XIR CONSOLE Test Report JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.

JOHNSON INDUSTRIES (SHANGHAI) CO., LTD. CONSOLE

Page 1 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 2 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 3 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 4 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 5 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 6 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 7 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 8 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 9 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 10 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 11 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 12 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 13 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 14 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 15 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 16 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 17 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 18 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 19 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 20 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 21 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 22 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 23 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 24 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 25 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 26 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 27 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 28 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 29 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 30 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 31 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 32 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 33 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 34 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 35 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 36 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 37 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 38 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 39 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 40 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 41 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 42 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 43 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 44 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 45 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 46 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 47 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 48 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 49 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 50 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 51 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 52 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 53 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 54 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 55 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 56 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 57 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 58 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 59 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 60 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 61 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 62 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 63 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 64 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Page 65 of XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.

Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 1 of 137
TEST REPORT
On behalf of
Johnson Industries (Shanghai) Co., Ltd.
Product Name: Console
Model No.: XIR
FCC ID: 2AOTTXIR
Prepared For: Johnson Industries (Shanghai) Co., Ltd.
A1 No.4500 Baoqian Road, Zhuqiao Town, Jiading District,
Shanghai
Prepared By: Audix Technology (Shanghai) Co., Ltd.
3F and 4F, 34Bldg, 680 Guiping Rd., Caohejing Hi-Tech
Park, Shanghai 200233, China
Tel: +86-21-64955500
Fax: +86-21-64955491
TESTING
NVLAP LAB CODE 200371-0
File No.
Report No.
Date of Test
Date of Report
AOE-008585
ACI-F18102
2018.03.24 - 30
2018.04.02
The statement is based on a single evaluation of one sample of the above-mentioned products. It does not
imply an assessment of the whole production and does not permit the use of the test lab logo.
The report must not be used by the client to claim product certification, approval, or endorsement by
NVLAP, NIST, or any agency of the Federal Government.
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 2 of 137
TABLE OF CONTENTS
Page
1 SUMMARY OF STANDARDS AND RESULTS .......................................................................... 5
1.1 Description of Standards and Results ......................................................................................... 5
2 GENERAL INFORMATION.......................................................................................................... 6
2.1 Description of Equipment Under Test........................................................................................ 6
2.2 Description of Test Facility ........................................................................................................ 7
2.3 Measurement Uncertainty .......................................................................................................... 7
3 CONDUCTED EMISSION MEASUREMENT ............................................................................ 8
3.1 Test Equipment........................................................................................................................... 8
3.2 Block Diagram of Test Setup ..................................................................................................... 8
3.3 Conducted Emission Limits (§15.207) ....................................................................................... 8
3.4 Operating Condition of EUT ...................................................................................................... 9
3.5 Test Procedures .......................................................................................................................... 9
3.6 Test Results ................................................................................................................................ 9
4 RADIATED EMISSION MEASUREMENT ............................................................................... 15
4.1 Test Equipment......................................................................................................................... 15
4.2 Block Diagram of Test Setup ................................................................................................... 15
4.3 Radiated Emission Limit (§15.209) ......................................................................................... 16
4.4 Test Configuration .................................................................................................................... 16
4.5 Operating Condition of EUT .................................................................................................... 17
4.6 Test Procedures ........................................................................................................................ 17
4.7 Test Results .............................................................................................................................. 18
5 20 DB BANDWIDTH MEASUREMENT .................................................................................... 38
5.1 Test Equipment......................................................................................................................... 38
5.2 Block Diagram of Test Setup ................................................................................................... 38
5.3 Specification Limits (§15.247(a)(1)) ........................................................................................ 38
5.4 Operating Condition of EUT .................................................................................................... 38
5.5 Test Procedure .......................................................................................................................... 38
5.6 Test Results .............................................................................................................................. 39
6 CARRIER FREQUENCY SEPARATION MEASUREMENT ................................................. 49
6.1 Test Equipment......................................................................................................................... 49
6.2 Block Diagram of Test Setup ................................................................................................... 49
6.3 Specification Limits (§15.247(a)(1)) ........................................................................................ 49
6.4 Operating Condition of EUT .................................................................................................... 49
6.5 Test Procedure .......................................................................................................................... 49
6.6 Test Results .............................................................................................................................. 50
7 NUMBER OF HOPPING FREQUENCIES MEASUREMENT ............................................... 60
7.1 Test Equipment......................................................................................................................... 60
7.2 Block Diagram of Test Setup ................................................................................................... 60
7.3 Specification Limits (§15.247(a)(1)(iii)) .................................................................................. 60
7.4 Operating Condition of EUT .................................................................................................... 60
7.5 Test Procedure .......................................................................................................................... 60
7.6 Test Results .............................................................................................................................. 61
8 DWELL TIME MEASUREMENT............................................................................................... 65
8.1 Test Equipment......................................................................................................................... 65
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 3 of 137
8.2 Block Diagram of Test Setup ................................................................................................... 65
8.3 Specification Limits (§15.247(a)(1)(iii)) .................................................................................. 65
8.4 Operating Condition of EUT .................................................................................................... 65
8.5 Test Procedure .......................................................................................................................... 65
8.6 Test Results .............................................................................................................................. 66
9 MAXIMUM PEAK OUTPUT POWER MEASUREMENT ...................................................... 73
9.1 Test Equipment......................................................................................................................... 73
9.2 Block Diagram of Test Setup ................................................................................................... 73
9.3 Specification Limits (§15.247(b)(1)) ....................................................................................... 73
9.4 Operating Condition of EUT .................................................................................................... 73
9.5 Test Procedure .......................................................................................................................... 73
9.6 Test Results .............................................................................................................................. 74
10 BAND EDGE MEASUREMENT ................................................................................................. 84
10.1 Test Equipment......................................................................................................................... 84
10.2 Block Diagram of Test Setup ................................................................................................... 84
10.3 Specification Limits (§15.247(d)) ............................................................................................ 84
10.4 Operating Condition of EUT .................................................................................................... 84
10.5 Test Procedure .......................................................................................................................... 84
10.6 Test Results .............................................................................................................................. 86
11 EMISSION LIMITATIONS MEASUREMENT......................................................................... 99
11.1 Test Equipment......................................................................................................................... 99
11.2 Block Diagram of Test Setup ................................................................................................... 99
11.3 Specification Limits (§15.247(d)) ............................................................................................ 99
11.4 Operating Condition of EUT .................................................................................................... 99
11.5 Test Procedure .......................................................................................................................... 99
11.6 Test Results ............................................................................................................................ 100
12 DEVIATION TO TEST SPECIFICATIONS ............................................................................ 137
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
Page 4 of 137
FCC ID: 2AOTTXIR
TEST REPORT
Applicant
EUT Description :
Johnson Industries (Shanghai) Co., Ltd.
Console
(A) Model No.
(B) Power Supply
(C) Test Voltage
Refer to Sec.2.1
AC 120V/60Hz (via adapter)
AC 120V/60Hz (via adapter)
Test Procedure Used:
FCC RULES AND REGULATIONS PART 15 SUBPART C
AND ANSI C63.10-2013 AND FCC PUBILC NOTICE DA 00-705, Mar.2000
The device described above is tested by Audix Technology (Shanghai) Co., Ltd. to
determine the maximum emission levels emanating from the device. The maximum
emission levels are compared to the FCC Part 15 Subpart C limits.
The test results are contained in this test report and Audix Technology (Shanghai) Co.,
Ltd. is assumed full responsibility for the accuracy and completeness of these
measurements. This report also shows that the EUT to be technically compliance with
the FCC limits.
This report applies to above tested Sample only. This report shall not be reproduced in
part without written approval of Audix Technology (Shanghai) Co., Ltd.
Date of Test :
2018.03.24 - 30
Date of Report :
2018.04.02
Producer :
JAREY LU / Supervisor
Reviewer :
BYRON WU / Deputy Assistant Manager
Signatory :
BYRON KWO/Assistant General Manager
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
Page 5 of 137
FCC ID: 2AOTTXIR
1 SUMMARY OF STANDARDS AND RESULTS
1.1
Description of Standards and Results
The EUT have been tested according to the applicable standards as referenced
below:
Description / Test Item
Test Standard
Results
Meets Limit
EMISSION
Conducted Emission
Measurement
FCC Rules And Regulations Part 15 Subpart C
And ANSI C63.10:2013
And FCC Public Notice DA 00-705, Mar.2000
Pass
15.207
Radiated Emission
Measurement
FCC Rules And Regulations Part 15 Subpart C
And ANSI C63.10:2013
And FCC Public Notice DA 00-705, Mar.2000
Pass
15.209(a)
15.205(a)(c)
20 dB Bandwidth
Measurement
FCC Rules And Regulations Part 15 Subpart C
And ANSI C63.10:2013
And FCC Public Notice DA 00-705, Mar.2000
Pass
15.247(a)(1)
Carrier Frequency
Separation
Measurement
FCC Rules And Regulations Part 15 Subpart C
And ANSI C63.10:2013
And FCC Public Notice DA 00-705, Mar.2000
Pass
15.247(a)(1)
Number of Hopping
Frequencies
Measurement
FCC Rules And Regulations Part 15 Subpart C
And ANSI C63.10:2013
And FCC Public Notice DA 00-705, Mar.2000
Pass
15.247(a)(1)(iii)
Dwell Time
Measurement
FCC Rules And Regulations Part 15 Subpart C
And ANSI C63.10:2013
And FCC Public Notice DA 00-705, Mar.2000
Pass
15.247(a)(1)(iii)
Maximum Peak Output
Power Measurement
FCC Rules And Regulations Part 15 Subpart C
And ANSI C63.10:2013
And FCC Public Notice DA 00-705, Mar.2000
Pass
15.247(b)(1)
Band Edge
Measurement
FCC Rules And Regulations Part 15 Subpart C
And ANSI C63.10:2013
And FCC Public Notice DA 00-705, Mar.2000
Pass
15.247(d)
Emission Limitations
Measurement
FCC Rules And Regulations Part 15 Subpart C
And ANSI C63.10:2013
And FCC Public Notice DA 00-705, Mar.2000
Pass
15.247(d)
N/A is an abbreviation for Not Applicable.
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
Page 6 of 137
FCC ID: 2AOTTXIR
2 GENERAL INFORMATION
2.1 Description of Equipment Under Test
Description
Console
Type of EUT
; Production
Pre-product
Pro-type
Model Number :
XIR
RF Module
AP6210 + WLT2564M
Note
Contains FCC ID: 2AKDB-WLT2564M
Test RF Module :
AP6210
Radio Tech
IEEE 802.11b/g/n + BT 4.0
Test Tech
BT 4.0
Channel Freq.
2402MHz - 2480MHz
Tested Freq.
