application gv6d0zTefZD4A7JnoXBskA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 03/29/2023

Application Dated: 03/22/2023
SIMO Holdings Inc.
P.O. Box P.O.Box 309,
Ugland House, GrandCayman, KY1-1104,
Cayman Islands
 
Attention: Ginn Yin

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A9UPS5G
Name of Grantee:  SIMO Holdings Inc.
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: Solis 5G
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application gv6d0zTefZD4A7JnoXBskA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SIMO Holdings Inc.
P.O.Box 309,
Ugland House, GrandCayman, KY1-1104,
Cayman Islands
  Date of Grant: 03/29/2023

Application Dated: 03/22/2023
 
Attention: Ginn Yin

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A9UPS5G
Name of Grantee:  SIMO Holdings Inc.
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: Solis 5G
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application BJRB7bK63p3zK+Zdosb/Fw==

Mail To:
FCC Home | Search | Updates | E-Filing | Initiatives | For Consumers | Find People
Office of Engineering and Technology
  FCC > FCC E-filing > OET Application Error Page FCC Site Map
Invalid Page Access:

You have incorrectly accessed this page. Please return to the previous page using your browser's "back" button or navigate back to the homepage.

Please report this error to FCC OET Systems Support

 



Federal Communications Commission
45 L Street NE
Washington, DC 20554
More FCC Contact Information...
Phone:  888-CALL-FCC (225-5322)
TTY:  888-TELL-FCC (835-5322)
Fax:  202-418-0232
E-mail:  fccinfo@fcc.gov
- Web Policies & Privacy Statement
- Customer Service Standards
- Freedom of Information Act

EAS Grant - Application BJRB7bK63p3zK+Zdosb/Fw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SIMO Holdings Inc.
P.O.Box 309,
Ugland House, GrandCayman, KY1-1104,
Cayman Islands
  Date of Grant: 03/29/2023

Application Dated: 03/22/2023
 
Attention: Ginn Yin

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A9UPS5G
Name of Grantee:  SIMO Holdings Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Solis 5G
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.087  
CC MO 15E 5745.0  -  5825.0 0.15  

Power Output is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 10 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.60 W/kg and 1.28 W/kg, respectively.


CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application 3IbrmYeseRtHkYU9crjKwg==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 03/29/2023

Application Dated: 03/22/2023
SIMO Holdings Inc.
P.O. Box P.O.Box 309,
Ugland House, GrandCayman, KY1-1104,
Cayman Islands
 
