F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.

Spigen Korea Co., Ltd. Fast Wireless Charger

FCC ID Filing: 2AFKNF306W
Purchase on Amazon: Fast Wireless Charger

Trouble Viewing? See the or view the HTML Version or PDF in frame
Page 1 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 2 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 3 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 4 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 5 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 6 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 7 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 8 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 9 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 10 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 11 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 12 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 13 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 14 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 15 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 16 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 17 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 18 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 19 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 20 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 21 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 22 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 23 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 24 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 25 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 26 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 27 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 28 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 29 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 30 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 31 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 32 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 33 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 34 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 35 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 36 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 37 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 38 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 39 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Page 40 of F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.

Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Table of Contents
1. GENERAL INFORMATION ................................................................................................ 4
1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST .................................................................... 4
1.2 RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................ 5
1.3 TEST METHODOLOGY ...................................................................................................................... 5
1.4 EQUIPMENT MODIFICATIONS ............................................................................................................ 5
1.5 SUPPORT DEVICE ............................................................................................................................ 5
1.6 TEST FACILITY AND LOCATION.......................................................................................................... 6
1.7 SUMMARY OF TEST RESULTS ........................................................................................................... 6
2. SYSTEM TEST CONFIGURATION .................................................................................... 7
2.1 EUT CONFIGURATION ...................................................................................................................... 7
2.2 SPECIAL ACCESSORIES.................................................................................................................... 7
2.3 DESCRIPTION OF TEST MODES ......................................................................................................... 7
2.4 EUT EXERCISE ................................................................................................................................ 7
3. CONDUCTED EMISSIONS TEST ...................................................................................... 8
3.1 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION)..................................................................... 8
3.2 TEST CONDITION ............................................................................................................................. 8
3.3 MEASUREMENT RESULTS................................................................................................................. 8
4. RADIATED EMISSION TEST ........................................................................................... 15
4.1 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) ................................................................... 15
4.2 MEASUREMENT PROCEDURE ......................................................................................................... 16
4.3 LIMIT .............................................................................................................................................. 17
4.4 MEASUREMENT RESULTS
..................................................................................................... 18
5. 20DB BANDWIDTH .......................................................................................................... 37
5.1 MEASUREMENT PROCEDURE ......................................................................................................... 37
5.2 TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION)................................................................... 37
5.3 MEASUREMENT RESULTS............................................................................................................... 37
6. TEST EQUIPMENT LIST.................................................................................................. 40
Page 2 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Revision History of This Test Report
Report Number
Description
Issued Date
NTC1711180FV00
Initial Issue
2017-11-30
Page 3 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
1. GENERAL INFORMATION
1.1 Product Description for Equipment under Test
Product name
: Fast Wireless Charger
Main model
: F306W
Additional model
: N/A
Model difference
: N/A
Power Supply
: DC 5V 2A, DC 9V 1.67A, DC 12V 1.5A
Test voltage
: AC 120V 60Hz Adapter input
Adapter
: N/A
Cable
: N/A
Software version
: V1.0
Hardware version
: V1.0
Note
: N/A
Remark
: N/A
Frequency Range
: 105.5-204.5KHz
Note: The Lowest, middle, and the Highest frequency of channel were selected to
perform the test. The selected frequency and test software see below:
Channel
51
100
Frequency
KHz
105.5
155.5
204.5
Page 4 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
1.2 Related Submittal(s) / Grant (s)
This submittal(s) (test report) is intended for FCC ID: 2AFKNF306W filing to comply
with FCC Part 15 (2016), Subpart C Rule.
1.3 Test Methodology
Both AC mains line-conducted and radiated emission measurements were performed
according to the procedures in ANSI C63.10 (2013). Radiated emission measurement
was performed in semi-anechoic chamber and conducted emission measurement
was performed in shield room. For radiated emission measurement, preliminary scans
were performed in the semi-anechoic chamber only to determine the worst case
modes. All radiated tests were performed at an antenna to EUT distance of 3 meters.
1.4 Equipment Modifications
Not available for this EUT intended for grant.
1.5 Support Device
Adapter
(Provided by
manufacturer)
: Manufacturer: Shenzhen Good-she technology
co., ltd.
M/N: GS-551
Input: AC110-240V 50-60Hz, 0.6A Max
Output: DC 3.6-6V 3A or DC6-9V 2A or
DC9-12V 1.5A
Page 5 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
1.6 Test Facility and Location
Site Description
EMC
Lab
: Listed by CNAS, August 14, 2015
The certificate is valid until August 13, 2018
The Laboratory has been assessed and proved to
be in compliance with CNAS/CL01
The Certificate Registration Number is L5795.