2402MHz, 2441MHz, 2480MHz
Modulation
FHSS,GFSK,DPSK,DQPSK
Antenna Type
SMA interface Small antenna(Cu)
Note: According to KDB 353028 D01 A 2) b) ii) (3)
antenna connector comply with 15.203
Connector Type :
SMA Connector
Antenna Gain
2 dBi
Test Mode
The EUT was set at continuous TX with duty cycle
100% during all the test in the report
Applicant
Johnson Industries (Shanghai) Co., Ltd.
A1 No.4500 Baoqian Road, Zhuqiao Town, Jiading
District, Shanghai
Manufacturer
same as Applicant
Factory
same as Applicant
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
2.2
FCC ID: 2AOTTXIR
Page 7 of 137
Description of Test Facility
Name of Firm
: Audix Technology (Shanghai) Co., Ltd.
Site Location
: 3F and 4F, 34Bldg, 680 Guiping Rd.,
Caohejing Hi-Tech Park,
Shanghai 200233, China.
Accredited by NVLAP, Lab Code
: 200371-0
FCC Designation Number
: CN5027
Test Firm Registration Number
: 954668
2.3 Measurement Uncertainty
Conducted Disturbance Expanded Uncertainty (0.15-30MHz):
U = 3.4dB
Radiated Emission Expanded Uncertainty (30-1000MHz):
U = 3.99dB
Radiated Emission Expanded Uncertainty (1000M-26.5GHz):
U = 4.98dB
6 dB Bandwidth Expanded Uncertainty
: U = 6x10-8 MHz
Maximum Peak Output Power Expanded Uncertainty
: U = 0.84 dB
Power Spectral Density Expanded Uncertainty
: U = 0.38 dB
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
Page 8 of 137
FCC ID: 2AOTTXIR
3 CONDUCTED EMISSION MEASUREMENT
3.1
Test Equipment
The following test equipment are used during the conducted emission test in a
shielded room.
Item
Type
Manufacturer
Model No. Serial No.
Last Cal.
Next Cal.
1.
Test Receiver
R&S
ESCI
101302
Apr 27, 2017 Apr 26, 2018
Artificial Mains
2.
R&S
ENV4200
100125
Jun 24, 2017 Jun 23, 2018
Network (AMN)
3.
Software
Audix
E3
6.2009-1-15
---
3.2
Block Diagram of Test Setup
TEST RECEIVER
TEST PC SYSTEM
AC POWER
SOURCE
TRANSFORMER
EUT
AMN
LISN
PERIPHERALS
: Signal Line
: Power Line
: 50 ohm Terminator
3.3
Conducted Emission Limits (§15.207)
Frequency
(MHz)
0.15 ~ 0.5
0.5 ~ 5
5 ~ 30
Conducted limits (dbμV)
Quasi-peak
Average
66 to 56 *
56 to 46 *
56
46
60
50
NOTE 1 - *Decreases with the logarithm of the frequency.
NOTE 2 - Emission Level dB (μV/m) = 20 log Emission Level (μV/m)
NOTE 3 - The tighter limit applies at the band edges.
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
3.4
FCC ID: 2AOTTXIR
Page 9 of 137
Operating Condition of EUT
3.4.1 Setup the EUT as shown in Sec. 3.2.
3.4.2 Turn on the power of all equipment.
3.4.3 Turn the EUT on the test mode, and then test.
3.5
Test Procedures
The EUT was placed upon a non-metallic table, which is 0.8 m above the
horizontal conducting ground plane and 0.4 m from a vertical reference plane.
The EUT was connected to the power mains through an Artificial Mains
Network (AMN) to provide a 50 Ω coupling impedance for the measuring
equipment. Both sides of AC line (Line & Neutral) were checked to find out the
maximum conducted emission according to FCC Part 15 Subpart C and ANSI
C63.10: 2013 requirements during conducted disturbance test.
The I.F. bandwidth of Test Receiver ESCI was set at 9 kHz.
The frequency range from 150 kHz to 30 MHz was checked.
Test with a dummy load in lieu of the antenna to determine compliance with
Section 15.207 limits within the transmitter's fundamental emission band.
(According to KDB 174176 D01 Line Conducted FAQ)
3.6
Test Results

The frequency and amplitude of the highest conducted emission relative the
limit is reported. All the emissions not reported below are too low against the
FCC limit.
Worst case emission:
Frequency
No. Operation
Modulation
Channel
Data Page
(MHz)
1.
BT DH1
00
2402
P10
2.
BT 3DH1
00
2402
P11
Transmitting
P12
3.
BT DH5
00
2402
P13
3.
BT 3DH5
00
2402
P14
4.
Receiving
BT
--NOTE 1 – Level = Read Level + AMN Factor + Cable Loss
NOTE 2 – “QP” means “Quasi-Peak” values
NOTE 3 – The emission levels which not reported are too low against the
official limit.
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
Page 10 of 137
FCC ID: 2AOTTXIR
Worst case emission
EUT
Console
Temperature :
Model No.
XIR
Test Mode
Transmitting
Humidity
22℃
Date of Test :
51%RH
2018.03.24
BT DH1:
AMN
Meter
Frequency
Reading Factor
Polarization
(MHz)
dB (μV) (dB/m)
0.5112
31.3
10.34
0.5112
25.6
10.34
0.537
32.3
10.34
0.537
26.5
10.34
0.9135
23.7
10.32
0.9135
17.9
10.32
Line
2.001
20.1
10.32
2.001
14
10.32
8.414
24.41
10.31
8.414
17.21
10.31
22.6
22.99
10.12
22.6
14.39
10.12
0.5201
28.6
10.33
0.5201
21.3
10.33
0.5316
28.8
10.33
0.5316
22.1
10.33
0.9092
19.3
10.32
0.9092
13.3
10.32
Neutral
2.489
14
10.33
2.489
8.3
10.33
7.444
19.51
10.33
7.444
13.31
10.33
23.08
23.6
10.18
23.08
15.1
10.18
Cable Emission Limits
Margin
Loss Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
0.05
41.69
56
14.31
QP
0.05
35.99
46
10.01 Average
0.05
42.69
56
13.31
QP
0.05
36.89
46
9.11 Average
0.07
34.09
56
21.91
QP
0.07
28.29
46
17.71 Average
0.09
30.51
56
25.49
QP
0.09
24.41
46
21.59 Average
0.17
34.89
60
25.11
QP
0.17
27.69
50
22.31 Average
0.29
33.4
60
26.6
QP
0.29
24.8
50
25.2 Average
0.05
38.98
56
17.02
QP
0.05
31.68
46
14.32 Average
0.05
39.18
56
16.82
QP
0.05
32.48
46
13.52 Average
0.07
29.69
56
26.31
QP
0.07
23.69
46
22.31 Average
0.1
24.43
56
31.57
QP
0.1
18.73
46
27.27 Average
0.16
30
60
30
QP
0.16
23.8
50
26.2 Average
0.29
34.07
60
25.93
QP
0.29
25.57
50
24.43 Average
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 11 of 137
BT DH5:
AMN
Meter
Frequency
Reading Factor
Polarization
(MHz)
dB (μV) (dB/m)
0.4644
30
10.35
0.4644
23.7
10.35
0.5358
32
10.34
0.5358
26.3
10.34
0.9074
23.9
10.32
0.9074
17.7
10.32
Line
1.579
21.4
10.32
1.579
15.8
10.32
8.426
25.01
10.31
8.426
17.31
10.31
23.04
23.5
10.11
23.04
14.7
10.11
0.5046
28
10.33
0.5046
21.7
10.33
0.531
28.9
10.33
0.531
22
10.33
0.9091
19.5
10.32
0.9091
13
10.32
Neutral
3.481
14.9
10.34
3.481
9.4
10.34
9.381
19.9
10.32
9.381
13.8
10.32
23.32
24
10.18
23.32
15.2
10.18
Cable Emission Limits
Margin
Loss Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
0.05
40.4
56.61
16.21
QP
0.05
34.1
46.61
12.51 Average
0.05
42.39
56
13.61
QP
0.05
36.69
46
9.31 Average
0.07
34.29
56
21.71
QP
0.07
28.09
46
17.91 Average
0.08
31.8
56
24.2
QP
0.08
26.2
46
19.8 Average
0.17
35.49
60
24.51
QP
0.17
27.79
50
22.21 Average
0.29
33.9
60
26.1
QP
0.29
25.1
50
24.9 Average
0.05
38.38
56
17.62
QP
0.05
32.08
46
13.92 Average
0.05
39.28
56
16.72
QP
0.05
32.38
46
13.62 Average
0.07
29.89
56
26.11
QP
0.07
23.39
46
22.61 Average
0.11
25.35
56
30.65
QP
0.11
19.85
46
26.15 Average
0.18
30.4
60
29.6
QP
0.18
24.3
50
25.7 Average
0.29
34.47
60
25.53
QP
0.29
25.67
50
24.33 Average
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 12 of 137
BT 3DH1:
AMN
Meter
Frequency
Reading Factor
Polarization
(MHz)
dB (μV) (dB/m)
0.5088
31.4
10.34
0.5088
26.2
10.34
0.5341
31.9
10.34
0.5341
26.4
10.34
0.9111
23.6
10.32
0.9111
18
10.32
Line
2.702
19.31
10.32
2.702
14.11
10.32
9.115
24.9
10.31
9.115
17.5
10.31
23.11
23.6
10.11
23.11
14.9
10.11
0.5072
28.3
10.33
0.5072
22
10.33
0.5317
28.8
10.33
0.5317
22.1
10.33
0.9146
19.4
10.32
0.9146
13.2
10.32
Neutral
2.774
14.31
10.33
2.774
9.01
10.33
8.915
19.7
10.32
8.915
13.9
10.32
23.08
23.7
10.18
23.08
15.3
10.18
Cable Emission Limits
Margin
Loss Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
0.05
41.79
56
14.21
QP
0.05
36.59
46
9.41 Average
0.05
42.29
56
13.71
QP
0.05
36.79
46
9.21 Average
0.07
33.99
56
22.01
QP
0.07
28.39
46
17.61 Average
0.1
29.73
56
26.27
QP
0.1
24.53
46
21.47 Average
0.18
35.39
60
24.61
QP
0.18
27.99
50
22.01 Average
0.29
34
60
26
QP
0.29
25.3
50
24.7 Average
0.05
38.68
56
17.32
QP
0.05
32.38
46
13.62 Average
0.05
39.18
56
16.82
QP
0.05
32.48
46
13.52 Average
0.07
29.79
56
26.21
QP
0.07
23.59
46
22.41 Average
0.1
24.74
56
31.26
QP
0.1
19.44
46
26.56 Average
0.18
30.2
60
29.8
QP
0.18
24.4
50
25.6 Average
0.29
34.17
60
25.83
QP
0.29
25.77
50
24.23 Average
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
Page 13 of 137
FCC ID: 2AOTTXIR
BT 3DH5:
AMN
Meter
Frequency
Reading Factor
Polarization
(MHz)
dB (μV) (dB/m)
0.5128
30.6
10.34
0.5128
25.4
10.34
0.5357
32
10.34
0.5357
26.5
10.34
0.9346
22.3
10.32
0.9346
14.9
10.32
Line
1.59
22.5
10.32
1.59
16
10.32
8.846
25.1
10.31
8.846
17.8
10.31
23.69
23.9
10.11
23.69
15.2
10.11
0.5099
28.5
10.33
0.5099
22.2
10.33
0.5362
28.6
10.33
0.5362
22.6
10.33
0.9094
19.2
10.32
0.9094
13.2
10.32
Neutral
1.975
15
10.33
1.975
9.5
10.33
7.549
20.7
10.33
7.549
13.5
10.33
23.8
23.7
10.17
23.8
15.1
10.17
Cable Emission Limits
Margin
Loss Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
0.05
40.99
56
15.01
QP
0.05
35.79
46
10.21 Average
0.05
42.39
56
13.61
QP
0.05
36.89
46
9.11 Average
0.07
32.69
56
23.31
QP
0.07
25.29
46
20.71 Average
0.08
32.9
56
23.1
QP
0.08
26.4
46
19.6 Average
0.18
35.59
60
24.41
QP
0.18
28.29
50
21.71 Average
0.29
34.3
60
25.7
QP
0.29
25.6
50
24.4 Average
0.05
38.88
56
17.12
QP
0.05
32.58
46
13.42 Average
0.05
38.98
56
17.02
QP
0.05
32.98
46
13.02 Average
0.07
29.59
56
26.41
QP
0.07
23.59
46
22.41 Average
0.09
25.42
56
30.58
QP
0.09
19.92
46
26.08 Average
0.17
31.2
60
28.8
QP
0.17
24
50
26
Average
0.29
34.16
60
25.84
QP
0.29
25.56
50
24.44 Average
TEST ENGINEER: Jarey
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
Page 14 of 137
FCC ID: 2AOTTXIR
EUT
Console
Model No.