Attention: Ginn Yin

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A9UPS5G
Name of Grantee:  SIMO Holdings Inc.
Equipment Class: PCS Licensed Transmitter
Notes: Solis 5G
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 790.5  -  795.5 0.126 0.072  PM 9M00G7D
90 790.5  -  795.5 0.1 0.072  PM 8M98W7D
90 814.7  -  823.3 0.255 0.068  PM 9M01G7D
90 814.7  -  823.3 0.204 0.068  PM 8M98W7D
90 814.7  -  823.3 0.3 0.068  PM 4M50G7D
90 814.7  -  823.3 0.267 0.068  PM 4M51W7D
24E 1850.7  -  1909.3 0.444 0.028  PM 18M0G7D
24E 1850.7  -  1909.3 0.349 0.028  PM 18M0W7D
24E 1850.7  -  1909.3 0.36 0.028  PM 8M98W7D
27 1710.7  -  1754.3 0.288 0.034  PM 18M0G7D
27 1710.7  -  1754.3 0.243 0.034  PM 18M0W7D
22H 824.7  -  848.3 0.267 0.067  PM 9M02G7D
22H 824.7  -  848.3 0.21 0.067  PM 8M99W7D
22H 824.7  -  848.3 0.216 0.067  PM 2M70W7D
27 2502.5  -  2567.5 0.237 0.021  PM 18M0G7D
27 2502.5  -  2567.5 0.195 0.021  PM 18M0W7D
27 699.7  -  715.3 0.167 0.081  PM 9M00G7D
27 699.7  -  715.3 0.136 0.081  PM 8M98W7D
27 699.7  -  715.3 0.137 0.081  PM 4M50W7D
27 779.5  -  784.5 0.142 0.06  PM 8M97G7D
27 779.5  -  784.5 0.113 0.06  PM 8M97W7D
27 779.5  -  784.5 0.115 0.06  PM 4M50W7D
27 706.5  -  713.5 0.166 0.08  PM 8M99G7D
27 706.5  -  713.5 0.135 0.08  PM 8M98W7D
27 706.5  -  713.5 0.136 0.08  PM 4M50W7D
24E 1850.7  -  1914.3 0.452 0.03  PM 17M9G7D
24E 1850.7  -  1914.3 0.363 0.03  PM 18M0W7D
22H 824.7  -  848.3 0.299 0.068  PM 13M5G7D
22H 824.7  -  848.3 0.267 0.068  PM 13M5W7D
22H 824.7  -  848.3 0.3 0.068  PM 9M01G7D
27 2307.5  -  2312.5 0.427 0.024  PM 9M00G7D
27 2307.5  -  2312.5 0.352 0.024  PM 8M99W7D
27 2572.5  -  2617.5 0.339 0.022  PM 18M0G7D
27 2572.5  -  2617.5 0.277 0.022  PM 18M0W7D
27 2572.5  -  2617.5 0.278 0.022  PM 4M50W7D
27 2498.5  -  2687.5 0.757 0.022  PM 18M0G7D
27 2498.5  -  2687.5 0.607 0.022  PM 18M0W7D
27 2498.5  -  2687.5 0.618 0.022  PM 13M5W7D
27 3452.5  -  3547.5 0.185 0.013  PM 18M0G7D
27 3452.5  -  3547.5 0.149 0.013  PM 18M0W7D
27 3452.5  -  3547.5 0.151 0.013  PM 13M5W7D
27 1710.7  -  1779.3 0.292 0.03  PM 17M9G7D
27 1710.7  -  1779.3 0.236 0.03  PM 17M9W7D
27 1710.7  -  1779.3 0.24 0.03  PM 4M50W7D
27 665.5  -  695.5 0.14 0.082  PM 18M0G7D
27 665.5  -  695.5 0.114 0.082  PM 17M9W7D
27 665.5  -  695.5 0.116 0.082  PM 4M50W7D
24E 1852.5  -  1907.5 0.511 0.02  PM 17M9G7D
24E 1852.5  -  1907.5 0.52 0.02  PM 17M9G7D
24E 1852.5  -  1907.5 0.406 0.02  PM 17M9W7D
22H 826.5  -  846.5 0.546 0.061  PM 18M1G7D
22H 826.5  -  846.5 0.558 0.061  PM 18M0G7D
22H 826.5  -  846.5 0.452 0.061  PM 17M9W7D
27 2505.0  -  2565.0 0.338 0.015  PM 17M9G7D
27 2505.0  -  2565.0 0.352 0.015  PM 17M9G7D
27 2505.0  -  2565.0 0.24 0.015  PM 18M0W7D
27 2575.0  -  2615.0 0.324 0.02  PM 35M7G7D
27 2575.0  -  2615.0 0.338 0.02  PM 35M8G7D
27 2575.0  -  2615.0 0.175 0.02  PM 35M8W7D
27 2501.01  -  2685.0 0.948 0.01  PM 96M3G7D
27 2501.01  -  2685.0 1.009 0.01  PM 96M0G7D
27 2501.01  -  2685.0 0.608 0.01  PM 96M2W7D
27 1712.5  -  1777.5 0.335 0.03  PM 38M6G7D
27 1712.5  -  1777.5 0.338 0.03  PM 38M5G7D
27 1712.5  -  1777.5 0.239 0.03  PM 38M6W7D
27 665.5  -  695.5 0.283 0.051  PM 17M9G7D
27 665.5  -  695.5 0.286 0.051  PM 17M9G7D
27 665.5  -  695.5 0.215 0.051  PM 17M9W7D
27 3705.0  -  3975.0 0.738 0.014  PM 96M3G7D
27 3705.0  -  3975.0 0.753 0.014  PM 96M0G7D
27 3705.0  -  3975.0 0.452 0.014  PM 96M5W7D
27 3455.01  -  3544.995 0.675 0.014  PM 96M1G7D
27 3455.01  -  3544.995 0.678 0.014  PM 96M1G7D
27 3455.01  -  3544.995 0.455 0.014  PM 96M1W7D
27 3705.0  -  3795.0 0.568 0.014  PM 96M3G7D
27 3705.0  -  3795.0 0.593 0.014  PM 96M0G7D
27 3705.0  -  3795.0 0.323 0.014  PM 96M5W7D
27 3455.01  -  3544.995 0.557 0.014  PM 96M1G7D
27 3455.01  -  3544.995 0.566 0.014  PM 96M1G7D
27 3455.01  -  3544.995 0.384 0.014  PM 96M1W7D