Listed by A2LA, November 01, 2017
The certificate is valid until December 31, 2019
The Laboratory has been assessed and proved to
be in compliance with ISO17025
The Certificate Registration Number is 4429.01
Listed by FCC, November 06, 2017
The Designation Number is CN1214
Test Firm Registration Number: 907417
Name of Firm
Site Location
Listed by Industry Canada, June 08, 2017
The Certificate Registration Number. Is 46405-9743
: Dongguan Nore Testing Center Co., Ltd.
(Dongguan NTC Co., Ltd.)
: Building D, Gaosheng Science & Technology Park,
Zhouxi Longxi Road, Nancheng District, Dongguan
City, Guangdong Province, China
1.7 Summary of Test Results
FCC Rules
§15.35
§15.207 (a)
§15.209
Description Of Test
Uncertainty
Result
20dB Bandwidth
±1.42 x10-4%
Compliant
AC Power Conducted
Emission
±1.06dB
Compliant
Radiated Emission
±3.70dB
Compliant
Page 6 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
2. System Test Configuration
2.1 EUT Configuration
The EUT configuration for testing is installed on RF field strength measurement to
meet the Commissions requirement and operating in a manner which intends to
maximize its emission characteristics in a continuous normal application.
2.2 Special Accessories
Not available for this EUT intended for grant.
2.3 Description of test modes
The EUT has been tested under operating condition. Test program used to control the
EUT for staying in continuous transmitting and normal mode is programmed. The
Lowest, middle and highest channel were chosen for testing.
2.4 EUT Exercise
The EUT was operated in the engineering mode to fix the Tx frequency that was for
the purpose of the measurements.
Page 7 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
3. Conducted Emissions Test
3.1 Test SET-UP (Block Diagram of Configuration)
3.2 Test Condition
Test Requirement: FCC Part 15.207
Frequency Range: 150KHz ~ 30MHz
Detector: RBW 9KHz, VBW 30KHz
Operation Mode: Full Load, Half Load, Empty Load
3.3 Measurement Results
Please refer to following plots of the worst case.
Page 8 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Page 9 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Page 10 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Page 11 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Page 12 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Page 13 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Page 14 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
4. Radiated Emission Test
4.1 Test SET-UP (Block Diagram of Configuration)
4.1.1 Radiated Emission Test Set-Up, Frequency Below 30MHz
Turntable
3m
EUT
Test
Receiver
0.8 m
Ground Plane
Coaxial Cable
Page 15 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
4.1.2 Radiated Emission Test Set-Up, Frequency above 1GHz
3m
4m
Turntable
EUT
1.5m
Amplifier
Spectrum
Analyzer
4.2 Measurement Procedure
a. Blow 1GHz, the EUT was placed on the top of a rotating table 0.8 meters above the
ground at a 3 meter semi- anechoic chamber room.
b. For the radiated emission test above 1GHz:
The EUT was placed on the top of a rotating table 1.5 meters above the ground at a 3
meter full anechoic chamber room. The table was rotated 360 degrees to determine the
position of the highest radiation. Place the measurement antenna away from each area of
the EUT determined to be a source of emissions at the specified measurement distance,
while keeping the measurement antenna aimed at the source of emissions at each
frequency of significant emissions, with polarization oriented for maximum response. The
measurement antenna may have to be higher or lower than the EUT, depending on the
radiation pattern of the emission and staying aimed at the emission source for receiving
the maximum signal. The final measurement antenna elevation shall be that which
maximizes the emissions. The measurement antenna elevation for maximum emissions
shall be restricted to a range of heights of from 1 m to 4 m above the ground or reference
ground plane.
c. The EUT was set 3 meters away from the interference-receiving antenna, which was
mounted on the top of a variable-height antenna tower.
d. The height of antenna is varied from one meter to four meters above the ground to
determine the maximum value of the field strength. Both horizontal and vertical
polarizations of the antenna are set to make the measurement.
e. For each suspected emission, the EUT was arranged to its worst case and then the
antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned
from 0 degrees to 360 degrees to find the maximum reading. The test-receiver system
was set to peak detect function and specified bandwidth with maximum hold mode.
f. A Quasi-peak measurement was then made for that frequency point for below 1GHz test.
PK and AV for above 1GHz emission test.
Page 16 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
During the radiated emission test, the spectrum analyzer was set with the following
configurations:
Frequency Band
Level
Resolution Bandwidth
Video Bandwidth
(MHz)
30 to 1000
QP
120 kHz
300 kHz
Peak
1 MHz
3 MHz
Above 1000
Average
1 MHz
10 Hz
4.3 Limit
Frequency range
MHz
0.009 ~ 0.490
0.490 ~ 1.705
1.705 ~ 30
30 ~ 88
88 ~ 216
216 ~ 960
Above 960
Distance Meters
300
30
30
Field Strengths Limit (15.209)
V/m
2400/F(kHz)
24000/F(kHz)
30
100
150
200
500
Remark:(1) Emission level (dB)V = 20 log Emission level V/m
(2) The smaller limit shall apply at the cross point between two
frequency bands.
