F306W Fast Wireless Charger RF Exposure Info RF EXPOSURE REPORT Spigen Korea Co., Ltd.

Spigen Korea Co., Ltd. Fast Wireless Charger

FCC ID Filing: 2AFKNF306W
Purchase on Amazon: Fast Wireless Charger

Trouble Viewing? See the or view the HTML Version or PDF in frame
Page 1 of F306W Fast Wireless Charger RF Exposure Info RF EXPOSURE REPORT Spigen Korea Co., Ltd.
Page 2 of F306W Fast Wireless Charger RF Exposure Info RF EXPOSURE REPORT Spigen Korea Co., Ltd.
Page 3 of F306W Fast Wireless Charger RF Exposure Info RF EXPOSURE REPORT Spigen Korea Co., Ltd.
Page 4 of F306W Fast Wireless Charger RF Exposure Info RF EXPOSURE REPORT Spigen Korea Co., Ltd.
Page 5 of F306W Fast Wireless Charger RF Exposure Info RF EXPOSURE REPORT Spigen Korea Co., Ltd.
Page 6 of F306W Fast Wireless Charger RF Exposure Info RF EXPOSURE REPORT Spigen Korea Co., Ltd.

Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711036F-1
FCC ID: 2AFKNF306W
RF EXPOSURE REPORT
The device described below is tested by Dongguan Nore Testing Center Co., Ltd. to determine the maximum emission
levels emanating from the device, the severe levels which the device can endure and E.U.T.’s performance criterion.
The test results, data evaluation, test procedures, and equipment of configurations shown in this report were made in
accordance with the procedures in ANSI C63.10(2013).
Applicant
: Spigen Korea Co., Ltd.
Address
Manufacturer/Factory
: Shenzhen Huagon Technology Co.,LTD
Address
E.U.T.
: Fast Wireless Charger
Brand Name
: N/A
Model No.
: F306W
FCC ID
: 2AFKNF306W
No. 1709 STX-V Tower, 128, Gasan digital 1-ro, Geumcheon-gu, Seoul,
08507, Republic of Korea, South Korea
6th floor number two , North fourth ring road phoenix first industrial zone ,
Fuyong town Bao'an District, Shenzhen (518000)
Measurement Standard : FCC PART 15 Subpart C
Date of Receiver
: November 24, 2017
Date of Test
: November 24, 2017 to December 26, 2017
Date of Report
: December 26, 2017
In the configuration tested, the EUT complied with the standards specified above.
This test report is for the customer shown above and their specific product only. This report applies to above tested
sample only and shall not be reproduced in part without written approval of Dongguan Nore Testing Center Co., Ltd.
TEL: +86-769-22022444
FAX: +86-769-22022799
Web: www.ntc-c.com
Address: Building D, Gaosheng Science & Technology Park, Zhouxi Longxi Road, Nancheng District,
Dongguan City, Guangdong, China
Page 1 of 24
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711036F-1
FCC ID: 2AFKNF306W
1. GENERAL INFORMATION
1.1 Product Description for Equipment under Test
Product name
: Fast Wireless Charger
Main model
: F306W
Additional model
: N/A
Model difference
: N/A
Power Supply
: DC 5V 2A, DC 9V 1.67A, DC 12V 1.5A
Test voltage
: AC 120V 60Hz Adapter input
Adapter
: N/A
Cable
: N/A
Software version
: V1.0
Hardware version
: V1.0
Note
: N/A
Remark
: N/A
Frequency Range
: 105.5-204.5KHz
Page 2 of 6
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711036F-1
FCC ID: 2AFKNF306W
1.2 Related Submittal(s) / Grant (s)
This submittal(s) (test report) is intended for FCC ID: 2AFKNF306W filing to comply
with FCC Part 15 (2016), Subpart C Rule.
1.3 Test Facility and Location
Site Description
EMC
Lab
: Listed by CNAS, August 14, 2015
The certificate is valid until August 13, 2018
The Laboratory has been assessed and proved to
be in compliance with CNAS/CL01
The Certificate Registration Number is L5795.
Listed by A2LA, November 01, 2017
The certificate is valid until December 31, 2019
The Laboratory has been assessed and proved to
be in compliance with ISO17025
The Certificate Registration Number is 4429.01
Listed by FCC, November 06, 2017
The Designation Number is CN1214
Test Firm Registration Number: 907417
Name of Firm
Site Location
Listed by Industry Canada, June 08, 2017
The Certificate Registration Number. Is 46405-9743
: Dongguan Nore Testing Center Co., Ltd.
(Dongguan NTC Co., Ltd.)
: Building D, Gaosheng Science & Technology Park,
Zhouxi Longxi Road, Nancheng District, Dongguan
City, Guangdong Province, China
Page 3 of 6
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711036F-1
FCC ID: 2AFKNF306W
2. Method of measurement
2.1 Applicable standard
According to 1.1307(b)(1), system operating under the provisions of this section
shall be operated in amnner that ensures that the public is not exposed to radio
