FCC ID Device Details
| FCC ID | 2AZYA-A6PLUS |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AZYA |
| Product Code | A6PLUS |
| Applicant Business | Senwa Global International, S.A. de C.V. 🇲🇽 |
| Related Domains | |
| Equipment Class | smartphone |
| Test Firm | Shenzhen LGT Test Service Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2580-2610 MHz | Original Equipment | 2026-09-11 |
| 2412-2462 MHz | Original Equipment | 2026-09-11 |
| 2402-2480 MHz | Original Equipment | 2026-09-11 |
| 5745-5825 MHz | Original Equipment | 2026-09-11 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| user manual | Users Manual | 2026-09-11 | PDF 5.5 MB |
| Internal Photos | Internal Photos | 2026-09-11 | PDF 1.7 MB |
| External Photos | External Photos | 2026-09-11 | PDF 955.7 KB |
| Label and Information | ID Label/Location Info | 2026-09-11 | PDF 173.9 KB |
| Test Setup Photos | Test Setup Photos | 2026-09-11 | PDF 319 KB |
| Test Setup Photos | Test Setup Photos | 2026-09-11 | PDF 327.1 KB |
| Antenna Report | Test Report | 2026-09-11 | PDF 788.6 KB |
| Test Report | Test Report | 2026-09-11 | PDF 5.1 MB |
| Test Report | Test Report | 2026-09-11 | PDF 3.2 MB |
| Test Report | Test Report | 2026-09-11 | PDF 1.2 MB |
| Test Report | Test Report | 2026-09-11 | PDF 4 MB |
| Test Report | Test Report | 2026-09-11 | PDF 3.6 MB |
| Attestation Statements of US Agent for Service of Process, 2.911(d)(7) | Attestation Statements | 2026-09-11 | PDF 99.3 KB |
| Attestation of Covered Equipment, 2.911(d)(5)(i)(ii) | Attestation Statements | 2026-09-11 | PDF 112.2 KB |
| Agent Authorization Letter Template | Cover Letter(s) | 2026-09-11 | PDF 195.7 KB |
| Short & Long Term Confidentiality Request | Cover Letter(s) | 2026-09-11 | PDF 89.6 KB |
| Software Configuration Control Declaration | Cover Letter(s) | 2026-09-11 | PDF 95.3 KB |
| RF Exposure Report | RF Exposure Info | 2026-09-11 | PDF 4 MB |
| RF Exposure Report | RF Exposure Info | 2026-09-11 | PDF 868.1 KB |
| BLOCK Metadata only | Block Diagram | PDF 51.9 KB | |
| SCH Metadata only | Schematics | PDF 696.6 KB | |
| Operational Description Metadata only | Operational Description | PDF 968.9 KB | |
| SOFTWARE SECURITY REQUIREMENTS FOR U-NII DEVICES Metadata only | SDR Software/Security Info. | PDF 141.4 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 230 KB | |
| Tune-up Procedure Metadata only | Parts List/Tune Up Info | PDF 242.2 KB |
Application Information
| Application ID | weAbgqip7f7QmZPoPnjdTw== |
|---|---|
| Final Action Date | 2026-09-11 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0030939607 |
| Model | A6PLUS |
| Frequency Range | 2580-2610 MHz |
| Equipment Class | PCE - PCS Licensed Transmitter held to ear |
| Device Description | smartphone |
| Responsible Party | Roberto Fregoso, rfregoso@senwamobile.com |
| Technical Contact | Senwa Global International, S.A. de C.V., rfregoso@senwamobile.com |
| Non-Technical Contact | Yangyang Xu, HOPEK CORPORATION INC, HopekPeter@gmail.com |
| Test Firm | Wen Wen, Shenzhen LGT Test Service Co., Ltd., qa@lgt-cert.com |