(3) As shown in 15.35(b), for frequencies above 1000MHz, the
field strength limits are based on average detector, however,
the peak field strength of any emission shall not exceed the
maximum permitted average limits, specified above by more
than 20dB under any condition of modulation.
(4) The frequency range scanned is from the lowest radio
frequency signal generated in the device which is greater than
9 kHz to the tenth harmonic of the highest fundamental
frequency or 40 GHz, whichever is lower.
Page 17 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Receiver Parameter
Attenuation
Start ~ Stop Frequency
Setting
Auto
9KHz~90KHz/ RB 200Hz for AV
90KHz~110KHz/ RB 200Hz for QP
110KHz~490KHz/ RB 200Hz for AV
490KHz~30MHz/ RB 9KHz for QP
30MHz~1000MHz/ RB 120KHz for QP
FCC 15.209 (d) The emission limits shown in the above table are based on
measurements employing a CISPR quasi-peak detector except for the frequency bands
9-90KHz, 110-490KHz and above 1000MHz. Radiated emission limits in these three
bands are based on measurements employing an average detector.
4.4 Measurement Results
Please refer to following plots of the worst case: Full Load.
Page 18 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Note: When the PEAK level was below the limit of AV level, the AV levels were considered to
meet the requirements.
Page 19 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Note: When the PEAK level was below the limit of AV level, the AV levels were considered to
Page 20 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
meet the requirements.
Note: When the PEAK level was below the limit of AV level, the AV levels were considered to
Page 21 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
meet the requirements.
Note: When the PEAK level was below the limit of AV level, the AV levels were considered to
meet the requirements.
Page 22 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Page 23 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Page 24 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Note: When the PEAK level was below the limit of AV level, the AV levels were considered to
meet the requirements.
Page 25 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Note: When the PEAK level was below the limit of AV level, the AV levels were considered to
meet the requirements.
Page 26 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Page 27 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Page 28 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Page 29 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Page 30 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Note: When the PEAK level was below the limit of AV level, the AV levels were considered to
meet the requirements.
Page 31 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Note: When the PEAK level was below the limit of AV level, the AV levels were considered to
meet the requirements.
Page 32 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Page 33 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Page 34 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Page 35 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Page 36 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
5. 20dB Bandwidth
5.1 Measurement Procedure
Maximum 20dB RF Bandwidth, FCC Rule 15.35:
The antenna port of the EUT was connected to the input of a spectrum analyzer.
Analyzer RBW was chosen so that the display was a result of the hopping channel
modulation. For each RF output channel investigated, the spectrum analyzer center
frequency was set to the channel carrier. Use the spectrum 20dB down delta
function to measure the bandwidth.
5.2 Test SET-UP (Block Diagram of Configuration)
EUT
Spectrum Analyzer
5.3 Measurement Results
Refer to attached data chart.
RBW:
Test By:
Temperature :
Test Result:
30Hz
Sance
24 ℃
PASS
VBW:
Spectrum Detector:
Test Date :
Humidity :
100Hz
PK
November 27, 2017
50 %
Channel frequency (KHz)
20dB Down BW(Hz)
105.5
155.5
204.5
78.33
78.53
78.53
Page 37 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Lowest Channel
* RBW 30 Hz
* VBW 100 Hz
Ref
100 dBµV
* Att
30 dB
SWT 560 ms
ndB [T1]
20.00 dB
BW 79.326923077 Hz
Temp 1 [T1 ndB]
49.82 dBµV
105.460737179 kHz
Temp 2 [T1 ndB]
50.25 dBµV
105.540064103 kHz
100
90
1 PK
MAXH
Marker 1 [T1 ]
70.16 dBµV
105.500000000 kHz
80
70
TDF
60
T2
T1
50
40
30
20
10
Center
105.5 kHz
Date: 27.NOV.2017
50 Hz/
Span
500 Hz
17:05:51
Middle Channel
* RBW 30 Hz
* VBW 100 Hz
Ref
100 dBµV
* Att
30 dB
SWT 560 ms
ndB [T1]
20.00 dB
BW 78.525641026 Hz
Temp 1 [T1 ndB]
53.21 dBµV
155.460737179 kHz
Temp 2 [T1 ndB]
53.77 dBµV
155.539262821 kHz
100
90
1 PK
MAXH
Marker 1 [T1 ]
73.45 dBµV
155.500000000 kHz
80
70
TDF
60
T2
T1
50
40
30
20
10
Center
155.5 kHz
Date: 27.NOV.2017
50 Hz/
Span
500 Hz
17:06:25
Page 38 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
Highest Channel
* RBW 30 Hz
* VBW 100 Hz
Ref
100 dBµV
* Att
30 dB
SWT 560 ms
ndB [T1]
20.00 dB
BW 78.525641026 Hz
Temp 1 [T1 ndB]
50.98 dBµV
204.461538462 kHz
Temp 2 [T1 ndB]
51.13 dBµV
204.540064103 kHz
100
90
1 PK
MAXH
Marker 1 [T1 ]
70.77 dBµV
204.500000000 kHz
80
70
TDF
60
T2
T1
50
40
30
20
10
Center
204.5 kHz
Date: 27.NOV.2017
50 Hz/
Span
500 Hz
17:07:29
Page 39 of 40
Dongguan Nore Testing Center Co., Ltd.