XIR
Test Mode
Receiving
Temperature :
Humidity
22℃
Date of Test :
51%RH
2018.03.24
BT:
Polarization
Line
Neutral
AMN
Meter
Frequency
Reading Factor
(MHz)
dB (μV) (dB/m)
0.5117
31.2
10.34
0.5117
25.8
10.34
0.5384
32.2
10.34
0.5384
26.5
10.34
0.9088
23.8
10.32
0.9088
18
10.32
3.281
18.3
10.33
3.281
13.3
10.33
8.97
25.3
10.31
8.97
17.9
10.31
23.48
24
10.11
23.48
15.2
10.11
0.5114
28.6
10.33
0.5114
22
10.33
0.5316
29
10.33
0.5316
22.1
10.33
0.9092
19.3
10.32
0.9092
12.8
10.32
2.004
14.9
10.33
2.004
8.7
10.33
8.155
19.5
10.33
8.155
13.3
10.33
23.33
23.8
10.18
23.33
15.3
10.18
Cable Emission Limits
Margin
Loss Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
0.05
41.59
56
14.41
QP
0.05
36.19
46
9.81 Average
0.05
42.59
56
13.41
QP
0.05
36.89
46
9.11 Average
0.07
34.19
56
21.81
QP
0.07
28.39
46
17.61 Average
0.11
28.74
56
27.26
QP
0.11
23.74
46
22.26 Average
0.18
35.79
60
24.21
QP
0.18
28.39
50
21.61 Average
0.29
34.4
60
25.6
QP
0.29
25.6
50
24.4 Average
0.05
38.98
56
17.02
QP
0.05
32.38
46
13.62 Average
0.05
39.38
56
16.62
QP
0.05
32.48
46
13.52 Average
0.07
29.69
56
26.31
QP
0.07
23.19
46
22.81 Average
0.09
25.32
56
30.68
QP
0.09
19.12
46
26.88 Average
0.17
30
60
30
QP
0.17
23.8
50
26.2 Average
0.29
34.27
60
25.73
QP
0.29
25.77
50
24.23 Average
TEST ENGINEER: Jarey
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
Page 15 of 137
FCC ID: 2AOTTXIR
4 RADIATED EMISSION MEASUREMENT
4.1
Test Equipment
The following test equipment are used during the radiated emission test in a
semi-anechoic chamber:
Item
1.
2.
Manufacturer
Agilent
HP
Model No. Serial No.
Last Cal.
Next Cal.
8447D 2944A06664 Apr 27, 2017 Apr 26, 2018
8449B
3008A00864 Mar 8, 2018 Mar 7, 2019
Agilent
N9010A MY52221182 Jun 12, 2017 Jun 11, 2018
4.
Type
Preamplifier
Preamplifier
Spectrum
Analyzer
Test Receiver
5.
Bi-log Antenna
Schwarz beck
6.
7.
Horn Antenna
Horn Antenna
EMCO
EMCO
ESCI
VULB
9168
3115
3116
8.
Software
Audix
E3
3.
4.2
R&S
101303
May 07, 2017 May 06, 2018
708
Jul 20, 2017 Jul 19, 2018
9607-4878 Jun 02, 2017 Jun 01, 2018
00062643 Sep 08, 2017 Sep 08, 2019
SET00200
--9912M295-2
Block Diagram of Test Setup
4.2.1 Below 1GHz
ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS
EUT
3.0 METERS
FRP TABLE
0.8 m
GROUND PLANE
PREAMPLIFIER
TEST RECEIVER
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
Page 16 of 137
FCC ID: 2AOTTXIR
4.2.2 Above 1GHz
ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS
BORESIGHT ANTENNA TOWER
EUT
3.0 METERS
1.5 m
PREAMPLIFIER
4.3
SPECTRUM ANALYZER
Radiated Emission Limit (§15.209)
Frequency
(MHz)
30 ~
88 ~
216 ~
Above
Distance
(m)
88
216
960
960
Field strength limits (μV/m)
(μV/m)
100
150
200
500
dB(μV/m)
40.0
43.5
46.0
54.0
NOTE 1 - Emission Level dB (μV/m) = 20 log Emission Level (μV/m)
NOTE 2 - The tighter limit applies at the band edges.
NOTE 3 - Distance refers to the distance in meters between the measuring
instrument antenna and the closed point of any part of the device or
system.
NOTE 4 - The limits shown are based on Quasi-peak value detector below or
equal to 1GHz and Average value detector above 1GHz.
NOTE 5 - Above 1 GHz, the limit on peak emission is 20 dB above the maximum
permitted average emission limit applicable to the EUT
4.4
Test Configuration
The EUT (listed in Sec.2.1) and the simulators (listed in Sec.2.2) were installed
as shown on Sec.4.2 to meet FCC requirements and operating in a manner that
tends to maximize its emission level in a normal application.
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
4.5
FCC ID: 2AOTTXIR
Page 17 of 137
Operating Condition of EUT
4.5.1 Setup the EUT as shown in Sec. 4.2.
4.5.2 Turn on the power of all equipment.
4.5.3 Turn the EUT on the test mode, and then test.
4.6
Test Procedures
Radiated emission test applies to harmonics/spurs that fall in the restricted
bands listed in Section 15.205. The maximum permitted average field strength
is listed in Section 15.209. A pre-amp is necessary for this measurement. For
measurement above 1 GHz, set RBW = 1MHz, VBW = 10 Hz, Sweep: Auto. If
the emission is pulsed, modify the unit for continuous operation; use the
settings shown above, then correct the reading by subtracting the peak-average
correction factor, derived from the appropriate duty cycle calculation.
The EUT was placed on a turntable. Below 1 GHz, the table height is 80 cm
above the reference ground plane. Above 1 GHz, the table height is 1.5 m. The
turntable rotated 360 degrees to determine the position of the maximum
emission level. The EUT was set 3 meters away from the receiving antenna,
which was mounted on an antenna tower. The antenna moved up and down
between 1 meter and 4 meters to find out the maximum emission level.
Broadband antenna (Calibrated Bi-log Antenna) or Horn antenna was used as
receiving antenna. Both horizontal and vertical polarizations of the antenna
were set on measurement. In order to find the maximum emission, all of the
interference cables were manipulated according to ANSI C63.10: 2013
requirements during radiated emission test.
The bandwidth of Test Receiver R&S ESCI was set at 120 kHz from 30MHz to
1000MHz.
The bandwidth of the VBW was set at 1MHz and RBW was set at 1MHz for
peak emission measurement above 1GHz and 1MHz RBW, 10Hz VBW for
average emission above 1GHz for Spectrum Agilent N9010A.
The frequency range from 30 MHz to 25 GHz (Up to 10th harmonics from
fundamental frequency) was checked.
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
4.7
Page 18 of 137
FCC ID: 2AOTTXIR
Test Results

The frequency and amplitude of the highest radiated emission relative the limit
is reported. All the emissions not reported below are too low against the FCC
limit.
Frequency range: below 1G (Worst case emission)
No.
1.
2.
3.
4.
5.
Operation
Transmitting
Receiving
Modulation
Channel
BT DH1
BT DH5
BT 3DH1
BT 3DH5
BT
00
00
00
00
00
Frequency
(MHz)
2402
2402
2402
2402
2402
Data Page
P20
P20
P21
P21
P22
Frequency range: above 1G
No.
Operation
1.
2.
3.
4.
5.
6.
7.
8.
9.
Transmitting
10.
11.
12.
13.
14.
15.
16.
17.
18.
19. Receiving
Modulation
BT DH1
BT DH3
BT DH5
BT 3DH1
BT 3DH3
BT 3DH5
BT
Restricted Frequency bands:
No. Operation
Modulation
1.
BT DH1
2.
BT DH3
3.
BT DH5
Transmitting
4.
BT 3DH1
5.
BT 3DH3
6.
BT 3DH5
Channel
00
39
78
00
39
78
00
39
78
00
39
78
00
39
78
00
39
78
--
Frequency
(MHz)
2402
2441
2480
2402
2441
2480
2402
2441
2480
2402
2441
2480
2402
2441
2480
2402
2441
2480
--
Channel
Frequency
Cabinet Emission
Cabinet Emission
Cabinet Emission
Cabinet Emission
Cabinet Emission
Cabinet Emission
Audix Technology (Shanghai) Co., Ltd.