| TCB Email | anezam@qai.org |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| weAbgqip7f7QmZPoPnjdTw== | 2026-09-11 | Original Equipment |
| dWBWWFZauxJsVRNgSn97lw== | 2026-09-11 | Original Equipment |
| M6MpZhtaG8p3gGzar/yWew== | 2026-09-11 | Original Equipment |
| Bl+mE89rJO0/oxhcAA3z4g== | 2026-09-11 | Original Equipment |
| 2jF2r6uzzosdk61E5KWBeg== | 2026-09-11 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules | Grant Notes |
|---|---|---|---|---|---|
| 824.2-848.8 MHz | 0.3034 | 2.5 PM | 250KGXW | 22H | |
| 824.2-848.8 MHz | 0.526 | 2.5 PM | 273KG7W | 22H | |
| 1850.2-1909.8 MHz | 0.5741 | 2.5 PM | 250KGXW | 24E | |
| 1850.2-1909.8 MHz | 0.3097 | 2.5 PM | 252KG7W | 24E | |
| 1852.4-1907.6 MHz | 0.3581 | 2.5 PM | 4M17F9W | 24E | |
| 1712.6-1752.4 MHz | 0.3404 | 2.5 PM | 4M16F9W | 27 | |
| 826.4-846.6 MHz | 0.113 | 2.5 PM | 4M17F9W | 22H | |
| 1860-1900 MHz | 0.2871 | 2.5 PM | 18M0G7D | 24E | |
| 1855-1905 MHz | 0.2877 | 2.5 PM | 9M00G7D | 24E | |
| 1860-1900 MHz | 0.26 | 2.5 PM | 18M0W7D | 24E | |
| 1720-1745 MHz | 0.1722 | 2.5 PM | 18M0G7D | 27 | |
| 1715-1750 MHz | 0.1734 | 2.5 PM | 9M01G7D | 27 | |
| 1720-1745 MHz | 0.1476 | 2.5 PM | 18M0W7D | 27 | |
| 1712.5-1752.5 MHz | 0.1556 | 2.5 PM | 4M52W7D | 27 | |
| 829-844 MHz | 0.0918 | 2.5 PM | 9M00G7D | 22H | |
| 829-844 MHz | 0.0789 | 2.5 PM | 9M00W7D | 22H | |
| 826.5-846.5 MHz | 0.0811 | 2.5 PM | 4M53W7D | 22H | |
| 2510-2560 MHz | 0.1596 | 2.5 PM | 18M0G7D | 27 | |
| 2505-2565 MHz | 0.1641 | 2.5 PM | 9M00G7D | 27 | |
| 2510-2560 MHz | 0.138 | 2.5 PM | 18M0W7D | 27 | |
| 2502.5-2567.5 MHz | 0.1439 | 2.5 PM | 4M52W7D | 27 | |
| 782 MHz | 0.0859 | 2.5 PM | 8M96G7D | 27 | |
| 782 MHz | 0.0662 | 2.5 PM | 8M96W7D | 27 | |
| 779.5-784.5 MHz | 0.074 | 2.5 PM | 4M51W7D | 27 | |
| 2580-2610 MHz | 0.2877 | 2.5 PM | 18M0G7D | 27 | |
| 2577.5-2612.5 MHz | 0.2985 | 2.5 PM | 13M5G7D | 27 | |
| 2580-2610 MHz | 0.3112 | 2.5 PM | 18M0W7D | 27 | |
| 2565-2615 MHz | 0.3311 | 2.5 PM | 9M01W7D | 27 | |
| 2310 MHz | 0.0287 | 2.5 PM | 8M98G7D | 27 | |
| 2310 MHz | 0.0322 | 2.5 PM | 9M02W7D | 27 | |
| 2307.5-2312.5 MHz | 0.0327 | 2.5 PM | 4M52W7D | 27 | |
| 2355 MHz | 0.0296 | 2.5 PM | 9M01G7D | 27 | |
| 2355 MHz | 0.0303 | 2.5 PM | 8M98W7D | 27 | |
| 2352.5-2357.5 MHz | 0.0337 | 2.5 PM | 4M51W7D | 27 | |
| 2506-2680 MHz | 0.2917 | 2.5 PM | 18M0G7D | 27 | |
| 2503.5-2682.5 MHz | 0.2999 | 2.5 PM | 13M5G7D | 27 | |
| 2506-2680 MHz | 0.3141 | 2.5 PM | 18M0W7D | 27 | |
| 2501-2685 MHz | 0.3228 | 2.5 PM | 9M04W7D | 27 | |
| 1720-1770 MHz | 0.2831 | 2.5 PM | 18M0G7D | 27 | |
| 1715-1775 MHz | 0.2877 | 2.5 PM | 9M01G7D | 27 | |
| 1720-1770 MHz | 0.2404 | 2.5 PM | 18M0W7D | 27 | |
| 1712.5-1777.5 MHz | 0.25 | 2.5 PM | 13M5W7D | 27 | |
| 2402-2480 MHz | 0.0003 | 15C | CC | ||
| 2412-2462 MHz | 0.0348 | 15C | CC | ||
| 15B | CC | ||||
| 2402-2480 MHz | 0.0023 | 15C | CC | ||
| 5180-5240 MHz | 0.043 | 15E | CC | ||
| 5260-5320 MHz | 0.0355 | 15E | CC ND | ||
| 5500-5700 MHz | 0.0385 | 15E | CC ND | ||
| 5745-5825 MHz | 0.0225 | 15E | CC |
Grants