Report No.: NTC1711180FV00
FCC ID: 2AFKNF306W
6. Test Equipment List
Description
Manufacturer
Model Number
Serial
Number
Characteristics
Test Receiver
Rohde & Schwarz
ESCI7
100837
9KHz~7GHz
Mar. 14, 2017 Mar. 13, 2018
Antenna
Schwarzbeck
VULB9162
9162-010
30MHz~7GHz
Mar. 15, 2017 Mar. 14, 2018
Cable
Huber+Suhner
CBL2-NN-1M
22390001
9KHz~7GHz
Mar. 14, 2017 Mar. 13, 2018
Cable
Huber+Suhner
CIL02
N/A
9KHz~7GHz
Mar. 14, 2017 Mar. 13, 2018
RF Cable
Huber+Suhner
SF-104
MY16559/4
9KHz~25GHz
Apr. 25, 2017 Apr. 25, 2018
Power Amplifier
HP
HP 8447D
Horn Antenna
Schwarzbeck
BBHA9170
9170-242
15GHz~40GHz
Mar. 14, 2017 Mar. 13, 2018
Horn Antenna
Com-Power
AH-118
071078
1GHz~18GHz
Mar. 15, 2017 Mar. 14, 2018
RF Cable
Huber+Suhner
SF-104
N/A
9KHz~40GHz
Apr. 25, 2017 Apr. 24, 2018
Loop antenna
Schwarzbeck
FMZB1513
1513-272
9KHz~30MHz
Sep. 09, 2017 Sep. 08, 2018
Rohde & Schwarz
FSU26
200409/026
20Hz~26.5GHz
Apr. 25, 2017 Apr. 24, 2018
Rohde & Schwarz
FSV40
101003
10Hz~40GHz
April. 06, 2017 April. 05, 2018
Pre-Amplifier
EMCI
EMC 184045
980102
18GHz~40GHz
Nov. 03, 2017 Nov. 02, 2018
Pre-Amplifier
Agilent
8449B
L.I.S.N.
Rohde & Schwarz
ENV 216
101317
9KHz~30MHz
Temporary
antenna
connector
TESCOM
SS402
N/A
9KHz-25GHz
Spectrum
Analyzer
Spectrum
Analyzer
Calibration
Date
Calibration
Due Date
1145A00203 100KHz~1.3GHz Mar. 14, 2017 Mar. 13, 2018
3008A02964 1GHz~26.5GHz Apr. 25, 2017 Apr. 24, 2018
Mar. 14, 2017 Mar. 13, 2018
N/A
N/A
Note: The temporary antenna connector is soldered on the PCB board in order to perform
conducted tests and this temporary antenna connector is listed in the equipment list.
---End--Page 40 of 40
Download: F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Mirror Download [FCC.gov]F306W Fast Wireless Charger Test Report 14_F306W TestRpt r1 Spigen Korea Co., Ltd.
Document ID3704872
Application IDh1op8biJYo+bvnJ9T5QtuA==
Document Description14_F306W TestRpt r1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize446.03kB (5575416 bits)
Date Submitted2018-01-08 00:00:00
Date Available2018-01-08 00:00:00
Creation Date2018-01-02 16:52:54
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2018-01-02 16:59:01
Document Title14_F306W TestRpt r1
Document CreatorPScript5.dll Version 5.2.2
Document Author: Rose

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Author                          : Rose
Create Date                     : 2018:01:02 16:52:54+08:00
Modify Date                     : 2018:01:02 16:59:01+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Title                           : Microsoft Word - NTC1711180FV00 华功Fast wireless charger 2AFKNF306 FCC ID
Creator                         : Rose
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2018:01:02 16:59:01+08:00
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Document ID                     : uuid:5bed63e0-b603-4443-8dc2-e9eb7e20a4b3
Instance ID                     : uuid:3f980d59-2680-43fa-99ec-aca218a2a1ba
Page Count                      : 40
EXIF Metadata provided by EXIF.tools

Facebook Twitter Google+ RSS © FCCID.io 2018