Data Page
P23
P23
P24
P24
P25
P25
P26
P26
P27
P27
P28
P28
P29
P29
P30
P30
P31
P31
P32
Data Page
P33
P34
P34
P35
P35
P36
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Additional Radiated emission (Mixed worst modulation): below 1G
No. Operation
Modulation
Channel
Frequency
AP6210: 802.11b
2412 MHz
1. Transmitting AP6210: BT 3DH5
00
2402 MHz
WLT2564M: BLE
39
2480 MHz
Additional Radiated emission (Mixed worst modulation): above 1G
No. Operation
Modulation
Channel
Frequency
AP6210: 802.11b
2412 MHz
1. Transmitting AP6210: BT 3DH1
39
2441 MHz
WLT2564M: BT
39
2480 MHz
Page 19 of 137
Data Page
P37
Data Page
P37
NOTE 1 – Level = Read Level + Antenna Factor + Cable Loss - Preamp Factor
NOTE 2 – “QP” means “Quasi-Peak” values
NOTE 3 – 0°was the table front facing the antenna. Degree is calculated from
0°clockwise facing the antenna.
NOTE 4 – The emission levels which not reported are too low against the
official limit.
NOTE 5 – The emission levels recorded below is data of EUT configured in
Lying direction, for Lying direction was the maximum emission
direction during the test. The data of Side & Standing direction are
too low against the official limit to be reported.
NOTE 6 – All reading are Quasi-Peak values below or equal to 1GHz, Peak and
Average values above 1GHz.
For above 1GHz test, if the peak measured value complies with the
average limit, it is unnecessary to perform an average measurement.
NOTE 7 – The frequency range 2310-2390MHz & 2483.5-2500MHz were
tested for Restricted bands.
NOTE 8 – The EUT with AP6210 and WLT2564M can transmit at the same
time. The Additional Radiated emission (Mixed worst modulation) is
tested for the simultaneous radiated spurious emission.
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
Page 20 of 137
FCC ID: 2AOTTXIR
Worst case emission < 1GHz
EUT
Console
Model No.
XIR
Test Mode
Transmitting
Temperature :
Humidity
22℃
Date of Test :
51%RH
2018.03.28
BT DH1:
Meter Antenna
Frequency
Reading Factor
Polarization
(MHz)
dB (μV) (dB/m)
155.91
7.98
19.36
191.745
15.95
16.24
239.147
22.35
17.72
Horizontal
287.99
10.17
18.82
333.687
9.24
20.47
612.064
4.83
25.64
30.531
12.85
18.86
61.346
8.79
19.01
80.362
13.93
14.28
Vertical
119.436
12.04
17.44
239.147
12.26
17.72
625.078
5.48
25.82
Cable
Loss
(dB)
1.31
1.46
1.61
1.74
1.87
2.53
0.55
0.78
0.86
1.12
1.61
2.55
Emission Limits
Level dB
dB
(μV/m) (μV/m)
28.65
43.5
33.65
43.5
41.68
46
30.73
46
31.58
46
33
46
32.26
40
28.58
40
29.07
40
30.6
43.5
31.59
46
33.85
46
Cable
Loss
(dB)
0.81
1.31
1.46
1.61
1.87
2.64
0.56
0.79
0.87
1.13
1.61
2.55
Emission Limits
Level dB
dB
(μV/m) (μV/m)
21.45
40
25.65
43.5
34.07
43.5
41.75
46
31.91
46
32.41
46
32.06
40
29.32
40
31.57
40
29.5
43.5
32.6
46
33.75
46
Margin
(dB)
Remark
14.85
9.85
4.32
15.27
14.42
13
7.74
11.42
10.93
12.9
14.41
12.15
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
Margin
(dB)
Remark
18.55
17.85
9.43
4.25
14.09
13.59
7.94
10.68
8.43
14
13.4
12.25
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
BT DH5:
Meter Antenna
Frequency
Reading Factor
Polarization
(MHz)
dB (μV) (dB/m)
67.913
2.55
18.09
155.91
4.98
19.36
191.745
16.37
16.24
Horizontal
239.147
22.42
17.72
333.687
9.57
20.47
672.845
3.28
26.49
30.853
12.61
18.89
63.313
9.81
18.72
82.071
16.57
14.13
Vertical
120.277
10.85
17.52
239.147
13.27
17.72
625.078
5.38
25.82
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
Page 21 of 137
FCC ID: 2AOTTXIR
BT 3DH1:
Meter Antenna
Frequency
Reading Factor
(MHz)
dB (μV) (dB/m)
68.872
2.39
17.96
166.651
6.17
18.96
191.745
16.23
16.24
Horizontal
239.147
22.25
17.72
287.99
10.53
18.82
672.845
4.4
26.49
30.745
13.35
18.88
63.092
9.1
18.75
80.644
14.15
14.25
Vertical
121.976
10.6
17.59
287.99
10.06
18.82
601.427
4.09
25.69
Polarization
Cable
Loss
(dB)
0.81
1.35
1.46
1.61
1.74
2.64
0.56
0.79
0.86
1.14
1.74
2.52
Emission Limits
Level dB
dB
(μV/m) (μV/m)
21.16
40
26.48
43.5
33.93
43.5
41.58
46
31.09
46
33.53
46
32.79
40
28.64
40
29.26
40
29.33
43.5
30.62
46
32.3
46
Cable
Loss
(dB)
0.82
1.29
1.46
1.61
1.74
2.5
0.56
0.79
0.86
1.12
1.74
2.64
Emission Limits
Level dB
dB
(μV/m) (μV/m)
21.34
40
25.88
43.5
33.93
43.5
41.96
46
31.15
46
32.18
46
32.42
40
29.37
40
28.86
40
29.39
43.5
31.53
46
31.53
46
Margin
(dB)
Remark
18.84
17.02
9.57
4.42
14.91
12.47
7.21
11.36
10.74
14.17
15.38
13.7
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
Margin
(dB)
Remark
18.66
17.62
9.57
4.04
14.85
13.82
7.58
10.63
11.14
14.11
14.47
14.47
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
BT 3DH5:
Meter Antenna
Frequency
Reading Factor
(MHz)
dB (μV) (dB/m)
69.357
2.62
17.9
151.067
5.54
19.05
191.745
16.23
16.24
Horizontal
239.147
22.63
17.72
287.99
10.59
18.82
599.321
3.98
25.7
30.853
12.97
18.89
63.759
9.92
18.66
80.927
13.77
14.23
Vertical
119.018
10.89
17.38
287.99
10.97
18.82
672.845
2.4
26.49
Polarization
TEST ENGINEER: Jarey
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
Page 22 of 137
FCC ID: 2AOTTXIR
EUT
Console
Model No.
XIR
Test Mode
Receiving
Temperature :
Humidity
22℃
Date of Test :
51%RH
2018.03.28
BT:
Meter Antenna
Frequency
Reading Factor
Polarization
(MHz)
dB (μV) (dB/m)
69.357
1.91
17.9
151.067
4.91
19.05
191.745
16.26
16.24
Horizontal
239.147
22.49
17.72
287.99
11.16
18.82
672.845
3.33
26.49
31.18
13
18.92
62.871
8.56
18.79
81.212
14.48
14.2
Vertical
120.277
11.23
17.52
287.99
10.27
18.82
597.223
2.46
25.64
Cable
Loss
(dB)
0.82
1.29
1.46
1.61
1.74
2.64
0.56
0.79
0.87
1.13
1.74
2.5
Emission Limits
Level dB
dB
(μV/m) (μV/m)
20.63
40
25.25
43.5
33.96
43.5
41.82
46
31.72
46
32.46
46
32.48
40
28.14
40
29.55
40
29.88
43.5
30.83
46
30.6
46
Margin
(dB)
Remark
19.37
18.25
9.54
4.18
14.28
13.54
7.52
11.86
10.45
13.62
15.17
15.4
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
TEST ENGINEER: Jarey
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
Page 23 of 137
FCC ID: 2AOTTXIR
Radiated Emission > 1GHz
EUT
Console
Model No.
XIR
Test Mode
Transmitting
Temperature :
Humidity
22℃
Date of Test :
51%RH
2018.03.30
BT DH1: CH00 (2402 MHz):
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
1398.336 43.79
25.42
3.9
1899.636 43.13
27.46
4.52
2930.633 42.43
30.28
5.67
Horizontal
4845.948 38.23
34.08
7.66
7242.052 39.38
37.45
9.14
10636.85 37.94
39.05
11.06
1406.443 43.38
25.46
3.9
2018.511 42.42
27.84
4.64
3280.326 39.69
31.2
6.06
Vertical
5392.918 37.82
34.67
8.06
7390.07
38.68
37.65
9.28
10423.8
37.89
38.95
10.86
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.87
37.24
74
36.76
Peak
35.38
39.73
74
34.27
Peak
35.21
43.17
74
30.83
Peak
33.94
46.03
74
27.97
Peak
35.45
50.52
74
23.48
Peak
35.49
52.56
74
21.44
Peak
35.86
36.88
74
37.12
Peak
35.3
39.6
74
34.4
Peak
34.89
42.06
74
31.94
Peak
34.02
46.53
74
27.47
Peak
35.53
50.08
74
23.92
Peak
35.42
52.28
74
21.72
Peak
BT DH1: CH39 (2441 MHz):
Meter Antenna Cable
Frequency
Reading Factor
Polarization
Loss
(MHz)
dB (μV) (dB/m) (dB)
1414.597 43.42
25.5
3.92
1921.727 42.74
27.53
4.55
2973.293 42.02
30.42
5.71
Horizontal
4916.49
37.97
34.14
7.72
7497.646 38.04
37.8
9.34
10484.23
37.6
38.98
10.96
1422.798 43.11
25.54
3.92
2036.09
41.32
27.88
4.68
3347.371 38.92
31.36
6.11
Vertical
5455.631
36.9
34.75
8.11
7541.114 37.83
37.88
9.34
10545.01 36.53
39.01
10.96
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.85
36.99
74
37.01
Peak
35.37
39.45
74
34.55
Peak
35.2
42.95
74
31.05
Peak
33.92
45.91
74
28.09
Peak
35.61
49.57
74
24.43
Peak
35.44
52.1
74
21.9
Peak
35.84
36.73
74
37.27
Peak
35.3
38.58
74
35.42
Peak
34.81
41.58
74
32.42
Peak
34.04
45.72
74
28.28
Peak
35.64
49.41
74
24.59
Peak
35.47
51.03
74
22.97
Peak
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 24 of 137
BT DH1: CH78 (2480 MHz):
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
1431.047 43.41
25.58
3.92
1883.236 43.04
27.4
4.49
2913.74
41.92
30.23
5.63
Horizontal
4776.419 37.62
34.03
7.59
7347.474 38.94
37.6
9.21
10423.8
37.13
38.95
10.86
1394.3
42.96
25.4
3.9
2053.822
41.5
27.92
4.68
3252.005 39.33
31.13
6.01
Vertical
5599.412 37.12
34.88
8.22
7221.15
38.04
37.42
9.14
10822.92 37.13
39.12
11.15
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.83
37.08
74
36.92
Peak
35.4
39.53
74
34.47
Peak
35.21
42.57
74
31.43
Peak
33.96
45.28
74
28.72
Peak
35.52
50.23
74
23.77
Peak
35.42
51.52
74
22.48
Peak
35.88
36.38
74
37.62
Peak
35.29
38.81
74
35.19
Peak
34.92
41.55
74
32.45
Peak
34.09
46.13
74
27.87
Peak
35.43
49.17
74
24.83
Peak
35.55
51.85
74
22.15
Peak
BT DH3: CH00 (2402 MHz)
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
1390.276 42.77
25.38
3.87
1866.977 42.62
27.34
4.49
2896.945 41.48
30.18
5.63
Horizontal
5031.499 37.83
34.24
7.79
7096.999
37.9
37.25
9.08
10215.02 36.69
38.82
10.76
1358.498 42.73
25.22
3.84
1966.68
42.24
27.69
4.58
3415.787 38.56
31.52
6.16
Vertical
5503.143 37.74
34.8
8.11
7096.999 37.82
37.25
9.08
10215.02 36.95
38.82
10.76
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.88
36.14
74
37.86
Peak
35.41
39.04
74
34.96
Peak
35.21
42.08
74
31.92
Peak
33.91
45.95
74
28.05
Peak
35.36
48.87
74
25.13
Peak
35.36
50.91
74
23.09
Peak
35.92
35.87
74
38.13
Peak
35.33
39.18
74
34.82
Peak
34.75
41.49
74
32.51
Peak
34.06
46.59
74
27.41
Peak
35.36
48.79
74
25.21
Peak
35.36
51.17
74
22.83
Peak
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 25 of 137
BT DH3: CH39 (2441 MHz):
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
1354.577 43.47
25.2
3.84
1792.937 42.65
27.08
4.4
3150.237 40.03
30.88
5.9
Horizontal
4721.515
37.9
33.98
7.52
7829.86
38.19
38.41
9.54
10980.47 37.47
39.19
11.25
1456.081 42.17
25.7
3.98
2114.052 41.79
28.05
4.76
3177.672 38.64
30.95
5.9
Vertical
5830.64
37.38
35.07
8.32
6914.763 37.31
36.96
8.96
9952.717 36.75
38.71
10.57
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.92
36.59
74
37.41
Peak
35.48
38.65
74
35.35
Peak
35.03
41.78
74
32.22
Peak
33.98
45.42
74
28.58
Peak
35.8
50.34
74
23.66
Peak
35.59
52.32
74
21.68
Peak
35.8
36.05
74
37.95
Peak
35.29
39.31
74
34.69
Peak
35
40.49
74
33.51
Peak
34.15
46.62
74
27.38
Peak
35.21
48.02
74
25.98
Peak
35.31
50.72
74
23.28
Peak
BT DH3: CH78 (2480 MHz):
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
1319.794 43.46
25.02
3.78
1834.878 42.36
27.23
4.46
2847.139 42.13
30.01
5.59
Horizontal
5119.517 37.14
34.35
7.84
7650.888 37.92
38.09
9.41
10010.42 36.84
38.7
10.67
1490.142 42.93
25.86
4.01
2169.767 41.19
28.16
4.84
3105.037 38.49
30.77
5.85
Vertical
5730.396 36.97
34.99
8.27
7695.244 38.32
38.17
9.41
10698.51
37.6
39.08
11.06
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.96
36.3
74
37.7
Peak
35.44
38.61
74
35.39
Peak
35.21
42.52
74
31.48
Peak
33.94
45.39
74
28.61
Peak
35.7
49.72
74
24.28
Peak
35.3
50.91
74
23.09
Peak
35.77
37.03
74
36.97
Peak
35.28
38.91
74
35.09
Peak
35.08
40.03
74
33.97
Peak
34.12
46.11
74
27.89
Peak
35.72
50.18
74
23.82
Peak
35.51
52.23
74
21.77
Peak
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 26 of 137
BT DH5: CH00 (2402 MHz):
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
1342.882 43.58
25.14
3.81
1955.344
42.3
27.65
4.58
2806.288 41.59
29.88
5.55
Horizontal
4640.339 37.95
33.92
7.46
7562.942
38.2
37.92
9.34
9809.916 36.31
38.74
10.53
1378.273
43
25.32
3.87
2077.705 42.05
27.97
4.72
3078.229 38.82
30.7
5.8
Vertical
5932.638 36.84
35.15
8.43
7829.86
38.3
38.41
9.54
10948.78
36.7
39.17
11.25
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.93
36.6
74
37.4
Peak
35.34
39.19
74
34.81
Peak
35.22
41.8
74
32.2
Peak
34
45.33
74
28.67
Peak
35.64
49.82
74
24.18
Peak
35.32
50.26
74
23.74
Peak
35.89
36.3
74
37.7
Peak
35.29
39.45
74
34.55
Peak
35.11
40.21
74
33.79
Peak
34.18
46.24
74
27.76
Peak
35.8
50.45
74
23.55
Peak
35.58
51.54
74
22.46
Peak
BT DH5: CH39 (2441 MHz):
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
1378.273 42.95
25.32
3.87
1989.55
41.74
27.76
4.61
3051.653 39.71
30.64
5.8
Horizontal
5209.075 37.89
34.45
7.95
7015.42
38.13
37.13
9.01
10126.82 37.15
38.77
10.67
1520.598 42.27
25.99
4.07
2220.523 41.62
28.27
4.92
3495.691 37.34
31.7
6.26
Vertical
5284.902 36.51
34.55
7989.893 37.01
38.7
9.61
9838.312 36.24
38.73
10.53
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.89
36.25
74
37.75
Peak
35.31
38.8
74
35.2
Peak
35.14
41.01
74
32.99
Peak
33.97
46.32
74
27.68
Peak
35.3
48.97
74
25.03
Peak
35.33
51.26
74
22.74
Peak
35.74
36.59
74
37.41
Peak
35.27
39.54
74
34.46
Peak
34.67
40.63
74
33.37
Peak
33.99
45.07
74
28.93
Peak
35.89
49.43
74
24.57
Peak
35.32
50.18
74
23.82
Peak
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 27 of 137
BT DH5: CH78 (2480 MHz):
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
1304.623 44.02
24.94
3.75
1813.786 43.44
27.15
4.43
3105.037 38.85
30.77
5.85
Horizontal
5269.649 37.62
34.53
7.95
7920.911 38.62
38.58
9.54
10822.92 37.33
39.12
11.15
1335.141 42.68
25.1
3.81
2194.998 41.81
28.22
4.88
3034.063 38.99
30.59
5.75
Vertical
5164.102 36.11
34.4
7.9
6795.879 37.49
36.74
8.9
11108.16 36.86
39.24
11.39
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.98
36.73
74
37.27
Peak
35.46
39.56
74
34.44
Peak
35.08
40.39
74
33.61
Peak
33.99
46.11
74
27.89
Peak
35.84
50.9
74
23.1
Peak
35.55
52.05
74
21.95
Peak
35.94
35.65
74
38.35
Peak
35.28
39.63
74
34.37
Peak
35.15
40.18
74
33.82
Peak
33.95
44.46
74
29.54
Peak
35.09
48.04
74
25.96
Peak
35.61
51.88
74
22.12
Peak
BT 3DH1: CH00 (2402 MHz):
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
1282.193 44.67
24.82
3.72
2030.214 42.47
27.86
4.68
3214.623
40.2
31.04
5.95
Horizontal
5330.928 37.43
34.6
6934.778 37.08
36.99
8.96
9923.991 37.17
38.72
10.57
1327.446 42.76
25.06
3.78
2246.344 41.67
28.32
4.96
3556.843 38.64
31.83
6.31
Vertical
5104.741 37.06
34.33
7.84
8082.804 37.88
38.53
9.69
11302.48 37.61
39.32
11.52
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
36.01
37.2
74
36.8
Peak
35.3
39.71
74
34.29
Peak
34.96
42.23
74
31.77
Peak
34.01
46.02
74
27.98
Peak
35.23
47.8
74
26.2
Peak
35.31
51.15
74
22.85
Peak
35.95
35.65
74
38.35
Peak
35.27
39.68
74
34.32
Peak
34.61
42.17
74
31.83
Peak
33.93
45.3
74
28.7
Peak
35.86
50.24
74
23.76
Peak
35.63
52.82
74
21.18
Peak
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 28 of 137
BT 3DH1: CH39 (2441 MHz):
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
1477.276 43.18
25.8
4.01
2059.767 41.72
27.93
4.72
3177.672 38.84
30.95
5.9
Horizontal
4586.999 38.36
33.88
7.39
7200.309 38.64
37.39
9.14
11108.16 37.49
39.24
11.39
1289.627 43.43
24.86
3.72
1944.073 40.56
27.61
4.58
3629.54
38.01
31.98
6.41
Vertical
6018.999
37.3
35.24
8.43
7305.122 38.41
37.54
9.21
11400.91
37.7
39.36
11.66
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.78
37.21
74
36.79
Peak
35.29
39.08
74
34.92
Peak
35
40.69
74
33.31
Peak
34.01
45.62
74
28.38
Peak
35.42
49.75
74
24.25
Peak
35.61
52.51
74
21.49
Peak
36
36.01
74
37.99
Peak
35.35
37.4
74
36.6
Peak
34.54
41.86
74
32.14
Peak
34.22
46.75
74
27.25
Peak
35.49
49.67
74
24.33
Peak
35.64
53.08
74
20.92
Peak
BT 3DH1: CH78 (2480 MHz):
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
1267.454 44.14
24.74
3.69
2089.751 42.46
27.99
4.76
2782.06
42.23
29.8
5.51
Horizontal
5424.184 37.26
34.71
8.06
8013.02
38.31
38.66
9.61
9697.151 37.48
38.76
10.49
1278.492 43.31
24.8
3.72
2279.044 40.99
28.38
3671.746 38.26
32.06
6.41
Vertical
5031.499 37.16
34.24
7.79
7411.461 38.61
37.68
9.28
9725.221 35.69
38.76
10.53
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
36.03
36.54
74
37.46
Peak
35.29
39.92
74
34.08
Peak
35.22
42.32
74
31.68
Peak
34.03
46
74
28
Peak
35.9
50.68
74
23.32
Peak
35.33
51.4
74
22.6
Peak
36.01
35.82
74
38.18
Peak
35.27
39.1
74
34.9
Peak
34.5
42.23
74
31.77
Peak
33.91
45.28
74
28.72
Peak
35.55
50.02
74
23.98
Peak
35.33
49.65
74
24.35
Peak
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 29 of 137
BT 3DH3: CH00 (2402 MHz)
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
1490.142 43.26
25.86
4.01
1777.458 43.36
27.02
4.37
2742.143 42.43
29.66
5.47
Horizontal
5471.422 37.71
34.76
8.11
6894.806 37.69
36.92
8.96
9613.43
36.94
38.78
10.49
1538.281
42.7
26.07
4.07
2036.09
41.32
27.88
4.68
3366.778 38.27
31.41
6.11
Vertical
4973.662 37.76
34.18
7.72
7035.727 37.12
37.16
9.01
11667.6
37
39.27
11.79
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.77
37.36
74
36.64
Peak
35.49
39.26
74
34.74
Peak
35.22
42.34
74
31.66
Peak
34.05
46.53
74
27.47
Peak
35.18
48.39
74
25.61
Peak
35.34
50.87
74
23.13
Peak
35.72
37.12
74
36.88
Peak
35.3
38.58
74
35.42
Peak
34.8
40.99
74
33.01
Peak
33.91
45.75
74
28.25
Peak
35.31
47.98
74
26.02
Peak
35.67
52.39
74
21.61
Peak
BT 3DH3: CH39 (2441 MHz):
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
1516.21
43.18
25.98
4.04
1782.602
43.6
27.04
4.4
2922.174 41.48
30.26
5.67
Horizontal
4680.751 37.13
33.95
7.46
7138.144 37.87
37.3
9.08
10068.45 37.71
38.74
10.67
1569.721 42.33
26.2
4.13
1921.727 39.85
27.53
4.55
3735.978 37.75
32.19
6.52
Vertical
5060.668 37.02
34.27
7.84
7242.052 38.16
37.45
9.14
10274.24 36.98
38.86
10.76
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.74
37.46
74
36.54
Peak
35.49
39.55
74
34.45
Peak
35.21
42.2
74
31.8
Peak
33.99
44.55
74
29.45
Peak
35.39
48.86
74
25.14
Peak
35.32
51.8
74
22.2
Peak
35.68
36.98
74
37.02
Peak
35.37
36.56
74
37.44
Peak
34.44
42.02
74
31.98
Peak
33.92
45.21
74
28.79
Peak
35.45
49.3
74
24.7
Peak
35.38
51.22
74
22.78
Peak
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 30 of 137
BT 3DH3: CH78 (2480 MHz):
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
1473.013 43.05
25.78
3.98
1850.858 41.99
27.29
4.46
2863.645 42.41
30.07
5.59
Horizontal
5164.102 37.35
34.4
7.9
7497.646 38.04
37.8
9.34
10698.51 37.53
39.08
11.06
1300.858 42.42
24.92
3.75
2126.308 42.08
28.07
4.8
3396.098
38.7
31.47
6.16
Vertical
5551.069 37.23
34.84
8.16
7650.888 37.95
38.09
9.41
10393.71 37.38
38.93
10.86
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.79
37.02
74
36.98
Peak
35.42
38.32
74
35.68
Peak
35.21
42.86
74
31.14
Peak
33.95
45.7
74
28.3
Peak
35.61
49.57
74
24.43
Peak
35.51
52.16
74
21.84
Peak
35.98
35.11
74
38.89
Peak
35.29
39.66
74
34.34
Peak
34.77
41.56
74
32.44
Peak
34.07
46.16
74
27.84
Peak
35.7
49.75
74
24.25
Peak
35.41
51.76
74
22.24
Peak
BT 3DH5: CH00 (2402 MHz):
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
1358.498 43.49
25.22
3.84
1866.977 42.62
27.34
4.49
3252.005 38.93
31.13
6.01
Horizontal
5583.251 37.82
34.87
8.16
7284.038 38.24
37.51
9.21
10948.78 37.43
39.17
11.25
1315.985 42.28
25
3.78
2298.892
41.6
28.42
3141.145
38.4
30.86
5.9
Vertical
6106.616 37.67
35.41
8.48
7096.999 37.82
37.25
9.08
10514.58 37.34
39
10.96
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.92
36.63
74
37.37
Peak
35.41
39.04
74
34.96
Peak
34.92
41.15
74
32.85
Peak
34.08
46.77
74
27.23
Peak
35.48
49.48
74
24.52
Peak
35.58
52.27
74
21.73
Peak
35.96
35.1
74
38.9
Peak
35.27
39.75
74
34.25
Peak
35.04
40.12
74
33.88
Peak
34.32
47.24
74
26.76
Peak
35.36
48.79
74
25.21
Peak
35.46
51.84
74
22.16
Peak
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
Page 31 of 137
FCC ID: 2AOTTXIR
BT 3DH5: CH39 (2441 MHz):
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
1319.794 43.46
25.02
3.78
2107.95
41.44
28.03
4.76
2758.041 41.59
29.72
5.51
Horizontal
4973.662 37.58
34.18
7.72
7695.244 38.78
38.17
9.41
10333.8
37.07
38.89
10.86
1362.43
42.96
25.24
3.84
2006.877 41.58
27.81
4.64
3435.59
38.83
31.56
6.21
Vertical
5239.274 37.15
34.49
7.95
7898.049 37.18
38.54
9.54
10010.42 36.51
38.7
10.67
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.96
36.3
74
37.7
Peak
35.29
38.94
74
35.06
Peak
35.22
41.6
74
32.4
Peak
33.91
45.57
74
28.43
Peak
35.72
50.64
74
23.36
Peak
35.4
51.42
74
22.58
Peak
35.91
36.13
74
37.87
Peak
35.3
38.73
74
35.27
Peak
34.72
41.88
74
32.12
Peak
33.98
45.61
74
28.39
Peak
35.84
49.42
74
24.58
Peak
35.3
50.58
74
23.42
Peak
BT 3DH5: CH78 (2480 MHz):
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
1339.006 43.72
25.12
3.81
1905.135 42.49
27.48
4.52
3299.344 39.08
31.25
6.06
Horizontal
4653.771 37.67
33.93
7.46
8082.804 37.63
38.53
9.69
10423.8
37.13
38.95
10.86
1274.802
43.1
24.78
3.72
1983.808 40.65
27.74
4.61
3425.675 37.79
31.54
6.21
Vertical
5239.274 37.15
34.49
7.95
7200.309 37.54
37.39
9.14
11500.2
37.58
39.4
11.66
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.94
36.71
74
37.29
Peak
35.38
39.11
74
34.89
Peak
34.87
41.52
74
32.48
Peak
34
45.06
74
28.94
Peak
35.86
49.99
74
24.01
Peak
35.42
51.52
74
22.48
Peak
36.02
35.58
74
38.42
Peak
35.32
37.68
74
36.32
Peak
34.73
40.81
74
33.19
Peak
33.98
45.61
74
28.39
Peak
35.42
48.65
74
25.35
Peak
35.65
52.99
74
21.01
Peak
TEST ENGINEER: Jarey
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
Page 32 of 137
FCC ID: 2AOTTXIR
EUT
Console
Model No.
XIR
Test Mode
Receiving
Temperature :
Humidity
22℃
Date of Test :
51%RH
2018.03.30
BT:
Meter Antenna Cable
Frequency
Reading Factor
Loss
(MHz)
dB (μV) (dB/m) (dB)
1374.295 43.22
25.3
3.87
1883.236 43.04
27.4
4.49
2973.293 42.02
30.42
5.71
Horizontal
4902.3
38.28
34.12
7.66
7347.474 37.94
37.6
9.21
9530.432 36.73
38.79
10.45
1386.264
42.9
25.36
3.87
1983.808 40.65
27.74
4.61
3060.486 39.53
30.66
5.8
Vertical
5519.072 37.47
34.81
8.16
7454.429
38.2
37.74
9.28
10185.53 36.47
38.81
10.76
Polarization
Preamp Emission Limits
Margin
Factor Level dB
Remark
dB
(dB)
(dB)
(μV/m) (μV/m)
35.9
36.49
74
37.51
Peak
35.4
39.53
74
34.47
Peak
35.2
42.95
74
31.05
Peak
33.93
46.13
74
27.87
Peak
35.52
49.23
74
24.77
Peak
35.35
50.62
74
23.38
Peak
35.88
36.25
74
37.75
Peak
35.32
37.68
74
36.32
Peak
35.13
40.86
74
33.14
Peak
34.06
46.38
74
27.62
Peak
35.58
49.64
74
24.36
Peak
35.35
50.69
74
23.31
Peak
TEST ENGINEER: Jarey
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
Page 33 of 137
FCC ID: 2AOTTXIR
Emissions in restricted frequency bands:
EUT
Console
Model No.
XIR
Test Mode
Transmitting
Temperature :
Humidity
22℃
Date of Test :
51%RH
2018.03.28
BT DH1:
Meter Antenna Cable
Frequency
Reading Factor
Loss
(MHz)
dB (μV) (dB/m) (dB)
2315.394 38.56
28.45
5.04
2315.394 24.59
28.45
5.04
2355.115
38.1
28.53
5.08
2355.115 24.18
28.53
5.08
Horizontal
2485.865 38.38
28.77
5.23
2485.865 24.23
28.77
5.23
2493.962 37.72
28.79
5.23
2493.962 23.17
28.79
5.23
2317.711 38.67
28.46
5.04
2317.711 24.23
28.46
5.04
2355.508 38.46
28.53
5.08
2355.508 24.43
28.53
5.08
Vertical
2486.28
38.12
28.77
5.23
2486.28
24.15
28.77
5.23
2496.042 38.13
28.79
5.23
2496.042 25.24
28.79
5.23
Polarization
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.26
36.79
74
37.21
Peak
35.26
22.82
54
31.18 Average
35.26
36.45
74
37.55
Peak
35.26
22.53
54
31.47 Average
35.25
37.13
74
36.87
Peak
35.25
22.98
54
31.02 Average
35.25
36.49
74
37.51
Peak
35.25
21.94
54
32.06 Average
35.26
36.91
74
37.09
Peak
35.26
22.47
54
31.53 Average
35.26
36.81
74
37.19
Peak
35.26
22.78
54
31.22 Average
35.25
36.87
74
37.13
Peak
35.25
22.9
54
31.1 Average
35.25
36.9
74
37.1
Peak
35.25
24.01
54
29.99 Average
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 34 of 137
BT DH3:
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
2323.129 39.01
28.48
5.04
2323.129 25.33
28.48
5.04
2354.33
38.57
28.53
5.08
2354.33
24.34
28.53
5.08
Horizontal
2486.28
38.56
28.77
5.23
2486.28
24.35
28.77
5.23
2495.002 37.64
28.79
5.23
2495.002 23.55
28.79
5.23
2318.485
38.4
28.46
5.04
2318.485 24.42
28.46
5.04
2354.33
38.23
28.53
5.08
2354.33
25.25
28.53
5.08
Vertical
2486.073 38.55
28.77
5.23
2486.073 24.56
28.77
5.23
2497.916 37.73
28.8
5.23
2497.916 23.74
28.8
5.23
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.26
37.27
74
36.73
Peak
35.26
23.59
54
30.41 Average
35.26
36.92
74
37.08
Peak
35.26
22.69
54
31.31 Average
35.25
37.31
74
36.69
Peak
35.25
23.1
54
30.9 Average
35.25
36.41
74
37.59
Peak
35.25
22.32
54
31.68 Average
35.26
36.64
74
37.36
Peak
35.26
22.66
54
31.34 Average
35.26
36.58
74
37.42
Peak
35.26
23.6
54
30.4 Average
35.25
37.3
74
36.7
Peak
35.25
23.31
54
30.69 Average
35.25
36.51
74
37.49
Peak
35.25
22.52
54
31.48 Average
BT DH5:
Meter Antenna Cable
Frequency
Reading Factor
Polarization
Loss
(MHz)
dB (μV) (dB/m) (dB)
2318.098
38.2
28.46
5.04
2318.098 25.32
28.46
5.04
2356.097 38.34
28.54
5.08
2356.097 25.35
28.54
5.08
Horizontal
2487.317 38.24
28.77
5.23
2487.317 24.26
28.77
5.23
2496.251 38.13
28.79
5.23
2496.251 25.14
28.79
5.23
2322.548 38.31
28.48
5.04
2322.548 25.62
28.48
5.04
2353.544 38.56
28.53
5.08
2353.544 25.25
28.53
5.08
Vertical
2489.599 38.22
28.79
5.23
2489.599 25.23
28.79
5.23
2495.626 38.68
28.79
5.23
2495.626 24.26
28.79
5.23
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.26
36.44
74
37.56
Peak
35.26
23.56
54
30.44 Average
35.26
36.7
74
37.3
Peak
35.26
23.71
54
30.29 Average
35.25
36.99
74
37.01
Peak
35.25
23.01
54
30.99 Average
35.25
36.9
74
37.1
Peak
35.25
23.91
54
30.09 Average
35.26
36.57
74
37.43
Peak
35.26
23.88
54
30.12 Average
35.26
36.91
74
37.09
Peak
35.26
23.6
54
30.4 Average
35.25
36.99
74
37.01
Peak
35.25
24
54
30
Average
35.25
37.45
74
36.55
Peak
35.25
23.03
54
30.97 Average
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 35 of 137
BT 3DH1:
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
2322.354 38.57
28.48
5.04
2322.354 25.52
28.48
5.04
2361.801 39.03
28.54
5.08
2361.801 25.23
28.54
5.08
Horizontal
2488.354 38.59
28.77
5.23
2488.354 25.55
28.77
5.23
2497.916 38.46
28.8
5.23
2497.916 25.35
28.8
5.23
2320.612 38.12
28.46
5.04
2320.612 25.14
28.46
5.04
2357.079 38.35
28.54
5.08
2357.079 25.33
28.54
5.08
Vertical
2484.622 38.03
28.77
5.23
2484.622 24.37
28.77
5.23
2493.546 38.03
28.79
5.23
2493.546 25.18
28.79
5.23
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.26
36.83
74
37.17
Peak
35.26
23.78
54
30.22 Average
35.26
37.39
74
36.61
Peak
35.26
23.59
54
30.41 Average
35.25
37.34
74
36.66
Peak
35.25
24.3
54
29.7 Average
35.25
37.24
74
36.76
Peak
35.25
24.13
54
29.87 Average
35.26
36.36
74
37.64
Peak
35.26
23.38
54
30.62 Average
35.26
36.71
74
37.29
Peak
35.26
23.69
54
30.31 Average
35.25
36.78
74
37.22
Peak
35.25
23.12
54
30.88 Average
35.25
36.8
74
37.2
Peak
35.25
23.95
54
30.05 Average
BT 3DH3:
Meter Antenna Cable
Frequency
Reading Factor
Polarization
Loss
(MHz)
dB (μV) (dB/m) (dB)
2320.031 38.12
28.46
5.04
2320.031 25.32
28.46
5.04
2359.046 37.92
28.54
5.08
2359.046 24.63
28.54
5.08
Horizontal
2484.829 38.22
28.77
5.23
2484.829 25.35
28.77
5.23
2498.75
38.39
28.8
5.23
2498.75
25.35
28.8
5.23
2319.645
37.6
28.46
5.04
2319.645 24.23
28.46
5.04
2362.195 38.02
28.54
5.08
2362.195 25.23
28.54
5.08
Vertical
2485.243 37.71
28.77
5.23
2485.243 24.64
28.77
5.23
2495.002 38.29
28.79
5.23
2495.002 25.35
28.79
5.23
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.26
36.36
74
37.64
Peak
35.26
23.56
54
30.44 Average
35.26
36.28
74
37.72
Peak
35.26
22.99
54
31.01 Average
35.25
36.97
74
37.03
Peak
35.25
24.1
54
29.9 Average
35.25
37.17
74
36.83
Peak
35.25
24.13
54
29.87 Average
35.26
35.84
74
38.16
Peak
35.26
22.47
54
31.53 Average
35.26
36.38
74
37.62
Peak
35.26
23.59
54
30.41 Average
35.25
36.46
74
37.54
Peak
35.25
23.39
54
30.61 Average
35.25
37.06
74
36.94
Peak
35.25
24.12
54
29.88 Average
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 36 of 137
BT DH5:
Meter Antenna Cable
Frequency
Reading Factor
Loss
Polarization
(MHz)
dB (μV) (dB/m) (dB)
2316.552 38.07
28.46
5.04
2316.552 25.03
28.46
5.04
2357.866 38.33
28.54
5.08
2357.866 25.32
28.54
5.08
Horizontal
2487.939 37.92
28.77
5.23
2487.939 24.95
28.77
5.23
2495.418 38.92
28.79
5.23
2495.418 25.33
28.79
5.23
2321.386 38.24
28.46
5.04
2321.386 25.52
28.46
5.04
2358.456 38.29
28.54
5.08
2358.456 25.52
28.54
5.08
Vertical
2487.524 37.86
28.77
5.23
2487.524 24.66
28.77
5.23
2498.75
37.67
28.8
5.23
2498.75
24.33
28.8
5.23
Preamp Emission Limits
Margin
Factor Level dB
dB
Remark
(dB)
(dB)
(μV/m) (μV/m)
35.26
36.31
74
37.69
Peak
35.26
23.27
54
30.73 Average
35.26
36.69
74
37.31
Peak
35.26
23.68
54
30.32 Average
35.25
36.67
74
37.33
Peak
35.25
23.7
54
30.3 Average
35.25
37.69
74
36.31
Peak
35.25
24.1
54
29.9 Average
35.26
36.48
74
37.52
Peak
35.26
23.76
54
30.24 Average
35.26
36.65
74
37.35
Peak
35.26
23.88
54
30.12 Average
35.25
36.61
74
37.39
Peak
35.25
23.41
54
30.59 Average
35.25
36.45
74
37.55
Peak
35.25
23.11
54
30.89 Average
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
Page 37 of 137
FCC ID: 2AOTTXIR
Additional Radiated emission (Mixed worst modulation):
EUT
Console
Model No.
XIR
Test Mode
Transmitting
Temperature :
Humidity
22℃
Date of Test :
51%RH
2018.03.28
Below 1G
Meter Antenna Cable
Frequency
Reading Factor
Loss
(MHz)
dB (μV) (dB/m) (dB)
78.413
32.77
14.85
0.85
119.436
30.6
17.44
1.12
191.745
43.32
16.24
1.46
Horizontal
239.147
48.86
17.72
1.61
333.687
36.24
20.47
1.87
595.133
31.63
25.59
2.5
30.853
41.35
18.89
0.56
63.313
37.65
18.72
0.79
81.212
43.04
14.2
0.87
Vertical
120.277
38.46
17.52
1.13
239.147
39.62
17.72
1.61
625.078
33.26
25.82
2.55
Polarization
Preamp Emission Limits
Margin
Factor Level dB
Remark
dB
(dB)
(dB)
(μV/m) (μV/m)
27.77
20.7
40
19.3
Peak
27.49
21.67
43.5
21.83
Peak
26.94
34.08
43.5
9.42
Peak
26.86
41.33
46
4.67
Peak
26.98
31.6
46
14.4
Peak
28.2
31.52
46
14.48
Peak
27.93
32.87
40
7.13
Peak
27.83
29.33
40
10.67
Peak
27.76
30.35
40
9.65
Peak
27.48
29.63
43.5
13.87
Peak
26.86
32.09
46
13.91
Peak
28.17
33.46
46
12.54
Peak
Above 1G
Meter Antenna Cable
Frequency
Reading Factor
Polarization
Loss
(MHz)
dB (μV) (dB/m) (dB)
1289.627 43.49
24.86
3.72
2053.822 42.02
27.92
4.68
2656.331
42.3
29.37
5.39
Horizontal
5224.153 36.66
34.47
7.95
7497.646 38.04
37.8
9.34
10514.58 37.86
39
10.96
1547.199 42.41
26.11
4.1
2151.034 42.15
28.12
4.84
3270.858 38.45
31.18
6.01
Vertical
5361.833 37.04
34.64
8.06
7717.518 37.68
38.21
9.48
11302.48 37.61
39.32
11.52
Preamp Emission Limits
Margin
Factor Level dB
Remark
dB
(dB)
(dB)
(μV/m) (μV/m)
36
36.07
74
37.93
Peak
35.29
39.33
74
34.67
Peak
35.23
41.83
74
32.17
Peak
33.97
45.11
74
28.89
Peak
35.61
49.57
74
24.43
Peak
35.46
52.36
74
21.64
Peak
35.71
36.91
74
37.09
Peak
35.28
39.83
74
34.17
Peak
34.89
40.75
74
33.25
Peak
34.01
45.73
74
28.27
Peak
35.74
49.63
74
24.37
Peak
35.63
52.82
74
21.18
Peak
TEST ENGINEER: Jarey
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 38 of 137
5 20 DB BANDWIDTH MEASUREMENT
5.1
Test Equipment
The following test equipment was used during the Emission Bandwidth
measurement:
Item
Type
Manufacturer Model No. Serial No.
Last Cal.
Next Cal.
N9010A MY52221182 Jun 12, 2017 Jun 11, 2018
1. Spectrum Analyzer
Agilent
5.2
Block Diagram of Test Setup
Spectrum Analyzer
5.3
EUT
Specification Limits (§15.247(a)(1))
Frequency hopping systems shall have hopping channel carrier frequencies
separated by a minimum of 25 kHz or the 20 dB bandwidth of the hopping
channel, whichever is greater. Alternatively, frequency hopping systems
operating in the 2400-2483.5 MHz band may have hopping channel carrier
frequencies that are separated by 25 kHz or two-thirds of the 20 dB bandwidth
of the hopping channel, whichever is greater, provided the systems operate with
an output power no greater than 125 mW.
5.4
Operating Condition of EUT
The switch ON/OFF was used to enable the EUT to change the channel one by
one.
5.5
Test Procedure
The transmitter output was connected to the spectrum analyzer.
Use the following spectrum analyzer settings:
a) Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a
hopping channel
b) RBW ≥ 1% of the 20 dB bandwidth
c) VBW ≥ RBW
d) Sweep = auto
e) Detector function = peak
f) Trace = max hold
The 20 dB bandwidth is defined as the total spectrum the power of which is
lower than peak power minus 20 dB .
The test procedure is defined in FCC Public Notice DA 00-705, Mar.2000 (the
Procedure “ 20 dB Bandwidth” was used).
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
5.6
Page 39 of 137
FCC ID: 2AOTTXIR
Test Results
PASSED.
All the test results are attached in next pages.
(Test Date: 2018.03.23
Modulation
BT DH1
BT DH3
BT DH5
BT 3DH1
BT 3DH3
BT 3DH5
Temperature: 23℃
Channel
Humidity: 51 %)
Frequency 20dB Bandwidth
(MHz)
(MHz)
2/3 20dB
Bandwidth
(MHz)
00
2402
1.148
0.765
39
2441
1.147
0.765
78
2480
1.146
0.764
00
2402
1.162
0.775
39
2441
1.162
0.775
78
2480
1.161
0.774
00
2402
1.162
0.775
39
2441
1.162
0.775
78
2480
1.163
0.775
00
2402
1.158
0.772
39
2441
1.158
0.772
78
2480
1.158
0.772
00
2402
1.124
0.749
39
2441
1.124
0.749
78
2480
1.123
0.749
00
2402
1.112
0.741
39
2441
1.109
0.739
78
2480
1.106
0.737
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 40 of 137
BT DH1: CH00 (2402 MHz)
BT DH1: CH39 (2441 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 41 of 137
BT DH1: CH78 (2480 MHz)
BT DH3: CH00 (2402 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 42 of 137
BT DH3: CH39 (2441 MHz)
BT DH3: CH78 (2480 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 43 of 137
BT DH5: CH00 (2402 MHz)
BT DH5: CH39 (2441 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 44 of 137
BT DH5: CH78 (2480 MHz)
BT 3DH1: CH00 (2402 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 45 of 137
BT 3DH1: CH39 (2441 MHz)
BT 3DH1: CH78 (2480 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 46 of 137
BT 3DH3: CH00 (2402 MHz)
BT 3DH3: CH39 (2441 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 47 of 137
BT 3DH3: CH78 (2480 MHz)
BT 3DH5: CH00 (2402 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 48 of 137
BT 3DH5: CH39 (2441 MHz)
BT 3DH5: CH78 (2480 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 49 of 137
6 CARRIER FREQUENCY SEPARATION
MEASUREMENT
6.1
Test Equipment
The following test equipment was used during the Emission Bandwidth
measurement:
Item
Type
Manufacturer Model No. Serial No.
Last Cal.
Next Cal.
N9010A MY52221182 Jun 12, 2017 Jun 11, 2018
1. Spectrum Analyzer
Agilent
6.2
Block Diagram of Test Setup
Spectrum Analyzer
6.3
EUT
Specification Limits (§15.247(a)(1))
Frequency hopping systems shall have hopping channel carrier frequencies
separated by a minimum of 25 kHz or the 20 dB bandwidth of the hopping
channel, whichever is greater. Alternatively, frequency hopping systems
operating in the 2400-2483.5 MHz band may have hopping channel carrier
frequencies that are separated by 25 kHz or two-thirds of the 20 dB bandwidth
of the hopping channel, whichever is greater, provided the systems operate with
an output power no greater than 125 mW.
6.4
Operating Condition of EUT
The switch ON/OFF was used to enable the EUT to have its hopping function
enabled.
6.5
Test Procedure
The transmitter output was connected to the spectrum analyzer.
The EUT must have its hopping function enabled. Use the following spectrum
analyzer settings:
a) Span = wide enough to capture the peaks of two adjacent channels
b) RBW ≥ 1% of the span
c) VBW ≥ RBW
d) Sweep = auto
e) Detector function = peak
f) Trace = max hold
g) Allow the trace to stabilize. Use the marker-delta function to determine the
separation between the peaks of the adjacent channels. Submit this plot.
The test procedure is defined in FCC Public Notice DA 00-705, Mar.2000 (the
Procedure “ Carrier Frequency Separation” was used).
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
6.6
Page 50 of 137
FCC ID: 2AOTTXIR
Test Results
PASSED.
All the test results are attached in next pages.
(Test Date: 2018.03.23
Modulation
BT DH1
BT DH3
BT DH5
BT 3DH1
BT 3DH3
BT 3DH5
Temperature: 23℃
Humidity: 51 %)
Channel
Frequency
(MHz)
Separation
(MHz)
2/3 20dB
Bandwidth
(MHz)
00
2402
1.002
0.765
39
2441
0.999
0.765
78
2480
0.999
0.764
00
2402
1.002
0.775
39
2441
0.999
0.775
78
2480
0.999
0.774
00
2402
1.002
0.775
39
2441
0.999
0.775
78
2480
0.999
0.775
00
2402
0.999
0.772
39
2441
0.999
0.772
78
2480
1.002
0.772
00
2402
0.999
0.749
39
2441
1.002
0.749
78
2480
0.999
0.749
00
2402
1.002
0.741
39
2441
1.002
0.739
78
2480
0.999
0.737
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 51 of 137
BT DH1: CH00 (2402 MHz)
BT DH1: CH39 (2441 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 52 of 137
BT DH1: CH78 (2480 MHz)
BT DH3: CH00 (2402 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 53 of 137
BT DH3: CH39 (2441 MHz)
BT DH3: CH78 (2480 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 54 of 137
BT DH5: CH00 (2402 MHz)
BT DH5: CH39 (2441 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 55 of 137
BT DH5: CH78 (2480 MHz)
BT 3DH1: CH00 (2402 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 56 of 137
BT 3DH1: CH39 (2441 MHz)
BT 3DH1: CH78 (2480 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 57 of 137
BT 3DH3: CH00 (2402 MHz)
BT 3DH3: CH39 (2441 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 58 of 137
BT 3DH3: CH78 (2480 MHz)
BT 3DH5: CH00 (2402 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 59 of 137
BT 3DH5: CH39 (2441 MHz)
BT 3DH5: CH78 (2480 MHz)
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 60 of 137
7 NUMBER OF HOPPING FREQUENCIES
MEASUREMENT
7.1
Test Equipment
The following test equipment was used during the Emission Bandwidth
measurement:
Item
Type
Manufacturer Model No. Serial No.
Last Cal.
Next Cal.
N9010A MY52221182 Jun 12, 2017 Jun 11, 2018
1. Spectrum Analyzer
Agilent
7.2
Block Diagram of Test Setup
Spectrum Analyzer
7.3
EUT
Specification Limits (§15.247(a)(1)(iii))
Frequency hopping systems in the 2400-2483.5 MHz band shall use at least 15
channels.
7.4
Operating Condition of EUT
The switch ON/OFF was used to enable the EUT to have its hopping function
enabled.
7.5
Test Procedure
The transmitter output was connected to the spectrum analyzer.
The EUT must have its hopping function enabled. Use the following spectrum
analyzer settings:
a) Span = the frequency band of operation
b) RBW ≥ 1% of the span
c) VBW ≥ RBW
d) Sweep = auto
e) Detector function = peak
f) Trace = max hold
g) Allow the trace to stabilize. It may prove necessary to break the span up to
sections, in order to clearly show all of the hopping frequencies. Submit this
plot(s).
The test procedure is defined in FCC Public Notice DA 00-705, Mar.2000 (the
Procedure “ Number of Hopping Frequencies” was used).
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
7.6
Page 61 of 137
FCC ID: 2AOTTXIR
Test Results
PASSED.
All the test results are attached in next pages.
(Test Date: 2018.03.23
Temperature: 23℃
Humidity: 51 %)
Modulation
Number of Hopping Frequencies
BT DH1
79
BT DH3
79
BT DH5
79
BT 3DH1
79
BT 3DH3
79
BT 3DH5
79
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 62 of 137
BT DH1
BT DH3
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 63 of 137
BT DH5
BT 3DH1
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 64 of 137
BT 3DH3
BT 3DH5
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Johnson Industries (Shanghai) Co., Ltd.
FCC ID: 2AOTTXIR
Page 65 of 137
8 DWELL TIME MEASUREMENT
8.1
Test Equipment
The following test equipment was used during the Emission Bandwidth
measurement:
Item
Type
Manufacturer Model No. Serial No.
Last Cal.
Next Cal.
N9010A MY52221182 Jun 12, 2017 Jun 11, 2018
1. Spectrum Analyzer
Agilent
8.2
Block Diagram of Test Setup
Spectrum Analyzer
8.3
EUT
Specification Limits (§15.247(a)(1)(iii))
Frequency hopping systems in the 2400-2483.5 MHz band shall use at least 15
channels. The average time of occupancy on any channel shall not be greater
than 0.4 seconds within a period of 0.4 seconds multiplied by the number of
hopping channels employed.
8.4
Operating Condition of EUT
The switch ON/OFF was used to enable the EUT to have its hopping function
enabled.
8.5
Test Procedure
The transmitter output was connected to the spectrum analyzer.
The EUT must have its hopping function enabled. Use the following spectrum
analyzer settings:
a) Span = zero span, centered on a hopping channel
b) RBW = 1 MHz
c) VBW ≥ RBW
d) Sweep = as necessary to capture the entire dwell time per hopping channel
e) Detector function = peak
f) Trace = max hold
The test procedure is defined in FCC Public Notice DA 00-705, Mar.2000 (the
Procedure “ Time of Occupancy (Dwell Time)” was used).
Audix Technology (Shanghai) Co., Ltd.
Report No.: ACI-F18102
Download: XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Mirror Download [FCC.gov]XIR CONSOLE Test Report  JOHNSON INDUSTRIES (SHANGHAI) CO., LTD.
Document ID3839187
Application IDTMVRFreSx1ku0YAjGlyzbQ==
Document Description2AOTTXIR_Test Report-BT 2_Rev.1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize170.9kB (2136293 bits)
Date Submitted2018-05-04 00:00:00
Date Available2018-05-06 00:00:00
Creation Date2018-05-02 13:02:55
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2018-05-02 13:03:57
Document TitleTest Report

Source Exif Data [exif.tools]:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Modify Date                     : 2018:05:02 13:03:57+08:00
Create Date                     : 2018:05:02 13:02:55+08:00
Metadata Date                   : 2018:05:02 13:03:57+08:00
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:caeb919f-33f8-40ef-a415-3b62141b60ce
Instance ID                     : uuid:494e1b2a-d913-4ba5-af19-b51bcf106be0
Producer                        : Acrobat Distiller 7.0 (Windows)
Page Count                      : 65