Output power is ERP for Part 22, Part 27 and Part 90; EIRP for Part 24 and Part 27. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 10 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 1.12 W/kg and 1.59 W/kg, respectively.

EAS Grant - Application 3IbrmYeseRtHkYU9crjKwg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SIMO Holdings Inc.
P.O.Box 309,
Ugland House, GrandCayman, KY1-1104,
Cayman Islands
  Date of Grant: 03/29/2023

Application Dated: 03/22/2023
 
Attention: Ginn Yin

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2A9UPS5G
Name of Grantee:  SIMO Holdings Inc.
Equipment Class: PCS Licensed Transmitter
Notes: Solis 5G
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
90 790.5  -  795.5 0.126 0.072  PM 9M00G7D
90 790.5  -  795.5 0.1 0.072  PM 8M98W7D
90 814.7  -  823.3 0.255 0.068  PM 9M01G7D
90 814.7  -  823.3 0.204 0.068  PM 8M98W7D
90 814.7  -  823.3 0.3 0.068  PM 4M50G7D
90 814.7  -  823.3 0.267 0.068  PM 4M51W7D
24E 1850.7  -  1909.3 0.444 0.028  PM 18M0G7D
24E 1850.7  -  1909.3 0.349 0.028  PM 18M0W7D
24E 1850.7  -  1909.3 0.36 0.028  PM 8M98W7D
27 1710.7  -  1754.3 0.288 0.034  PM 18M0G7D
27 1710.7  -  1754.3 0.243 0.034  PM 18M0W7D
22H 824.7  -  848.3 0.267 0.067  PM 9M02G7D
22H 824.7  -  848.3 0.21 0.067  PM 8M99W7D
22H 824.7  -  848.3 0.216 0.067  PM 2M70W7D
27 2502.5  -  2567.5 0.237 0.021  PM 18M0G7D
27 2502.5  -  2567.5 0.195 0.021  PM 18M0W7D
27 699.7  -  715.3 0.167 0.081  PM 9M00G7D
27 699.7  -  715.3 0.136 0.081  PM 8M98W7D
27 699.7  -  715.3 0.137 0.081  PM 4M50W7D
27 779.5  -  784.5 0.142 0.06  PM 8M97G7D
27 779.5  -  784.5 0.113 0.06  PM 8M97W7D
27 779.5  -  784.5 0.115 0.06  PM 4M50W7D
27 706.5  -  713.5 0.166 0.08  PM 8M99G7D
27 706.5  -  713.5 0.135 0.08  PM 8M98W7D
27 706.5  -  713.5 0.136 0.08  PM 4M50W7D
24E 1850.7  -  1914.3 0.452 0.03  PM 17M9G7D
24E 1850.7  -  1914.3 0.363 0.03  PM 18M0W7D
22H 824.7  -  848.3 0.299 0.068  PM 13M5G7D
22H 824.7  -  848.3 0.267 0.068  PM 13M5W7D
22H 824.7  -  848.3 0.3 0.068  PM 9M01G7D
27 2307.5  -  2312.5 0.427 0.024  PM 9M00G7D
27 2307.5  -  2312.5 0.352 0.024  PM 8M99W7D
27 2572.5  -  2617.5 0.339 0.022  PM 18M0G7D
27 2572.5  -  2617.5 0.277 0.022  PM 18M0W7D
27 2572.5  -  2617.5 0.278 0.022  PM 4M50W7D