frequency energy level in excess of the commission's guidelines.
According to 1.1310 and 2.1093 RF exposure is calculated.
According to KDB680106 D01V02: RF exposure wireless charging apps v02.
2.2 Test Setup
2.3 Test procedure
1. The RF exposure test was performed on 360 degree turn table in anechoic
chamber;
2.The measurement probe was placed at test distance 10cm which is between the
edge of the charger and the geometric centre of probe.
3. The turn table was rotated 360d degree to search of highest strength.
4. The highest emission level was recorded and compared with limit as soon as
measurement of each points (A,B,C,D,E) were completed.
5. The EUT were measured according to the dictates of KDB 680106D01V02
Page 4 of 6
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711036F-1
FCC ID: 2AFKNF306W
2.4 Equipment approval considerations
1. The EUT dose comply with item 5.2 of KDB 680106D01V02
a, Power transfer frequency is less than 1MHz.
YES; the device operated in the frequency range from 105.5-204.5KHz.
b, Output power from each primary coil is less than 5 watts
YES; the maximum output power of the primary coil is 4W<5W.
c, The transfer system includes only single primary and secondary coils. This includes
charging systems that may have multiple primary coils and clients that able to
detect and allow coupling only between individual pair of coils.
YES; the transfer system includes only single primary and secondary coils.
d, Client device is inserted in or placed directly in contact with the transmitter.
YES; Client device is placed directly in contact with the transmitter.
e, The maximum coupling surface area of the transmit (charging) device.
YES; The EUT coupling surface area was 82.6cm2>60cm2.
f, Aggregate leakage fields at 10cm surrounding the device from all simultaneous
transmitting coils are demonstrated to be less than 30% of the MPE limit.
YES; The EUT field strength levels are 30% x MPE limts.
2.5 E and H field strength
E-Filed strength at 10cm from the edges surrounding the
EUT(V/m)
Frequency
range
Test
Test
Test
Test
Test
Test
MHz
position position position position position position
0.1055-0.2045
1.33
2.08
0.65
0.26
1.63
1.99
H-Filed strength at 10cm from the edges surrounding the
EUT(A/m)
Test
Test
Test
Test
Test
Test
position position position position position position
0.1055-0.2045
0.86
0.75
0.68
0.86
0.66
0.91
Frequency
range
MHz
Limits
(V/m)
614
Limits
(A/m)
1.68
Page 5 of 6
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711036F-1
FCC ID: 2AFKNF306W
2.6 Test Photo
2.7 Test equipment list
Description
Manufacturer
Model Number
Serial
Number
Calibration
Date
Calibration
Due Date
3m semi-anechoic
chamber
Zhongyu electron
9.2*6.2*63.4
N/A
July 03,2015
July 02, 2020
Exposure lever tester
Narda
ELT-400
N-0231
June 29,2017 June 28, 2018
Magnetic field probe
100cm2
Narda
ELT Probe
100cm2
M0675
June 29,2017 June 28, 2018
---End---
Page 6 of 6
Download: F306W Fast Wireless Charger RF Exposure Info RF EXPOSURE REPORT Spigen Korea Co., Ltd.
Mirror Download [FCC.gov]F306W Fast Wireless Charger RF Exposure Info RF EXPOSURE REPORT Spigen Korea Co., Ltd.
Document ID3704875
Application IDh1op8biJYo+bvnJ9T5QtuA==
Document Description18_F306W RFExp r2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeRF Exposure Info
Display FormatAdobe Acrobat PDF - pdf
Filesize22.86kB (285693 bits)
Date Submitted2018-01-08 00:00:00
Date Available2018-01-08 00:00:00
Creation Date2018-01-02 17:01:15
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2018-01-08 09:54:11
Document TitleRF EXPOSURE REPORT
Document CreatorPScript5.dll Version 5.2.2
Document Author: Rose

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Rose
Create Date                     : 2018:01:02 17:01:15+08:00
Modify Date                     : 2018:01:08 09:54:11+08:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2018:01:08 09:54:11+08:00
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Format                          : application/pdf
Title                           : Microsoft Word - RF EXPOSURE REPORT
Creator                         : Rose
Document ID                     : uuid:d21beecf-afcb-463d-b1fb-c5c45782d7c6
Instance ID                     : uuid:afa00ca8-c006-4c7c-ac96-b0fa3baa881c
Page Count                      : 6
EXIF Metadata provided by EXIF.tools

Facebook Twitter Google+ RSS © FCCID.io 2018