TCB Grant - Application weAbgqip7f7QmZPoPnjdTw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 09/11/2026 Application Dated: 09/11/2026 |
| Senwa Global International, S.A. de C.V. |
| Av. Jose Maria Castorena 283 oficina 204 |
| Col. Cuajimalpa. C.P. 05320 |
| Ciudad de Mexico, Mexico |
| Attention: Roberto Fregoso , CTO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AZYA-A6PLUS |
| Name of Grantee: | Senwa Global International, S.A. de C.V. |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | smartphone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 0.3034 | 2.5 PM | 250KGXW | |
| 22H | 824.2 - 848.8 | 0.526 | 2.5 PM | 273KG7W | |
| 24E | 1850.2 - 1909.8 | 0.5741 | 2.5 PM | 250KGXW | |
| 24E | 1850.2 - 1909.8 | 0.3097 | 2.5 PM | 252KG7W | |
| 24E | 1852.4 - 1907.6 | 0.3581 | 2.5 PM | 4M17F9W | |
| 27 | 1712.6 - 1752.4 | 0.3404 | 2.5 PM | 4M16F9W | |
| 22H | 826.4 - 846.6 | 0.113 | 2.5 PM | 4M17F9W | |
| 24E | 1860.0 - 1900.0 | 0.2871 | 2.5 PM | 18M0G7D | |
| 24E | 1855.0 - 1905.0 | 0.2877 | 2.5 PM | 9M00G7D | |
| 24E | 1860.0 - 1900.0 | 0.26 | 2.5 PM | 18M0W7D | |
| 27 | 1720.0 - 1745.0 | 0.1722 | 2.5 PM | 18M0G7D | |
| 27 | 1715.0 - 1750.0 | 0.1734 | 2.5 PM | 9M01G7D | |
| 27 | 1720.0 - 1745.0 | 0.1476 | 2.5 PM | 18M0W7D | |
| 27 | 1712.5 - 1752.5 | 0.1556 | 2.5 PM | 4M52W7D | |
| 22H | 829.0 - 844.0 | 0.0918 | 2.5 PM | 9M00G7D | |
| 22H | 829.0 - 844.0 | 0.0789 | 2.5 PM | 9M00W7D | |
| 22H | 826.5 - 846.5 | 0.0811 | 2.5 PM | 4M53W7D | |
| 27 | 2510.0 - 2560.0 | 0.1596 | 2.5 PM | 18M0G7D | |
| 27 | 2505.0 - 2565.0 | 0.1641 | 2.5 PM | 9M00G7D | |
| 27 | 2510.0 - 2560.0 | 0.138 | 2.5 PM | 18M0W7D | |
| 27 | 2502.5 - 2567.5 | 0.1439 | 2.5 PM | 4M52W7D | |
| 27 | 782.0 - 782.0 | 0.0859 | 2.5 PM | 8M96G7D | |
| 27 | 782.0 - 782.0 | 0.0662 | 2.5 PM | 8M96W7D | |
| 27 | 779.5 - 784.5 | 0.074 | 2.5 PM | 4M51W7D | |
| 27 | 2580.0 - 2610.0 | 0.2877 | 2.5 PM | 18M0G7D | |
| 27 | 2577.5 - 2612.5 | 0.2985 | 2.5 PM | 13M5G7D | |
| 27 | 2580.0 - 2610.0 | 0.3112 | 2.5 PM | 18M0W7D | |
| 27 | 2565.0 - 2615.0 | 0.3311 | 2.5 PM | 9M01W7D | |
| 27 | 2310.0 - 2310.0 | 0.0287 | 2.5 PM | 8M98G7D | |
| 27 | 2310.0 - 2310.0 | 0.0322 | 2.5 PM | 9M02W7D | |
| 27 | 2307.5 - 2312.5 | 0.0327 | 2.5 PM | 4M52W7D | |
| 27 | 2355.0 - 2355.0 | 0.0296 | 2.5 PM | 9M01G7D | |
| 27 | 2355.0 - 2355.0 | 0.0303 | 2.5 PM | 8M98W7D | |
| 27 | 2352.5 - 2357.5 | 0.0337 | 2.5 PM | 4M51W7D | |
| 27 | 2506.0 - 2680.0 | 0.2917 | 2.5 PM | 18M0G7D | |
| 27 | 2503.5 - 2682.5 | 0.2999 | 2.5 PM | 13M5G7D | |
| 27 | 2506.0 - 2680.0 | 0.3141 | 2.5 PM | 18M0W7D | |
| 27 | 2501.0 - 2685.0 | 0.3228 | 2.5 PM | 9M04W7D | |
| 27 | 1720.0 - 1770.0 | 0.2831 | 2.5 PM | 18M0G7D | |
| 27 | 1715.0 - 1775.0 | 0.2877 | 2.5 PM | 9M01G7D | |
| 27 | 1720.0 - 1770.0 | 0.2404 | 2.5 PM | 18M0W7D | |
| 27 | 1712.5 - 1777.5 | 0.25 | 2.5 PM | 13M5W7D |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions are 0.94 W/kg, 0.86 W/kg, 0.86 W/kg and 1.53 W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. |
TCB Grant - Application M6MpZhtaG8p3gGzar/yWew==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 09/11/2026 Application Dated: 09/11/2026 |