27 2498.5  -  2687.5 0.757 0.022  PM 18M0G7D
27 2498.5  -  2687.5 0.607 0.022  PM 18M0W7D
27 2498.5  -  2687.5 0.618 0.022  PM 13M5W7D
27 3452.5  -  3547.5 0.185 0.013  PM 18M0G7D
27 3452.5  -  3547.5 0.149 0.013  PM 18M0W7D
27 3452.5  -  3547.5 0.151 0.013  PM 13M5W7D
27 1710.7  -  1779.3 0.292 0.03  PM 17M9G7D
27 1710.7  -  1779.3 0.236 0.03  PM 17M9W7D
27 1710.7  -  1779.3 0.24 0.03  PM 4M50W7D
27 665.5  -  695.5 0.14 0.082  PM 18M0G7D
27 665.5  -  695.5 0.114 0.082  PM 17M9W7D
27 665.5  -  695.5 0.116 0.082  PM 4M50W7D
24E 1852.5  -  1907.5 0.511 0.02  PM 17M9G7D
24E 1852.5  -  1907.5 0.52 0.02  PM 17M9G7D
24E 1852.5  -  1907.5 0.406 0.02  PM 17M9W7D
22H 826.5  -  846.5 0.546 0.061  PM 18M1G7D
22H 826.5  -  846.5 0.558 0.061  PM 18M0G7D
22H 826.5  -  846.5 0.452 0.061  PM 17M9W7D
27 2505.0  -  2565.0 0.338 0.015  PM 17M9G7D
27 2505.0  -  2565.0 0.352 0.015  PM 17M9G7D
27 2505.0  -  2565.0 0.24 0.015  PM 18M0W7D
27 2575.0  -  2615.0 0.324 0.02  PM 35M7G7D
27 2575.0  -  2615.0 0.338 0.02  PM 35M8G7D
27 2575.0  -  2615.0 0.175 0.02  PM 35M8W7D
27 2501.01  -  2685.0 0.948 0.01  PM 96M3G7D
27 2501.01  -  2685.0 1.009 0.01  PM 96M0G7D
27 2501.01  -  2685.0 0.608 0.01  PM 96M2W7D
27 1712.5  -  1777.5 0.335 0.03  PM 38M6G7D
27 1712.5  -  1777.5 0.338 0.03  PM 38M5G7D
27 1712.5  -  1777.5 0.239 0.03  PM 38M6W7D
27 665.5  -  695.5 0.283 0.051  PM 17M9G7D
27 665.5  -  695.5 0.286 0.051  PM 17M9G7D
27 665.5  -  695.5 0.215 0.051  PM 17M9W7D
27 3705.0  -  3975.0 0.738 0.014  PM 96M3G7D
27 3705.0  -  3975.0 0.753 0.014  PM 96M0G7D
27 3705.0  -  3975.0 0.452 0.014  PM 96M5W7D
27 3455.01  -  3544.995 0.675 0.014  PM 96M1G7D
27 3455.01  -  3544.995 0.678 0.014  PM 96M1G7D
27 3455.01  -  3544.995 0.455 0.014  PM 96M1W7D
27 3705.0  -  3795.0 0.568 0.014  PM 96M3G7D
27 3705.0  -  3795.0 0.593 0.014  PM 96M0G7D
27 3705.0  -  3795.0 0.323 0.014  PM 96M5W7D
27 3455.01  -  3544.995 0.557 0.014  PM 96M1G7D
27 3455.01  -  3544.995 0.566 0.014  PM 96M1G7D
27 3455.01  -  3544.995 0.384 0.014  PM 96M1W7D

Output power is ERP for Part 22, Part 27 and Part 90; EIRP for Part 24 and Part 27. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 10 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 1.12 W/kg and 1.59 W/kg, respectively.



Mail To: