FCC ID 2AIZN-X1103

XPAD 30 Pro

by INFINIX MOBILITY LIMITED

Grantee Code: 2AIZN   Product Code: X1103
Latest application date: 2026-05-27

FCC ID Device Details

FCC ID2AIZN-X1103
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AIZN
Product CodeX1103
Applicant BusinessINFINIX MOBILITY LIMITED
Related Domains infinixmobility.com picus.fi
Equipment ClassXPAD 30 Pro
Test FirmShanghai Tejet Communications Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5745-5825 MHzOriginal Equipment2026-05-27
2402-2480 MHzOriginal Equipment2026-05-27
2572.5-2617.5 MHzOriginal Equipment2026-05-27
2412-2462 MHzOriginal Equipment2026-05-27

Exhibits

DocumentTypeAvailableFile
ID Label/Location InfoID Label/Location Info2026-05-27PDF 649.8 KB
Antenna SpecificationTest Report2026-05-27PDF 5 MB
Test Report_BLETest Report2026-05-27PDF 4.6 MB
Test Report_DFSTest Report2026-05-27PDF 1.7 MB
Test Report_DSS_Part 1Test Report2026-05-27PDF 3.1 MB
Test Report_DSS_Part 2Test Report2026-05-27PDF 3.5 MB
Test Report_JBPTest Report2026-05-27PDF 1.4 MB
Test Report_NIITest Report2026-05-27PDF 1.2 MB
Test Report_NII_Data Part 1Test Report2026-05-27PDF 2.9 MB
Test Report_NII_Data Part 2Test Report2026-05-27PDF 927.1 KB
Test Report_NII_Data Part 3Test Report2026-05-27PDF 2.9 MB
Test Report_NII_Data Part 4Test Report2026-05-27PDF 1.8 MB
Test Report_NII_Data Part 5Test Report2026-05-27PDF 1.6 MB
Test Report_PCBTest Report2026-05-27PDF 789.3 KB
Test Report_PCB_Data Part 1Test Report2026-05-27PDF 445.8 KB
Test Report_PCB_Data Part 2-1Test Report2026-05-27PDF 3.6 MB
Test Report_PCB_Data Part 2-2Test Report2026-05-27PDF 4 MB
Test Report_PCB_Data Part 2-3Test Report2026-05-27PDF 3.9 MB
Test Report_PCB_Data Part 3-1Test Report2026-05-27PDF 3.3 MB
Test Report_PCB_Data Part 3-2Test Report2026-05-27PDF 3.9 MB
Test Report_PCB_Data Part 3-3Test Report2026-05-27PDF 3.8 MB
Test Report_PCB_Data Part 3-4Test Report2026-05-27PDF 3.9 MB
Test Report_PCB_Data Part 3-5Test Report2026-05-27PDF 3.9 MB
Test Report_PCB_Data Part 3-6Test Report2026-05-27PDF 3.8 MB
Test Report_PCB_Data Part 4Test Report2026-05-27PDF 723 KB
Test Report_PCB_Data Part 5-1Test Report2026-05-27PDF 3 MB
Test Report_PCB_Data Part 5-2Test Report2026-05-27PDF 3.6 MB
Test Report_PCB_Data Part 5-3Test Report2026-05-27PDF 3.9 MB
Test Report_PCB_Data Part 5-4Test Report2026-05-27PDF 3.8 MB
Test Report_PCB_Data Part 5-5Test Report2026-05-27PDF 3.7 MB
Test Report_PCB_Data Part 5-6Test Report2026-05-27PDF 3.9 MB
Test Report_PCB_Data Part 5-7Test Report2026-05-27PDF 4 MB
Test Report_PCB_Data Part 6-1Test Report2026-05-27PDF 2.8 MB
Test Report_PCB_Data Part 6-2Test Report2026-05-27PDF 4 MB
Test Report_PCB_Data Part 6-3Test Report2026-05-27PDF 4 MB
Test Report_PCB_Data Part 6-4Test Report2026-05-27PDF 4.1 MB
Test Report_PCB_Data Part 6-5Test Report2026-05-27PDF 4.1 MB
Test Report_PCB_Data Part 6-6Test Report2026-05-27PDF 4.4 MB
Test Report_PCB_Data Part 6-7Test Report2026-05-27PDF 4.1 MB
Test Report_PCB_Data Part 6-8Test Report2026-05-27PDF 3.7 MB
Test Report_PCB_Data Part 7Test Report2026-05-27PDF 3.4 MB
Test Report_SARRF Exposure Info2026-05-27PDF 2.1 MB
Test Report_WLANTest Report2026-05-27PDF 5.8 MB
Test Report_WLAN_Data Part 1Test Report2026-05-27PDF 592.9 KB
Test Report_WLAN_Data Part 2Test Report2026-05-27PDF 549.6 KB
Attestation StatementsAttestation Statements2026-05-27PDF 116.8 KB
US Agent LetterAttestation Statements2026-05-27PDF 155.3 KB
Authorization letterCover Letter(s)2026-05-27PDF 79.2 KB
confidentialityCover Letter(s)2026-05-27PDF 80.6 KB
Ti-CC26040079-AC Calibration reportRF Exposure Info2026-05-27PDF 4.5 MB
Ti-CC26040079-AP Power ListRF Exposure Info2026-05-27PDF 1.1 MB
Ti-CC26040079-ASC System CheckRF Exposure Info2026-05-27PDF 454 KB
Ti-CC26040079-ATD Test DataRF Exposure Info2026-05-27PDF 740.9 KB
Users Manual Metadata onlyUsers Manual2026-11-23PDF 665 KB
Internal Photos Metadata onlyInternal Photos2026-11-23PDF 2 MB
External Photos Metadata onlyExternal Photos2026-11-23PDF 1.5 MB
Test Setup Photos Metadata onlyTest Setup Photos2026-11-23PDF 685 KB
Test Setup Photos_RF Metadata onlyTest Setup Photos2026-11-23PDF 663.1 KB
Test Setup Photos_RF Metadata onlyTest Setup Photos2026-11-23PDF 1 MB
Test Setup Photos_SAR Metadata onlyTest Setup Photos2026-11-23PDF 394.4 KB
Block Diagram Metadata onlyBlock DiagramPDF 162.6 KB
Schematics_1 Metadata onlySchematicsPDF 3.1 MB
Schematics_2 Metadata onlySchematicsPDF 99.6 KB
NII Software Security Info Metadata onlyOperational DescriptionPDF 141.6 KB
Operational Description Metadata onlyOperational DescriptionPDF 117.3 KB
Part list (BOM) Metadata onlyParts List/Tune Up InfoPDF 167.3 KB
Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 1.1 MB

Application Information

Application IDNczNXcj9fPftAuUDrzQj1Q==
Final Action Date2026-05-27
Application PurposeOriginal Equipment
Applicant FRN0025707605
ModelX1103
Frequency Range5745-5825 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionXPAD 30 Pro
Responsible PartyJerry Liu, jerry.liu@infinixmobility.com , +86-0755-61803856
Technical ContactXuewen Wu, Shenzhen BALUN Technology Co., Ltd, cbproject@baluntek.com , 86-755-66850100
Non-Technical ContactIvan Wang, Picus Advisors US LLC, ivan.wang@picus.fi , 512-806-9158
Test FirmCarol Duan, Shanghai Tejet Communications Technology Co., Ltd., xiaohong.duan@titcgroup.com , 86-021-58180736
TCB Emaildl_radio-certification@kiwa.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
NczNXcj9fPftAuUDrzQj1Q==2026-05-27Original Equipment
HeUulENpFjEggpzFzZ1AbA==2026-05-27Original Equipment
G9hoF8L7GrK9CGp4jp5k0w==2026-05-27Original Equipment
8tm6wOZx4EmY7oNleqW13A==2026-05-27Original Equipment
4HWuFD7kFmUpzxyrLHMlkg==2026-05-27Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
5180-5240 MHz0.006715ECC
5260-5320 MHz0.006215ECC ND
5500-5700 MHz0.006315ECC ND
5745-5825 MHz0.006115ECC
2402-2480 MHz0.0315CCC
824.2-848.8 MHz0.0482.5 PM248KGXW22H
824.2-848.8 MHz0.1042.5 PM258KG7W22H
1850.2-1909.8 MHz0.0412.5 PM248KGXW24E
1850.2-1909.8 MHz0.4612.5 PM248KG7W24E
1852.4-1907.6 MHz0.0072.5 PM4M14F9W24E
1712.4-1752.6 MHz0.0062.5 PM4M14F9W27
826.4-846.6 MHz0.0052.5 PM4M16F9W22H
1850.7-1909.3 MHz0.0092.5 PM17M9G7D24E
1850.7-1909.3 MHz0.0082.5 PM17M9W7D24E
1710.7-1754.3 MHz0.0062.5 PM17M9G7D27
1710.7-1754.3 MHz0.0062.5 PM17M9W7D27
824.7-848.3 MHz0.0052.5 PM8M96G7D22H
824.7-848.3 MHz0.0052.5 PM8M97W7D22H
2502.5-2567.5 MHz0.0092.5 PM17M9G7D27
2502.5-2567.5 MHz0.0082.5 PM17M9W7D27
699.7-715.3 MHz0.0032.5 PM8M96G7D27
699.7-715.3 MHz0.0022.5 PM8M96W7D27
779.5-784.5 MHz0.0032.5 PM8M95G7D27
779.5-784.5 MHz0.0032.5 PM8M96W7D27
706.5-713.5 MHz0.0022.5 PM8M96G7D27
706.5-713.5 MHz0.0022.5 PM8M95W7D27
824.7-848.3 MHz0.0052.5 PM13M5G7D22H
824.7-848.3 MHz0.0052.5 PM13M5W7D22H
824.7-848.3 MHz0.0062.5 PM8M96G7D22H
814.7-823.3 MHz0.0052.5 PM8M99G7D90
814.7-823.3 MHz0.0052.5 PM8M99W7D90
2572.5-2617.5 MHz0.0142.5 PM17M9G7D27
2572.5-2617.5 MHz0.0122.5 PM17M9W7D27
2498.5-2687.5 MHz0.0142.5 PM17M9G7D27
2498.5-2687.5 MHz0.0122.5 PM17M9W7D27
1710.7-1779.3 MHz0.0112.5 PM17M9G7D27
1710.7-1779.3 MHz0.012.5 PM17M9W7D27
2402-2480 MHz0.02915CCC
2412-2462 MHz0.1115CCC
15BCC

Grants

TCB Grant - Application NczNXcj9fPftAuUDrzQj1Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 05/27/2026

Application Dated: 05/26/2026
INFINIX MOBILITY LIMITED
FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL
CENTRE 19-25 SHAN MEI STREET FOTAN
NT,
Hong Kong
 
Attention: Jerry Liu ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIZN-X1103
Name of Grantee:  INFINIX MOBILITY LIMITED
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: XPAD 30 Pro
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0067  
CC ND 15E 5260.0  -  5320.0 0.0062  
CC ND 15E 5500.0  -  5700.0 0.0063  
CC 15E 5745.0  -  5825.0 0.0061  

Power Output is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.51 W/kg and 1.44 W/kg, respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application HeUulENpFjEggpzFzZ1AbA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 05/27/2026

Application Dated: 05/26/2026
INFINIX MOBILITY LIMITED
FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL
CENTRE 19-25 SHAN MEI STREET FOTAN
NT,
Hong Kong
 
Attention: Jerry Liu ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIZN-X1103
Name of Grantee:  INFINIX MOBILITY LIMITED
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: XPAD 30 Pro
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.03  

Power Output is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.29 W/kg and 1.45 W/kg, respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application G9hoF8L7GrK9CGp4jp5k0w==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 05/27/2026

Application Dated: 05/26/2026
INFINIX MOBILITY LIMITED
FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL
CENTRE 19-25 SHAN MEI STREET FOTAN
NT,
Hong Kong
 
Attention: Jerry Liu ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIZN-X1103
Name of Grantee:  INFINIX MOBILITY LIMITED
Equipment Class: PCS Licensed Transmitter
Notes: XPAD 30 Pro
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.048 2.5  PM 248KGXW
22H 824.2  -  848.8 0.104 2.5  PM 258KG7W
24E 1850.2  -  1909.8 0.041 2.5  PM 248KGXW
24E 1850.2  -  1909.8 0.461 2.5  PM 248KG7W
24E 1852.4  -  1907.6 0.007 2.5  PM 4M14F9W
27 1712.4  -  1752.6 0.006 2.5  PM 4M14F9W
22H 826.4  -  846.6 0.005 2.5  PM 4M16F9W
24E 1850.7  -  1909.3 0.009 2.5  PM 17M9G7D
24E 1850.7  -  1909.3 0.008 2.5  PM 17M9W7D
27 1710.7  -  1754.3 0.006 2.5  PM 17M9G7D
27 1710.7  -  1754.3 0.006 2.5  PM 17M9W7D
22H 824.7  -  848.3 0.005 2.5  PM 8M96G7D
22H 824.7  -  848.3 0.005 2.5  PM 8M97W7D
27 2502.5  -  2567.5 0.009 2.5  PM 17M9G7D
27 2502.5  -  2567.5 0.008 2.5  PM 17M9W7D
27 699.7  -  715.3 0.003 2.5  PM 8M96G7D
27 699.7  -  715.3 0.002 2.5  PM 8M96W7D
27 779.5  -  784.5 0.003 2.5  PM 8M95G7D
27 779.5  -  784.5 0.003 2.5  PM 8M96W7D
27 706.5  -  713.5 0.002 2.5  PM 8M96G7D
27 706.5  -  713.5 0.002 2.5  PM 8M95W7D
22H 824.7  -  848.3 0.005 2.5  PM 13M5G7D
22H 824.7  -  848.3 0.005 2.5  PM 13M5W7D
22H 824.7  -  848.3 0.006 2.5  PM 8M96G7D
90 814.7  -  823.3 0.005 2.5  PM 8M99G7D
90 814.7  -  823.3 0.005 2.5  PM 8M99W7D
27 2572.5  -  2617.5 0.014 2.5  PM 17M9G7D
27 2572.5  -  2617.5 0.012 2.5  PM 17M9W7D
27 2498.5  -  2687.5 0.014 2.5  PM 17M9G7D
27 2498.5  -  2687.5 0.012 2.5  PM 17M9W7D
27 1710.7  -  1779.3 0.011 2.5  PM 17M9G7D
27 1710.7  -  1779.3 0.01 2.5  PM 17M9W7D

Output power is ERP for Part 22, Part 27 and Part 90; EIRP for Part 24 and Part 27. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.67 W/kg and 1.45 W/kg, respectively.

TCB Grant - Application 8tm6wOZx4EmY7oNleqW13A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 05/27/2026

Application Dated: 05/26/2026
INFINIX MOBILITY LIMITED
FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL
CENTRE 19-25 SHAN MEI STREET FOTAN
NT,
Hong Kong
 
Attention: Jerry Liu ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIZN-X1103
Name of Grantee:  INFINIX MOBILITY LIMITED
Equipment Class: Digital Transmission System
Notes: XPAD 30 Pro
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.029  
CC 15C 2412.0  -  2462.0 0.11  

Power Output is conducted. This is a portable device. The SAR data in this filing is applicable to demonstrate compliance for body operating conditions and is limited to the specific configuration tested for this filling. SAR has been evaluated at 0 mm. The highest reported SAR values for body and simultaneous transmission use conditions are 0.52 W/kg and 1.45 W/kg, respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application 4HWuFD7kFmUpzxyrLHMlkg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Kiwa Nederland B.V.
Wilmersdorf 50
Apeldoorn, NL-7300 AC
Netherlands
Date of Grant: 05/27/2026

Application Dated: 05/26/2026
INFINIX MOBILITY LIMITED
FLAT N 16/F BLOCK B UNIVERSAL INDUSTRIAL
CENTRE 19-25 SHAN MEI STREET FOTAN
NT,
Hong Kong
 
Attention: Jerry Liu ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AIZN-X1103
Name of Grantee:  INFINIX MOBILITY LIMITED
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: XPAD 30 Pro
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.