| Senwa Global International, S.A. de C.V. |
| Av. Jose Maria Castorena 283 oficina 204 |
| Col. Cuajimalpa. C.P. 05320 |
| Ciudad de Mexico, Mexico |
| Attention: Roberto Fregoso , CTO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AZYA-A6PLUS |
| Name of Grantee: | Senwa Global International, S.A. de C.V. |
| Equipment Class: | Digital Transmission System |
| Notes: | smartphone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0003 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.0348 |
| Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions are 0.59 W/kg, 0.21 W/kg, 0.21 W/kg and 1.53 W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application dWBWWFZauxJsVRNgSn97lw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 09/11/2026 Application Dated: 09/11/2026 |
| Senwa Global International, S.A. de C.V. |
| Av. Jose Maria Castorena 283 oficina 204 |
| Col. Cuajimalpa. C.P. 05320 |
| Ciudad de Mexico, Mexico |
| Attention: Roberto Fregoso , CTO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AZYA-A6PLUS |
| Name of Grantee: | Senwa Global International, S.A. de C.V. |
| Equipment Class: | Part 15 Class B Computing Device Peripheral |
| Notes: | smartphone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | - |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application Bl+mE89rJO0/oxhcAA3z4g==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 09/11/2026 Application Dated: 09/11/2026 |
| Senwa Global International, S.A. de C.V. |
| Av. Jose Maria Castorena 283 oficina 204 |
| Col. Cuajimalpa. C.P. 05320 |
| Ciudad de Mexico, Mexico |
| Attention: Roberto Fregoso , CTO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AZYA-A6PLUS |
| Name of Grantee: | Senwa Global International, S.A. de C.V. |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | smartphone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0023 |
| Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions are 0.11 W/kg, 0.11 W/kg, 0.11 W/kg and 1.05 W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application 2jF2r6uzzosdk61E5KWBeg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 09/11/2026 Application Dated: 09/11/2026 |
| Senwa Global International, S.A. de C.V. |
| Av. Jose Maria Castorena 283 oficina 204 |
| Col. Cuajimalpa. C.P. 05320 |
| Ciudad de Mexico, Mexico |
| Attention: Roberto Fregoso , CTO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AZYA-A6PLUS |
| Name of Grantee: | Senwa Global International, S.A. de C.V. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | smartphone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.043 | ||
| CC ND | 15E | 5260.0 - 5320.0 | 0.0355 | ||
| CC ND | 15E | 5500.0 - 5700.0 | 0.0385 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.0225 |
| Power listed is the maximum conducted output power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, product specific (wireless router), and simultaneous transmission use conditions are 0.59 W/kg, 0.42 W/kg, 0.42 W/kg and 1.53 W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |